REED-Direct
Calibrator, Current -- CC-422
Product Description:
1/2" (13 mm) LCD display
Includes test leads
SPECIFICATIONS:
Range: 0 to 19.99 mA; 0 to 24.0 mA
Resolution: 0.01 mA; 0.1 mA
Sampling Time: 0.4 second
Dimensions: 7.3 x 3 x 1.5" (185 x 78 x 38mm)
Weight: 9.4 oz (265g)
Sold by
1 Supplier
REED-Direct
Calibrator, Loop -- VC05
Product Description:
0.02% accuracy and 0.001% of span display
Simulate mA and % of span display
Selectable step or ramp outputs
24V loop power supply
Includes test leads, allligator clips, protective holster, soft carrying case and batteries
SPECIFICATIONS:
Measurement Function
Voltage Range: -0.200 to 28.000V
Resolution: 1mV
Accuracy: ±0.02% rdg. ±2mV
Current Range: -1.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±4µA
Loop Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±4µA
Output Function
Current Range: 0.000 to 22.000mA
Resolution: 0.001mA
Accuracy: ±0.05% ±4µA
Loop Power Range: 24V
Accuracy: ±10%
Power Supply: Single 9V battery
Battery Life: Approx. 12 hours
Dimensions: 200 x 100 x 40mm
Weight: 550g
Sold by
1 Supplier
REED-Direct
Calibrator, Process -- VC25
Product Description:
Accurate to 0.02%
Simulates and reads 3 RTDs and 8 thermocouples
Measures 2 or 3-wire RTDs
Compatible with 32 pressure modules from 2.5kPa to 70MPa
24V loop power supply
Provides 25% or 100% step output for DC current either manually or automatically
Large 2-line LCD with whie LED backlight
User selectable auto power off
Includes test leads, soft carrying case and batteries
SPECIFICATIONS:
READ
DC Voltage Range: 50mV, 500mV, 5V, 50V
Accuracy: ±0.02% +10, ±0.02% +2, ±0.02% +5, ±0.03% +5
DC Current Range: 50mA
Accuracy: ±0.02% +2
Resistance Range: 500ω, 5kω
Accuracy: ±0.02% +0.1ω, ±0.02% +0.5ω
Frequency Range: 100Hz, 1kHz, 10kHz
Accuracy: ±2%
SOURCE
DC Voltage Range: 100mV, 1V, 10V
Accuracy: ±0.02% +10
DC Current Range: 20mA
Accuracy: ±0.02% +10
Resistance Range: 400ω, 4kω, 40kω
Accuracy: ±0.02% +0.1ω, ±0.05% +1ω, ±0.1% +10ω
Frequency Range: 100Hz, 1kHz, 10kHz, 100kHz
Accuracy: ±2%
FUNCTION/READ RANGE/ACC'Y/SOURCE RANGE/ACC'Y
Type R T/C/-40/1760°C/±1.5°
C/-40/1760°C/±1.2°C
Type S T/C/-20/1760°C/±1.5°
C/-20/1760°C/±1.5°C
Type K T/C/-200/950°C /±0.8°C/-200/1370°C /± 0.9°C
Type E T/C/-200/500°C/±1.5°
C/-200/1000°C/±0.5°C
Type J T/C/-200/700°C/±0.7°
C/-200/1200°C/± 0.7°C
Type T T/C -200/400°C/±0.7°C/-2
00/400°C/± 0.6°C
Type N T/C/-200/1000°C/±0.9
°C /-200/1300°C/± 0.8°C
Type B T/C/400/1800°C /±1.8°C/400/1800°C/±
1.1°C
Pt100 RTD/-200/700°C/±0.8°
C/-200/850°C/± 0.8°C
Pt1000 RTD/-200/630°C/±0.4°
C/-200/630°C/± 0.4°C
Cu50/-50/150°C/±0.7°
C/-50/150°C/±0.5°C
Sold by
1 Supplier
REED-Direct
Calibrator, Temperature -- CC-TEMPK
Product Description:
Instantly determine if your device needs calibration or if a sensor needs to be replaced
Complete with 9V battery, vinyl pouch case and 60" calibration cable terminated with subminiature connector
SPECIFICATIONS:
Temperature Ranges: 32°F (0°C), 212°F (100°C), 932°F (500°C), 1832°F (1000°C)
Accuracy: ±(0.25% + 1°F/°C)
Power Supply: Single 9V battery
Dimensions: 3.5 x 2.3 x 1" (89 x 58 x 25mm)
Weight: 10 oz (285g)
Sold by
1 Supplier
REED-Direct
Calibrator, Temperature -- VC01
Product Description:
6-digit LCD readout
Automatic calibration
User settable auto power off
Includes test leads with alligator clips, 9V battery, instruction manual and soft carrying case
SPECIFICATIONS
Voltage Range/Resolution: -10.00 to 110.00mV/0.01mV; -100.00 to 1100.0mV/0.1mV
Resistance Range/Resolution: 0.0 to 400.0_/0.1_
Thermocouple Range/Resolution:
R: -40 to 1760°C/1°C;
S: -20 to 1760°C/1°C;
B: 400 to 1800°C/1°C;
E: -200.0 to 1000.0°C/ 0.1°C;
K: -200.0 to 1370.0°C/0.1°C;
J: -200.0 to 1200.0°C/0.1°C;
T: -200.0 to 400.0°C/0.1°C;
N: -200.0 to 1300.0°C/0.1°C
Thermo-resistance Range/Resolution: Pt100: -200.0 to 850.0°C/0.1°C; Cu50: -50.0 to 150.0°C/0.1°C
Accuracy: ±0.05% setting value
Power Supply: Single 9V battery
Dimensions: 200 x 100 x 40mm
Weight: 550g
Sold by
1 Supplier
REED-Direct
Calibrator, Temperature -- VC14
Product Description:
Measure and source DC voltage, resistance, thermocouple and RTD temperature with a single unit
6-digit LCD readout with selectable backlight
Wave filter function
Includes set of industrial test leads, set of test probes with alligator clips, fuse, batteries, instruction manual and soft carrying case
SPECIFICATIONS:
Output Function
Voltage Range/Resolution: -10.000 to 110.000mV/10µV; -0.10000 to 1.10000V/0.01mV
Resistance Range/Resolution: 0.00 to 400.00?/00.1?
Thermocouple Range/Resolution:
R: -40 to 1760°C/1°C; S: -20 to 1760°C/1°C; B: 400 to 1800°C/1°C;
E: -200.0 to 1000.0°C/ 0.1°C;
K: -200.0 to 1370.0°C/0.1°C;
J: -200.0 to 1200.0°C/0.1°C;
T: -200.0 to 400.0°C/0.1°C;
N: -200.0 to 1300.0°C/0.1°C
Thermo-resistance Range/Resolution: Pt100: -200.0 to 850.0°C/0.1°C; Cu50: -50.0 to 150.0°C/0.1°C
MeasurementFunction
Voltage Range/Resolution: 0.00 to ±450.00mV/10µV
Resistance Range/Resolution: 0.00 to 450.00?/00.1?
Thermocouple & Thermo-resistance Range: Same as per Output Function
Sold by
1 Supplier
REED-Direct
Calibrator, Voltage/Current -- VC04
Product Description:
Accurate to 0.02%
Simulates and reads 3 RTDs and 8 thermocouples
Measures 2 or 3-wire RTDs
Compatible with 32 pressure modules from 2.5kPa to 70MPa
24V loop power supply
Provides 25% or 100% step output for DC current either manually or automatically
Large 2-line LCD with white LED backlight
User selectable auto power off
Includes test leads, allligator clips, protective holster, soft carrying case and batteries
SPECIFICATIONS:
READ
DC Voltage Range: 50mV, 500mV, 5V, 50V
Accuracy: ±0.02% +10, ±0.02% +2, ±0.02% +5, ±0.03% +5
DC Current Range: 50mA
Accuracy: ±0.02% +2
Resistance Range: 500?, 5k?
Accuracy: ±0.02% +0.1?, ±0.02% +0.5?
Frequency Range: 100Hz, 1kHz, 10kHz
Accuracy: ±2%
SOURCE
DC Voltage Range: 100mV, 1V, 10V
Accuracy: ±0.02% +10
DC Current Range: 20mA
Accuracy: ±0.02% +10
Resistance Range: 400?, 4k?, 40k?
Accuracy: ±0.02% +0.1?, ±0.05% +1?, ±0.1% +10?
Frequency Range: 100Hz, 1kHz, 10kHz, 100kHz
Accuracy: ±2%
FUNCTION / READ RANGE / ACC'Y / SOURCE RANGE / ACC'Y
Type R T/C / -40/1760°C / ±1.5°C / -40/1760°C / ±1.2°C
Type S T/C / -20/1760°C / ±1.5°C / -20/1760°C / ±1.5°C
Type K T/C / -200/950°C / ±0.8°C / -200/1370°C / ±0.9°C
Type E T/C / -200/500°C / ±1.5°C / -200/1000°C / ±0.5°C
Type J T/C / -200/700°C / ±0.7°C -/ 200/1200°C / ±0.7°C
Type T T/C / -200/400°C / ±0.7°C / -200/400°C / ±0.6°C
Type N T/C / -200/1000°C / ±0.9°C / -200/1300°C / ±0.8°C
Type B T/C / 400/1800°C / ±1.8°C / 400/1800°C / ±1.1°C
Pt100 RTD / -200/700°C / ±0.8°C / -200/850°C / ±0.8°C
Pt1000 RTD / -200/630°C / ±0.4°C / -200/630°C / ±0.4°C
Cu50 / -50/150°C ±0.7°C / -50/150°C / ±0.5°C
GENERAL
Continuity Test: Beep at ? 50?
Loop Power Supply: 24V ±10%
Power Supply: 4 x 1.5V "AA" alkaline batteries or 4 x 1.2V "AA" Ni-Hi batteries
Dimensions: 245 x 95 x 42mm
Weight: 500 g
Sold by
1 Supplier
REED-Direct
Calibrator, Voltage/Current -- VC15
Product Description:
Multiple input/output ranges for both DC voltage and current
24V loop power supply
6-digit LCD readout
Auto calibration
Auto power off
Includes test leads, allligator clips, protective holster, soft carrying case and batteries
SPECIFICATIONS:
Measurement/Source Functions
Voltage Range: 0.000 to 11.000V
Resolution: 1mV
Accuracy: ±0.02% rdg. ±0.01% range
Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±0.01% range
Loop Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±0.01% range
Source Functions
Analog Transducer Range: 0.000 to -22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% ±0.01% range
Loop Power Range: 24V
Accuracy: ±10%
Power Supply: Single 9V battery
Battery Life: Approx. 12 hours
Dimensions: 200 x 100 x 40mm
Weight: 550g with holster
Sold by
1 Supplier
REED-Direct
Calibrator, Voltage/Current, Dual Range -- CC-421
Product Description:
1/2" (13mm) LCD display
Includes test leads
SPECIFICATIONS:
Current Source: 0 to 24 mA (2 ranges)
Current Measure: 0 to 24 mA (2 ranges)
Voltage Source: -199.9 to +199.9 mV DC
Dimensions: 7.3 x 3 x 1.5" (185 x 78 x 38mm)
Weight: 9.4 oz (265g)
Sold by
1 Supplier
REED-Direct
Calibrator/Thermocouple Thermometer -- TC-920
Product Description:
Fahrenheit/Celsius selectable for temperature measurement and calibration
Large LCD display
Data hold
RS232 PC serial computer interface
Battery included
SPECIFICATIONS:
Temperature Range: -325 to 2246°F/-199 to 1230°C
Power Supply: Single 9V battery
Dimensions: 7.3 x 3.1 x 1.5" (185 x 78 x 38mm)
Weight: 9.9 oz (280g)
Sold by
1 Supplier
REED-Direct
Current Loop Simulator -- CC-MA
Product Description:
Simulates output ranges of 4 mA, 12 mA and 20 mA
Accurate to 0.1 mA
Overload indication when load exceeds 240ω
Compact case features push button output selector switch and bright red LEDs that indicate simulation output or battery status
Complete with 9V battery and calibration cable terminated with spade plugs
Dimensions/Weight: 89 x 58.4 x 25.4mm / 284g
Sold by
1 Supplier
REED-Direct
Dry Block Temperature Calibrator -- BX-150
Product Description:
Required temperature may be adjusted in 0.1° increments using front panel buttons
SPECIFICATIONS:
Temperature Range: 33 to 300°C (91.4 to 572°F)
Resolution: 0.1°C/°F
Accuracy: ±0.8°C (±1.6°F) <= 100°C (<= 212°F); ±1.6°C
(±3.2°F) 100-200°C (212-392°F); ±2.8°C
> 200°C (> 392°F)
Stability: ±0.1°C (±0.2°F) <=100°C (<=212°F); ±0.2°C
(±0.4°F) 100-200°C (212-392°F); ±0.4°C
(±0.8°F) >200°C (>392°F)
Time To Stability: 10 to 20 minutes
Heating Time: 30 min. to max.
Cooling Time: 30 min. to 100°C (212°F)
Power Supply: 110VAC (±10%), 2.5A
Well Depth: 90mm
Sold by
1 Supplier
REED-Direct
Infrared temperature Calibrator -- BX-500
Product Description:
Wide field of view to compensate for optical variations in individual infrared thermometers
Fixed emissivity of 0.95
Simply set the desired temperature in increments of 0.1°, wait for the calibrator to attain equilibrium, point the infrared thermometer at the target, and measure the radiated energy
Contact RTD reference well is located directly behind the blackbody target to assure even higher accuracies of ±0.1°C
SPECIFICATIONS:
Temperature Range: 50 to 500°C (122 to 932°F)
Resolution: 0.1°C (0.1°F)
Accuracy: ±0.8°C (±1.6°F): <=100°C (212°F); ±1.6°C (±3.2°F): 100 to <=200°C (212 to 392°F); ±2.8°C (±5.6°F): 200 to <=500°C (392 to <=932°F)
Stability: ±0.1°C (±0.2°F): <=100°C (212°F); ±0.2°C (±0.4°F): 100 to <=350°C (212 to 662°F); ±0.4°C (±0.8°F): 350 to <=500°C (662 to <=932°F)
Target Emissivity: Fixed at 0.95
Cooling Time: 45 minutes to 100°C (122°F)
Heating Time: 40 minutes to maximum
Aperture Diameter: 57mm
Power Supply: 220VAC (±10%), 1.25A/110VAC (±10%), 2.5A
Dimensions: 180 x 114 x 233mm
Weight: 3 kg
Sold by
1 Supplier
Calibration Instruments
Calibrator Style
Hand Held
Portable
Fixed
Modular
Battery Powered
Other Specific Calibration?
AC Voltage?
Must Not Have
Required
AC Voltage Range
From
To
Units
Reset
Apply
DC Voltage?
Must Not Have
Required
DC Voltage Range
From
To
Units
Reset
Apply
AC Current?
Must Not Have
Required
AC Current Range
From
To
Units
Reset
Apply
DC Current?
Must Not Have
Required
DC Current Range
From
To
Units
Reset
Apply
Signal / Waveform Generator Output?
Must Not Have
Required
Frequency Range
From
To
Units
Reset
Apply
Sine Wave?
Must Not Have
Required
Square Wave?
Must Not Have
Required
Triangular Wave?
Must Not Have
Required
Other Predefined?
Must Not Have
Required
Custom or User Defined?
Must Not Have
Required
Physical Properties
Acceleration / Vibration
Acoustic (Microphones)
Displacement / Position
Force / Load
Torque
Process, Environmental, Thermodynamic Properties
Conductivity / Dissolved Solids (in Aqueous Solutions)
Flow
Gas (Concentration)
Humidity / Moisture / Dew Point
ORP / Redox
pH
Pressure / Vacuum
Resistivity (in Aqueous Solutions)
Temperature
RTD, Thermistor
Thermocouple
Electrical Properties
Attenuator
Capacitance
Charge
Inductance
Power
Resistance/ Impedance
Display Type
Analog Meter or Indicator
Digital Readouts
Video Display Terminal
Local Interface
Analog Front Panel
Digital Front Panel
Computer Interface?
Must Not Have
Required
Interface Options
Serial Interface
Parallel Interface
Other Computer Interface
Application Software Included?
Must Not Have
Required
Traceable to a National or International Standard?
Must Not Have
Required
Operating Temperature
From
To
Units
Reset
Apply
REED-Direct
Supplier Profile
Show products from all suppliers