Description: OXYPLUS® is the oxygenation membrane capillary suitable for long-term oxygenation. As an integral asymmetric hollow fibre oxygenation membrane OXYPLUS combines the performance characteristics of OXYPHAN® with a dense outer skin characterizing it as a
- Geometry: Hollow Fiber
-
Description: CELGARD® is one of the world’s leading oxygenation membranes with high mechanical stability. CELGARD capillary membranes are produced by extrusion of Polypropylene. Consecutive anneal and stretch steps create the pores in the capillary wall. This production technology
- Geometry: Hollow Fiber
-
Description: CELGARD® is one of the world’s leading oxygenation membranes with high mechanical stability. CELGARD capillary membranes are produced by extrusion of Polypropylene. Consecutive anneal and stretch steps create the pores in the capillary wall. This production technology
- Geometry: Hollow Fiber
-
-
Description: exchange membranes. Moreover, a fully polymeric oxygenator without metal heat exchanger is easier to dispose and incinerate compliant to hygienic standards. HEXPET mats are available as single and double layer cross-wound mats. This unique design makes the capillaries adaptable to
- Geometry: Hollow Fiber
Find Suppliers by Category Top
Featured Products Top
-
integrated into the treatment scheme to produce superior effluent and achieve biological nutrient removal. The TITAN MEM-BOX™ comeswith integral hollow-fiber or flat-sheet membranes (depending upon the application). With S&L’s intuitive QUICKSMART™ PLC controls and plant (read more)
Browse Wastewater Treatment Equipment Datasheets for Smith & Loveless, Inc. -
), microfiltration (MF) and ultrafiltration (UF) applications Hollow Fiber Sealants ELANTAS’ patented polyurethane technology delivers outstanding heat and chemical resistance for extreme operating conditions (read more)
Browse Epoxy Adhesives Datasheets for ELANTAS North America LLC
More Information Top
-
Gas Transfer Performance of a Hollow Fiber Silicone Membrane Oxygenator: Ex Vivo Study
Abstract: Based on the results of in vitro studies of many experimental models, a silicone hollow fiber membrane oxygenator for pediatric cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber with a 300 μm outer …
-
Antibacterial Effect of Antibiotic Solution on Cellular Viability in Canine Veins
Abstract: An experimental silicone hollow fiber mem- brane oxygenator for long-term extracorporeal membrane oxygenation (ECMO) was developed in our laboratory us- ing an ultrathin silicone hollow fiber.
-
Relation Between Echinocytosis and Erythrocyte Calcium Content in Hemodialyzed Uremic Patients
Abstract: An experimental silicone hollow fiber mem- brane oxygenator for long-term extracorporeal membrane oxygenation (ECMO) was developed in our laboratory us- ing an ultrathin silicone hollow fiber.
-
http://www.atcs.jp/pdf/2002_8_5/268.pdf
Therefore, the development of a small, yet efficient, silicone hollow fiber membrane oxygenator for long- term ECMO usage was attempted.
-
Impact of Oxygenator Selection on Hemodynamic Energy Indicators Under Pulsatile and Nonpulsatile Flow in a Neonatal Extracorporeal Life Support Model
Just recently, we were able to use an FDA- approved pediatric hollow fiber membrane oxygen- ator in a clinical setting, and now we have a real option to use low-pressure drop oxygenators with FDA approval in the long term.
-
Abstracts from the Twenty‐Second Annual Meeting of the Japanese Society for Artificial Organs and Tissues November 9–10, 1984 Osaka, Japan
CLINICAL APPLICATION OF HOLLOW FIBER MEM- BRANE OXYGENATOR FOR OPEN HEART SURGERY.
-
Extracorporeal Membrane Oxygenator Compatible with Centrifugal Blood Pumps
A silicone rubber, hollow fiber membrane oxygenator that has a low blood flow resistance was developed and evaluated with centrifugal pumps.
-
http://repository.up.ac.za/bitstream/handle/2263/27835/00thesis.pdf?sequence=1
Force balance on fluid element in hollow fibre membrane oxygenator .
-
Computational evaluation of the thrombogenic potential of a hollow-fiber oxygenator with integrated heat exchanger during extracorporeal circulation
2011) A validated CFD model to predict O and CO transfer within hollow fiber membrane oxygenators .
-
Comparison of Perfusion Quality in Hollow‐Fiber Membrane Oxygenators for Neonatal Extracorporeal Life Support
Development and evaluation of a new hollow fiber membrane oxygenator .
Indicates content that may require registration and/or purchase.