-
Supplier: ASTM International
Description: applies to walls of masonry construction meeting the requirements of a “mass masonry wall” as defined herein. This guide does not apply to masonry walls that, by design, are intended to manage water as a barrier wall system or drainage wall system. 1.5 The
-
Supplier: ASTM International
Description: does not apply to the following: 1.4.1 Laminated products factory produced with a wood substrate, which are covered by Practice E2579. 1.4.2 Water-resistive barriers comprised of foam plastic materials contained within the wall system (see 5.3.1). 1.4.3 Water vapor retarders
-
Supplier: NuAire, Inc.
Description: Ergonomic Plastic Armrest Removable Work Tray Work Surface Support System Spill Trough with Drain Valve Two Duplex Outlet Back-wall One Service Valve Right Side Wall One Service Coupling Right Side Wall Two Service Couplings Left Side Wall Power Cord
- Inflow Velocity: 105 SFPM
-
-
Supplier: Epro Services, Inc.
Description: System III LW is a field installed composite waterproofing and gas vapor barrier that is comprised of a water-based Polymer Modified Asphalt (PMA) membrane applied to the back of a HDPE core and polypropylene fabric drainage composite which provides the durability and chemical
- Applications: Concrete, Floors, Foundations, Walls
- Form: Membrane/Sheeting
- Material: Polypropylene
-
Supplier: Polyguard Products, Inc.
Description: Poly Wall® Aluma Flash™ Plus is a 40-mil rubberized asphalt waterproofing sheet membrane, laminated to two layers of high strength polyethylene film, with a top protective layer of aluminum. The coating is supplied in rolls, with an easy to remove film release sheet, for easy application.
- Thickness: 0.04 inch
- Length / Height: 33.300000000000004 to 75 ft
- Width: 0.5 to 3 ft
- Material: Aluminum, Other, Polyethylene
-
Supplier: Polyguard Products, Inc.
Description: AIRLOK® Sheet UV 400 NP is a 40-mil, 36" x 75' self-adhesive, non-permeable composite sheet membrane, consisting of a foil/polyscrim film, laminated to a layer of rubberized-asphalt designed for air and moisture applications with a 1-year UV exposure. Rubberized-asphalt properties allow for
- Thickness: 0.04 inch
- Length / Height: 75 ft
- Width: 0.5 to 3 ft
- Material: Aluminum, Other, Polyethylene
-
Supplier: Epro Services, Inc.
Description: System III US is a field installed composite waterproofing system and gas vapor barrier system comprised of a water-based polymer modified asphalt (PMA) membrane either applied directly to HDPE drainage for blindside construction or the PMA is applied directly to the substrate that is
- Applications: Concrete, Floors, Foundations, Walls
- Form: Membrane/Sheeting
- Material: Polypropylene
-
Supplier: Polyguard Products, Inc.
Description: AIRLOK® Sheet 400 NP is a 40-mil, 36" x 75' laminated, modified-asphalt, self-adhesive, non-permeable sheet membranes bonded to a cross-laminated polyethylene sheet designed for air and moisture applications with a 60-day UV exposure. Rubberized-asphalt properties allow for self-sealing around
- Thickness: 0.04 inch
- Length / Height: 75 ft
- Width: 0.5 to 3 ft
- Applications: Building Wrap, Walls
-
Supplier: Polyguard Products, Inc.
Description: AIRLOK® Sheet 200 U/NP is a 28-mil, 36" x 100' laminated, butyl, self-adhesive, non-permeable sheet membrane bonded to a cross-laminated polyethylene sheet designed for air and moisture applications. It provides a 60-day UV exposure and with a service/performance temperature range up to 240°F. The
- Thickness: 0.028 inch
- Length / Height: 100 ft
- Width: 0.5 to 2.3333333333333335 ft
- Applications: Building Wrap, Walls
Find Suppliers by Category Top
Featured Products Top
-
extremely effective in reducing overall noise levels depending on the extent that the noise barrier blocks the sound path. The ideal situation would involve a full enclosure including 4 walls and a roof to eliminate the direct “line of sight”. Ventilation baffles, doors and windows (read more)
Browse Soundproofing and Acoustic Materials Datasheets for Isotech, Inc. -
seamless barrier that covers walls, ceilings, and irregular surfaces. Closed-cell spray foam delivers higher R-values and functions as a vapor barrier, while open-cell spray foam provides cost-effective coverage with lighter density. Because it is derived from polyurethane insulation foam (read more)
Browse Building Insulation Materials Datasheets for General Plastics Manufacturing Co. -
long-term thermal performance. Using a layered approach for storage tank insulation offers the best long-term stability, combining insulation, vapor barriers, and weatherproof cladding to protect the tank from moisture, UV exposure, and mechanical (read more)
Browse Insulation Jacketing Datasheets for Mid-Mountain Materials, Inc.
More Information Top
-
Residential Moisture Conditions—Facts and Experience
All homes except one had an interior wall vapor barrier of polyethylene film or kraft faced insulation batts.
-
Balk at Caulk - Guidelines for Repair of Joints in Historic Stone
In practice, however, there are many avenues for water to enter even the best laid masonry walls - driving rain, clogged gutters, poorly flashed utility connections, breaks in interior wall vapor barriers , etc.
-
Seasonal Variation in Airtightness of Two Detached Houses
Interior wall finish Vapor barrier .
-
Considerations for Controlling Condensation in High-Humidity Buildings: Lessons Learned
Partition walls are often problematic, since designers do not regularly design air and vapor barrier systems for interior walls .
-
Hygrothermal Performance of Timber-Framed External Walls in Finnish Climatic Conditions: A Method for Determining the Sufficient Water Vapour Resistance of the...
The study has been preceded by decades of discussion about the need of a vapour barrier in the interior wall lining of external wall assemblies.
-
Blower door tests of a group of identical flats in a new student accommodation in the Arctic - DTU Orbit
The reasons for such poor air tightness are lack of the installation gap between the vapour barrier and the inner wall, and insufficient connections of the vapour barrier to the interior walls as explained in the paper.
-
Energy and Environment Division, annual report FY 1980
The Rio, Wisconsin farmhouse had been retrofitted (storm windows, weatherstripping, and a vapor barrier on the inte- rior walls ).
-
Recommended Ventilation Strategies for Energy-Efficient Production Homes
If there is a vapor barrier on the interior wall surface, the wall can’t “dry to the inside” and i~ccumulated moisture may lead to rot (EDU 1996b).
-
Blower door tests of a group of identical flats in a new student accommodation in the Arctic - DTU Orbit
The reasons for such poor air tightness are lack of the installation gap between the vapour barrier and the inner wall, and insufficient connections of the vapour barrier to the interior walls as explained in the paper.
-
Moisture Measurements and Condensation Potential in Wood Frame Walls in a Hot-Humid Climate
ABSTRACT: It has long been noted that interior vapor barriers in wood frame walls in hot-humid climates can lead to interstitial condensation within walls.
Indicates content that may require registration and/or purchase.