Products/Services for VOC Vent Condenser
-
Condensers - (216 companies)Condensers are devices which accept a vapor stream and convert it to a liquid using heat transfer and/or compression.They are used in steam turbines for power plants, in cooling units for in-process fluids, and in air conditioning systems...Condenser TypeCondenser Application -
Laboratory Condensers - (39 companies)Laboratory condensers are large, coolant-filled tubes that surround smaller glass tubes that contain a hot fluid or vapor. They are used to cool fluids and condense gases. Laboratory condensers are used in distillation and reflux processes...
-
Volatile Organic Compounds (VOC) Analyzers - (41 companies)Volatile organic compound (VOC) analyzers are used to detect concentrations of heavy hydrocarbons in gas or liquid media. They can be used to detect alkanes, isoalkanes, cycloalkanes, alkenes and aromatics as well as benzene, toluene, xylenes... -
Roof Vents and Ventilators - (69 companies)Roof vents and ventilators are devices used to exhaust unwanted humidity or heat from below a building's roof. Roof vents and ventilators are used to ventilate the attic or crawlspace of a building, circulating air for cooling, and moisture...
-
Cores and Tubes - (39 companies)Cores and tubes are made of paper, plastic or metal and are used for mailing, shipping, material handling, and product display.
-
Foams and Foam Materials - (577 companies)Water-based and water-borne resins and latex materials do not contain volatile organic compounds (VOCs). Chemical systems for foams and foam materials include ethylene copolymer, expanded polyethylene, polycarbonate, polyester, polyether, polyetherimide...
-
Air Strippers - (43 companies)Air strippers are used to remove volatile organic compounds (VOCs), ammonia, hydrogen sulfide, and other contaminants from groundwater and wastewater. The Air stripping is a technology that uses an air stripper for VOC removal from ground water...
-
Thermal Oxidizers and Catalytic Oxidizers - (199 companies)Thermal oxidizers and catalytic oxidizers are used to destroy volatile organic compounds (VOC) in process gases. Thermal oxidizers may also be called afterburners or direct flame thermal oxidizers. Thermal oxidation is a method of pollution control...
-
Air Biofilters - (24 companies)Air biofilters use microorganisms to capture and biologically degrade air pollutants, such as VOCs and odors. Air biofilters are air pollution control devices that use microorganisms to capture and biologically degrade air pollutants...
-
Microscope Lenses and Objectives - (80 companies)Microscope lenses and microscope objectives include eyepieces or oculars, optical filters, objectives, adapters or mounts, condensers and other optical components for microscopy. Microscope lenses and microscope objectives include eyepieces...
Product News
-
Rosenberg USA
AC Axial Fans For Condenser Applications Four Rosenberg AC axial fans, complete with shrouds and finger guards for HVAC condenser applications, are now available for immediate shipment from Rosenberg USA. The fans feature profiled aluminum blades with winglet tips that reduce noise and improve fan performance. The fans include Rosenberg AKSD 500-mm and AKFD 560-mm, 630-mm and 800-mm models. They meet all requirements of the ErP Directive for fans to be used in the European Union. Maximum airflows range from 5,800 to 15,900 CFM at free... (read more)Browse HVAC Fans and Blowers Datasheets for Rosenberg USA -
Everlube Products
What are Low VOC Coatings? restrictions tighten,Everlube (R)Products continues to develop new and improved solid film lubricants to meet VOC restrictions,as well as REACH and RoHScompliance. *Our guaranteed shelf life for solid film lubricants is one year from the date of shipment when stored in a factory sealed containerbelow100?F. This ensures you have the maximum use time. *Our substantial product line offers a wide selection of solid film lubricants, many of which that are qualified to Military, OEM,and standard industrial... (read more)Browse Industrial Coatings Datasheets for Everlube Products -
Environics, Inc.
The Health Risks Associated with Exposure to VOCs Understanding VOC Gas and Its Impact on the Environment. Volatile Organic Compounds (VOCs) are a group of organic chemicals that exhibit a high vapor pressure at room temperature, meaning they can quickly evaporate into the surrounding air. They originate from numerous sources, including natural emissions and various human activities - even though there are well-documented health concerns associated with VOC exposure. This article dives into the origins and effects of VOC gas on the environment... (read more)Browse Manifolds and Manifold Systems Datasheets for Environics, Inc. -
Excelitas Technologies Corp.
Noblelight UV lamps reduce VOCs & downtime Noblelight UV lamps reduce VOC emissions and downtime. VOCs are released during the production of cast parts. These VOCs enter the environment in the exhaust air via an air duct or smokestack. Optimized low-pressure UV lamps clean and reduce pollutants in the foundry exhaust air by means of photo-oxidation. This was made possible by the joint development of a customized low-pressure UV lamp by xpuris and Excelitas Noblelight. Molds and cores for automotive industry castings are made from sand... (read more)Browse UV Lamps Datasheets for Excelitas Technologies Corp. -
Electro Optical Components, Inc.
Best, Highest Resolution Digital PIDs for VOCs We recognize that dealing with the analog output from PID sensors can present challenges. Now there is the new Digital PID sensor featuring UART and I2C outputs. This innovative product seamlessly replaces SemeaTech's 7-Smart Electrochemical Sensors for air quality monitoring (www.eoc-inc.com) . With this advancement, you can effortlessly monitor CO, SO2, NO2, NO, O3, NH3, H2S, and VOCs on a straightforward platform, easily swapping them out as required. If you're interested in sampling our... (read more)Browse Gas Sensors Datasheets for Electro Optical Components, Inc. -
Branch Environmental Solutions
Why Consider our Packaged System for VOC Control? Packaged Systems. For some applications on oxidizers, the destruction of the compound results in other chemicals which can still not be released to the atmosphere. For example, if you destroy a chlorinated organic, the final flue gas may contain HCl (Hydrochloric acid). If the quantity of HCl is significant, we can add a cooling system and a scrubber system to eliminate any acid emissions and convert the acid HCl to a neutral salt. Branch Environmental can provide the complete coordinated... (read more)Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
Everlube Products
Low VOC, thermally cured; solid film lubricant EsnalubeTM 382. Water Based, MoS2, Solid Film Lubricant. Esnalube 382 is a low VOC, thermally cured; MoS2 based solid film lubricant with a silicate binder system. This coating is designed to provide anti-seize and anti-galling properties in fastener related. applications. Esnalube 382 also provides an extremely low coefficient of friction, very good chemical resistance properties and performs best over a wide range of loads. Specifications for Esnalube 382. is approved/qualified to many... (read more)Browse Solid and Dry Film Lubricants Datasheets for Everlube Products -
Branch Environmental Solutions
VOC control with our Direct Thermal Oxidation to assure that you get good destruction efficiency. The actual temperature could be up to double the auto ignition temperature depending on the desired removal. Direct Oxidizers. With Direct Oxidizers, nothing additional is done except to allow the temperature to increase. This takes energy. If the inlet load of solvent or VOC is high enough, then this is the best way to approach control. Simply heat the gas. As the amount of solvent available decreases, the energy requirement... (read more)Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
Everlube Products
Low VOC MoS2 based solid film lubricant Everlube 9002. Water Based, MoS2 Solid Film Lubricant. Everlube 9002 is a low VOC MoS2 based solid film lubricant with a high molecular weight epoxy binder system. This coating provides excellent wear life, abrasion resistance, good chemical resistance, and performs the best in higher load carrying applications. Everlube 9002 is approved/qualified to many aerospace and industrial specification. Features / Benefits. Excellent wear life. Excellent abrasion resistance. Very good chemical... (read more)Browse Solid and Dry Film Lubricants Datasheets for Everlube Products -
Shenzhen Milvent Technology Co., Limited
Tiny Waterproof Vents Battery packs face risks of overheating, overpressure, and liquid ingress, which can compromise safety and cause costly failures. Engineers need reliable solutions that ensure both safety and operational stability in compact devices. Milvent Tiny Snap-In Vents provide critical protection and functionality: Explosion-proof venting safely releases high-pressure gas during abnormal conditions, preventing battery rupture. Waterproof and breathable membrane keeps water, dust, and other contaminants... (read more)Browse Plugs, Stoppers, and Inserts Datasheets for Shenzhen Milvent Technology Co., Limited
-
Bookshelf and Unified Agenda > Environmental Protection Agency > Office of Air Quality Planning and Standards > Emission Inventory Improvement Program - Techni...
VOC emission factor for loading of the distillation device or for the distillation column condenser vent (lb VOCs emitted/ton VOCs processed) QVOC .
-
Bookshelf and Unified Agenda > Environmental Protection Agency > Office of Compliance > Sector Notebooks > [FDBKF2003110613073148171] Profile of the Plastic Re...
Vents on condensers can be sources of VOC emissions.
-
States > Texas > State > Register > 2010 > [TexReg 2010-0820is] 08/20/2010
… b), and 63.654(g)(6), and Flexible Per mit Number 38754, SC Numbers 39 and 48, by failing to demonstrate compliance with a removal efficiency of 98% for volatile organic compounds ( VOC ) from the Steam Methane Reformer (SMR) con denser vent .
-
States > Wyoming > State > Regulations > Environmental Quality‚ Dept. of > Air Quality > [WY Regs deq/air - 8] 08 - Nonattainment Area Regulations
… from all dehydration units that are greater than or equal to 4 tpy, VOC emissions from all dehydration units shall be controlled to at least 98% manufacturer-designed VOC destruction efficiency and equipped with reboiler still vent condensers by January 1, 2017.
-
Federal Register > Monday, August 20, 2001 > [66 FR 43497] Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; VOC and NOX RACT Deter...
The following resin process systems shall be vented to the thermal oxidizer unit at all times when generating VOC emissions: (a) four reactor condenser vents , (b) five raw material weigh tanks, (c) four manual ejectors, (d) five mixers-resin thin down tanks …
-
http://repository.up.ac.za/bitstream/handle/2263/21784/Sahu_Optimum%282013%29.pdf?sequence=1
Significant reductions in VOC emissions can usually be achieved by controlling tank venting , condensers and purges and by thorough inspection and maintenance of gaskets and shaft seals.
-
Bookshelf and Unified Agenda > Environmental Protection Agency > Office of Compliance > Sector Notebooks > [FDBKF2003110613073147687] Profile of the Pharmaceut...
Condensers are widely used in the pharmaceutical industry to recover solvents from process operations (a process condenser ) and as air pollution control devices to remove VOCs from vented gases.
-
Field Testing Results for the R-BTEXTM Process for Controlling Glycol Dehydrator Emissions
Figure 2 shows an example of how the BTEX and other VOC emission rates will increase with condenser temperature for atypical glycol regenerator vent stream.
-
Bookshelf and Unified Agenda > Environmental Protection Agency > Office of Air Quality Planning and Standards > Locating and Estimating Air Toxics Emissions > ...
Process emissions from secondary-butyl alcohol dehydrogenation are noncondensible VOC (including MEK) and hydrogen from the reactor vents and distillation column condenser , each labeled with an emission point A in Figure 4-2.
-
States > California > State > Air Districts > Sacramento Metropolitan > Regulation IV - Prohibitions > [sac AQMD 455] Rule 455 - Pharmaceuticals Manufacturing
301.1 A person shall not use reactors, distillation columns, crystallizers, centrifuges emitting more than 15 pounds per day of VOC for each permit unit unless the vents are equipped with surface condensers or equivalent control devices.
Indicates content that may require registration and/or purchase.