Help with Teach Pendants specifications:
Type
Back to Top
|
|
| ||
| Control type | |||
| Your choices are... | |||
| Handwheel | Handwheel or dial control uses a manual pulse generator to other rotary input device to output a control signal. | ||
| Joystick | Joystick controllers use potentiometric, inductive or photoelectric sensing systems and/or switches to translate joystick motion into an output signal. | ||
| Multifunction Keypad | Multifunction keypads are standard size membrane or carbon pill keypads. | ||
| Pushbutton | Pushbutton switches are mechanical switches defined by the method used to activate the switch. The activation method is typically in the form of a plunger that is pushed down to open or close the switch. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
NEMA Enclosure Type
Back to Top
|
|
| ||
| NEMA Enclosure Type | |||
| Your choices are... | |||
| Type 1 | Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt. | ||
| Type 2 | Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment, to provide a degree of protection against falling dirt, and to provide a degree of protection against dripping and light splashing of liquids. | ||
| Type 3 | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust; and that will be undamaged by the external formation of ice on the enclosure. | ||
| Type 3R | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure. | ||
| Type 3S | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, and windblown dust; and in which the external mechanism(s) remain operable when ice laden. | ||
| Type 4 | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure. | ||
| Type 4X | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure. | ||
| Type 5 | Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against settling airborne dust, lint, fibers, and flyings; and to provide a degree of protection against dripping and light splashing of liquids. | ||
| Type 6 | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water and the entry of water during occasional temporary submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure. | ||
| Type 6P | Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against hose-directed water and the entry of water during prolonged submersion at a limited depth; and that will be undamaged by the external formation of ice on the enclosure. | ||
| Type 7 | Enclosures constructed for indoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, or D as defined in NFPA (National Fire Protection Agency) 70. | ||
| Type 8 | Enclosures constructed for either indoor or outdoor use in hazardous locations classified as Class I, Division 1, Groups A, B, C, and D as defined in NFPA (National Fire Protection Agency) 70. | ||
| Type 9 | Enclosures constructed for indoor use in hazardous locations classified as Class II, Division 1, Groups E, F, or G as defined in NFPA (National Fire Protection Agency) 70. | ||
| Type 10 | Enclosures constructed to meet the requirements of the Mine Safety and Health Administration, 30 CFR, Part 18. | ||
| Type 11 | Enclosures constructed for immersion of enclosed equipment in oil. Acid or fume resistant. | ||
| Type 12 | Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against dripping and light splashing of liquids. | ||
| Type 12K | Enclosures constructed (with knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against dripping and light splashing of liquids. | ||
| Type 13 | Enclosures constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against the spraying, splashing, and seepage of water, oil, and noncorrosive coolants. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Pendant Specs
Back to Top
|
|
| ||
| Number of Buttons / Keys: | Number of buttons on the pendant, usually they come in pairs: 1 pair = 2 buttons. | ||
| Search Logic: | User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria. | ||
| Number of Speeds: | |||
| Your choices are... | |||
| Single | The pendant has a single operating speed. | ||
| Two | The pendant has two different operating speeds. | ||
| Three | The pendant has three different operating speeds. | ||
| More than Three | The pendant has more than three operating speeds. | ||
| Search Logic: | Products with the selected attribute will be returned as matches. Leaving or selecting "No Preference" will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
| Features | |||
| Your choices are... | |||
| Emergency Stop | These devices are designed to initiate a complete shutdown of a system or process by pushing a single button or flipping a switch. | ||
| LCD/LED Display | LED and LCD displays are segmented or dot matrix displays allowing for numeric only, alphanumeric character or graphic representations. | ||
| Visual Indicators | Any type of visual indicator; could be a pilot light or led display. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Environment
Back to Top
|
|
| ||
| Operating Temperature: | Full required range of ambient operating temperature. | ||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||
| Vibration Rating: | This is the full required operating range related to vibration. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||
| Shock Rating: | This is the full required operating range related to shock. | ||
| Search Logic: | All matching products will have a value greater than or equal to the specified value. | ||