Interchangeable Plunger Syringes and Needles

15 Results
90197 -- CAL7643-01
from Hamilton Company

Hamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at the... [See More]

  • Configuration: Syringe Only
  • Volume: 0.0250
  • Injection Method: Manual
  • Pressure Rating: 2000
Adjustable Gel Loading Syringe -- 84611
from Hamilton Company

Gel electrophoresis is used in forensics, molecular biology, genetics, microbiology and biochemistry. The results can be analyzed quantitatively by visualizing the gel with UV light and a gel imaging device. The image is recorded with a computer operated camera, and the intensity of the band or spot... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Removable
  • Injection Method: Manual
  • Volume: 0.0100
Gastight 1000 Series Syringes -- 201200
from Hamilton Company

The 1000 series syringes are a mid volume Gastight syringe. This series of syringes is ideal for dispensing volumes from 100 μL up to 100 mL. A variety of different terminations and needle options are available in this series. [See More]

  • Configuration: Syringe Only
  • Volume: 1
  • Injection Method: Manual
  • Pressure Rating: 200
Gastight 1700 Series Syringes -- 201000
from Hamilton Company

The 1700 series syringes are the Gastight version of the original 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. A variety of different terminations and needle options are available in this series. [See More]

  • Configuration: Syringe Only
  • Volume: 0.0500
  • Injection Method: Manual
  • Pressure Rating: 1000
Gastight 1800 Series Syringes -- 7659-01
from Hamilton Company

The 1800 series syringes are the reinforced plunger version of the 1700 series syringes. Attached to the flange of the syringe is a blue Syringe Holder. The Syringe Holder provides a spot to hold the syringe that will not heat up the barrel causing dispense inaccuracies. Additionally it provides... [See More]

  • Configuration: Syringe Only
  • Volume: 0.0100
  • Injection Method: Manual
  • Pressure Rating: 1000
GC Autosampler Syringe -- 203043
from Hamilton Company

CTC Analytics ’ aim is to supply instruments to customers which make the operation of sample processing simple and transparent. In line with today ’s lab requirements for flexibility, capacity and precision, CTC has enhanced again the already proven reliability and productivity of their... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Fixed
  • Injection Method: Autosampler
  • Volume: 0.0250
GC Autosampler Syringe -- 203074
from Hamilton Company

C-Line syringes incorporate several unique design features that ensure superior performance. An improperly installed syringe can cause mis-injections or bent needles due to poor alignment. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Fixed
  • Injection Method: Autosampler
  • Volume: 0.0250
GC Autosampler Syringe -- 203082
from Hamilton Company

Modern GC Headspace analysis requires injecting over large temperature ranges (e.g. ITEX analysis). Traditional headspace syringes come with a rubber O-ring sealed plunger which has a limited sealing performance at high temperatures. The high dynamic HD-Type syringe employs a unique spring in the... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Fixed
  • Injection Method: Autosampler
  • Volume: 1
GC Autosampler Syringe -- 203206
from Hamilton Company

10 µL, Model 1701 SFN CTC SYR (6.6 mm), C-Line, Fixed NDL, Custom gauge, length, point style [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Fixed
  • Injection Method: Autosampler
  • Volume: 0.0100
Microliter 800 Series Syringes -- 7641-01
from Hamilton Company

The 800 series syringes are the reinforced plunger version of the original 700 series syringes. Attached to the flange of the syringe is a blue Syringe Holder. The Syringe Holder provides a spot to hold the syringe that will not heat up the barrel causing dispense inaccuracies. Additionally it... [See More]

  • Configuration: Syringe Only
  • Volume: 0.0050
  • Injection Method: Manual
  • Pressure Rating: 2000
Modified Microliter 7000 Series Syringes -- 80100
from Hamilton Company

The 7000 series syringes are considered modified Microliter syringes for their unique design. This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Removable
  • Injection Method: Manual
  • Volume: 0.0010
Multichannel Gel Loading Syringe -- 80081
from Hamilton Company

Multi-Channel Gel Loading Syringes are designed for multiplex DNA sequencing methodologies. You can rapidly transfer 8 or 12 samples to sequencing gels, MICROTITER ® plates or nylon membranes. It accurately dispenses from 0.2 to 10 µL of sample per syringe simultaneously. The 9 mm needle... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Fixed
  • Injection Method: Manual
  • Volume: 0.0100
PSD/8 Syringe -- 9882-30
from Hamilton Company

Long-life syringes were developed for extreme conditions that include harsh chemicals as well as abrasive particulate matter. The plunger tip is made from UHMWPE (Ultra High Molecular Weight Poly Ethylene) which is harder than PTFE to better resist scratching. In addition, the plunger rod is made... [See More]

  • Configuration: Syringe Only
  • Volume: 0.5001
  • Injection Method: Manual
  • Pressure Rating: 700
TLC Syringes -- 80050
from Hamilton Company

The needles on Thin Layer Chromatography (TLC) syringes are coated from the point for 3/4 ” with a PTFE-coating. The coating reduces the surface tension between the needle and the liquid making it ideal for reproducible sample spotting. The TLC syringe is available as a cemented needle (SNTLC)... [See More]

  • Configuration: Needle and Syringe
  • Needle Configuration: Fixed
  • Injection Method: Manual
  • Volume: 0.0100
Optimum® Syringe Barrels
from Nordson EFD

Optimum ® syringe barrels feature ZeroDraft ™ walls with consistent internal diameters that maintain an airtight seal with pistons to ensure accurate, consistent fluid deposits, eliminating the need to deal with messy blow-by, pressure variation, or contamination. Available in 3cc, 5cc,... [See More]

  • Configuration: Syringe Only
  • Volume: 3 to 55
  • Injection Method: Manual
  • Material: Plastic