-
Supplier: Anton Paar
Description: The Abbemat MW digital refractometer enables quick and fully automatic measurements of the refractive index at different measuring wavelengths, e. g. for dispersion and Abbe number determination.
- Measurement Scale: RI Detector
- Mounting: Portable
- Optical Wavelength Range: 436 to 656 nm
- RI Accuracy: 4.00E-5 ±
-
Supplier: Anton Paar
Description: The Abbemat 200 refractometers provide fast and accurate measurement of refractive index or concentration in all industry branches, from pharmaceuticals, flavors and chemicals to beverages and food.
- Brix Accuracy: 0.0500 ±%
- Brix Range: 0.0 to 100 %
- Measurement Scale: RI Detector, Brix Detector
- Monitoring: Sample
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-DRB 2 is a handheld digital refractometer used to determine the refractive index and dextran, fructose, glucose, lactose and maltose content (%) of liquid. This IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10
- Features: Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector, Other
- Monitoring: Sample
- Mounting: Handheld
-
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-DRS 2 is a handheld digital sodium chloride (NaCl) and chlorine (Cl) refractometer used to determine the salinity or salt content (‰), chlorine content (‰), specific gravity (SG) and refractive index (nD) of liquid. This waterproof IP65-rated digital
- Features: Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector, Other
- Monitoring: Sample
- Mounting: Handheld
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-DRB 1 is a handheld digital refractometer used to determine the sugar content / refractive index of liquid in the 0 ... 90 % Brix / 1.3330 ... 1.5177 nD measuring range. This waterproof IP65-rated digital refractometer features automatic temperature
- Brix Accuracy: 0.1000 ±%
- Brix Range: 0.0 to 90 %
- Features: Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector, Brix Detector
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-DRH 1 is a handheld digital refractometer used to determine the sugar content / water content / degrees Baumé (Bé°) / refractive index of honey in the 0 ... 90 % Brix / 38 ... 5% water / 33 ... 48 Bé° / 1.3330 ... 1.5177 nD measuring range. This waterproof IP65
- Brix Accuracy: 0.2000 ±%
- Brix Range: 0.0 to 90 %
- Features: Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector, Brix Detector, Other
-
Supplier: Maselli Measurements
Description: keypad and stainless steel enclosure assure trouble free operation even in the process area. Simply closing the cover, without pushing any buttons, the LR-02 Easy Start measures the refractive index of the sample, calculates its concentration, and presents the value on the backlit LCD
-
Supplier: Maselli Measurements
Description: Special Maselli software for diagnostics and remote configuration The microprocessor-based model LR-01 automatic laboratory refractometer is Maselli's newest analytical instrument for laboratory use. With the push of a button, the instrument measures the refractive index of
-
Supplier: Shimadzu Corporation
Description: Previous manual refractometers (Shimadzu KPR-2) offered an angle display only. The refractive index corresponding to the angle had to be looked up in a special table. With the KPR-30V, the measured angle is read by the PC, which automatically calculates the refractive
- Features: Application Software Included
- Measurement Scale: RI Detector
- Monitoring: Sample
- Optical Wavelength Range: 436 to 644 nm
-
Supplier: Anton Paar
Description: Reliability, precision and convenience: Abbemat 3X00 refractometers offer you an exceptional combination of technical expertise and user-friendly operation for your refractive index and concentration measurements. The premium technology and compactness of the Abbemat 3X00
- Brix Accuracy: 0.0500 ±%
- Brix Range: 0.0 to 100 %
- Measurement Scale: RI Detector, Brix Detector
- Monitoring: Sample
-
Supplier: Vaisala
Description: control and increase bath life. The concentration is determined by making an optical measurement of the solution’s Refractive Index nD and temperature. The PR-33-S is mounted directly in-line with a flare or pillar fitting. The PR-33-S has a compact, metal-free construction and it only
- Features: Alarms, Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector
- Monitoring: Continuous
- Mounting: Permanent or Fixtured
-
Supplier: Vaisala
Description: -line with a pillar or flare fitting. The compact design allows integration to a wet bench or to a cabinet, where the need for foot print area is very low. The dissolved solids concentration is determined by making an optical measurement of the solution’s Refractive Index. The
- Features: Alarms, Automatic Temperature Compensation, Measures Temperature
- Measurement Scale: RI Detector
- Monitoring: Continuous
- Mounting: Permanent or Fixtured
-
Supplier: Anton Paar
Description: Abbemat digital refractometers allow fast and non-destructive refractive index measurements. They are factory calibrated with official standards from the Physikalisch-Technis che Bundesanstalt (PTB, National Metrology Institute of Germany). Refractive index
- Brix Accuracy: 0.0100 ±%
- Brix Range: 0.0 to 100 %
- Measurement Scale: RI Detector, Brix Detector
- Monitoring: Sample
Find Suppliers by Category Top
More Information Top
-
The Role of Ion Pairs in the Second‐Order NLO Response of 4‐X‐1‐Methylpiridinium Salts
Dipole moments m were measured by using a WTW- DM01 dipole meter (dielectric constant) coupled with an RX-5000 ATAGO Digital Refractometer ( refractive index ) according to the Guggenheim method.[14] Elemental analyses were carried out at the Dipartimento di Chimica Inorganica, Metallorganica…
-
Production and characterization of low-calorie orange nectar containing stevioside
Viscosity was measured by ubbelohde viscometer (Fischer, USA) and Brix was determined by measurement of the refractive index with digital refractometer (DR201-95, Kruss, Germany) at 20 °C (Sánchez-Moreno et al. 2003).
-
Aqueous two phase partitioning of fish proteins: partitioning studies and ATPS evaluation
Determination of PEG concentration was performed by mea- suring refractive index using Digital refractometer (RX-500, ATAGO Co. ltd, Japan).
-
EFFECT OF COATINGS OVER THE QUALITY AND SHELF LIFE OF MANGO ( MANGIFERA INDICA L.) FRUIT
The total sugar was measured by measuring the refractive index using digital refractometer .
-
Standardised methodology for testing malolactic bacteria and wine yeast compatibility
The progress of fermentation was monitored by measurement of the refractive index ( digital refractometer , Atago) of clarified fermentation samples (1–2 mL).
-
Preparation, characterization, and performance of a novel hollow fiber nanofiltration membrane
The solvent concentration in coagulation bath was measured with time by refractive index using a digital refractometer (M/s, Cole-Parmer, Kolkata, India).
-
Developing fruit‐based nutritious snack bars
The pH was directly measured on the filtrate with a pHmeter (Schott Handylab; Schott, London, UK), following the AOAC method.12 The water soluble compounds were also quantified in the filtrate by refraction index using a digital refractometer Reichert AR 200 (Tokyo…
-
Modification of Transverse NMR Relaxation Times and Water Diffusion Coefficients of Kiwifruit Pericarp Tissue Subjected to Osmotic Dehydration
The soluble solids content (SSC) was determined at 20 °C by measuring the refractive index with a digital refractometer (PR1, Atago, Japan) calibrated with dis- tilled water.
-
Influence of choice of yeasts on volatile fermentation-derived compounds, colour and phenolics composition in Cabernet Sauvignon wine
Alcoholic fermentation (AF) was monitored daily by measurement of refractive index using a digital refractometer (PR-101 ATAGO, Japan).
-
Postharvest Quality and Shelf Life of Mango ( Mangifera indica L .) Fruit as Affected by Various Coatings
The total sugar was mea- sured by determining the refractive index using a digital refractometer .
Indicates content that may require registration and/or purchase.