Supplier: Automated Water & Effluent, Ltd.
Description: budget Redox electrode and has a low impedance glass bulb, single junction reference and a silver chloride element. The mounting cap on the budget pH Electrode model 9016-10B is Ryton with a small flange for mounting the Redox electrode into our RES style inline redox
- ORP Range: -2,000 to 2,000 millivolts
- Operating Temperature: 32 to 122 F
- Body Material: Epoxy or Polymer
- Mounting Options: In-Line (Insertion)
-
pH Electrodes - pH Electrode, Fermentation, 12 x 225 mm, Open junction, S8 connection -- GO-29045-16Supplier: Cole-Parmer
Description: samples which clog normal electrodes Cole-Parmer's fast-response fermentation pH electrodes are made of a proprietary new formulation of low-impedance glass replaces all other formulas
allows you to streamlined inventories and eliminate wasted time trying to select the - pH Range: 0 to 14 ph
- Operating Temperature: 266 F
-
Supplier: InspectorTools
Description: accessories can be added in the future. Wood Plaster Drywall block Ceramic tile Brick Roofing Most materials found in the building envelope for the which includes the meter, temperature and relative humidity probe, hand held electrode, hammer electrode, infrared surface
-
-
pH Electrodes - pH Electrode, Fermentation, 12 x 120 mm, Open junction, S8 connection -- GO-29045-18Supplier: Cole-Parmer
Description: samples which clog normal electrodes Cole-Parmer's fast-response fermentation pH electrodes are made of a proprietary new formulation of low-impedance glass replaces all other formulas
allows you to streamlined inventories and eliminate wasted time trying to select the - pH Range: 0 to 14 ph
- Operating Temperature: 266 F
-
pH Electrodes - pH Electrode, Fermentation, 12 x 120 mm, wick junction, S8 Connection -- GO-29045-02Supplier: Cole-Parmer
Description: strong oxidizers or reducing agent samples Cole-Parmer's fast-response fermentation pH electrodes are made of a proprietary new formulation of low-impedance glass replaces all other formulas
allows you to streamlined inventories and eliminate wasted time trying to select the - pH Range: 0 to 14 ph
- Operating Temperature: 266 F
-
pH Electrodes - pH Electrode, Fermentation, 12 x 225 mm, wick junction, S8 Connection -- GO-29045-00Supplier: Cole-Parmer
Description: oxidizers or reducing agent samples. Cole-Parmer's fast-response fermentation pH electrodes are made of a proprietary new formulation of low-impedance glass replaces all other formulas
allows you to streamlined inventories and eliminate wasted time trying to select the best - pH Range: 0 to 14 ph
- Operating Temperature: 266 F
-
Supplier: Sonel Test
Description: Multifunctional earthing and soil resistivity meter The Sonel MRU-200 earth resistance and soil resistivity meter for earth resistance and soil resistivity measurements with the use of various methods. The feature that definitely distinguishes this model from other meters of
- Display: Digital Meter
- Testing Method: Manual
- Features: Other
-
Supplier: InspectorTools
Description: pocket size non-destructive digital display moisture meter for measuring percentage moisture content in concrete and comparative readings in other floor screeds. The Concrete Encounter CMEXpert is a digital version of the Tramex Concrete Encounter CME4 hand-held electronic impedance
-
Supplier: Sonel Test
Description: Multifunctional earthing and soil resistivity meter The Sonel MRU-200-GPS earth resistance and soil resistivity meter is a versatile meter for earth resistance and soil resistivity measurements. The device allows the use of all known earth resistance measurement methods. This
- Display: Digital Meter
- Testing Method: Manual
- Features: Other
-
Supplier: Transcat, Inc.
Description: auxiliary electrodes, or with electrodes and clamp for measurements in the presence of multiple ground paths Ground resistance using double clamps when it is not possible to use auxiliary electrodes Impulse ground resistance without disconnecting measured grounding Soil
-
Supplier: Gilson Company, Inc.
Description: The nondestructive Concrete Moisture Encounter measures moisture content using impedance measurements from electrodes located on the base of the meter. The Model HM-668A offers instant and accurate results. The Encounter is user calibrated at the start of each use. A pointer on
-
Supplier: InspectorTools
Description: Standard Equipment Includes: Instrument 9V battery Leather carrying case Instructions Upgrade #1: EIFS Inspection Kit additionally includes: Professional Wood Meter Hand held electrode Heavy Duty 2 pin punch The detection, evaluation and accurate locating of excess moisture in
-
Supplier: InspectorTools
Description: being installed How does it work? In Moisture measuring mode it uses the principle of electrical impedance measurement to give accurate non-destructive moisture readings in concrete and gypsum floor screeds. From Electrodes with special spring mounted probes on the base of the
-
Supplier: OMEGA Engineering, Inc.
Description: The pHACT is a Fast Acting pH Sensor, with a built-in differential amplifier and 100 ohms ATC sensor that provides a compensated output compatible with any pH meter. It is an ideal solution for ground loop problems, since it has a built-in solution ground and low impedance output,
- pH Range: 0 to 14 ph
- pH Accuracy: 0.1 (+/- % FS)
- Response Time: 10 seconds
- Operating Temperature: 32 to 230 F
-
Supplier: ValueTronics International, Inc.
Description: constant of solid dielectric materials accurately, and complies with ASTM D150. The Agilent 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the
Find Suppliers by Category Top
Conduct Research Top
-
A Microfluidic System for Biological Particle Enrichment Using Contactless Dielectrophoresis
Report. 224 JALA June 2010. electric field, has shown great potential as a method for sample. concentration.5,6 Typically, sample concentration. through DEP involves the placement of an array of interdigitated. electrodes under a microfluidic channel through which. the sample fluid passes
More Information Top
-
Impedance measurement of individual skin surface electrodes
A small, portable electrode impedance meter capable of taking measurements from two skin surface electrodes simultaneously, but individually, at the same frequency, is presented.
-
Determination of the relationship between the pH and conductivity of gastric juice
Both these sets of samples were then measured using a four- electrode impedance meter (Multi-Frequency Tissue Impedance Meter, LB/1907, Medical Physics Department, Royal Hallamshire Hospital, UK).
-
Effects of circuit exercise and T ai C hi on body composition in middle‐aged and older women
Body composition was assessed using an eight-polar tactile- electrode impedance meter (InBody 720; Biospace, Seoul, Korea), which simultaneously recorded bodyweight, total body fat mass, total body muscle mass, lean body mass, bone mineral content and basal .
-
A microcomputer system for physiological data collection and analysis
Fig. 1.-a, Electromyograph. b, Interface. c, Preamplifier (30 X 25 mm). d, Electrode impedance meter .
-
A portable impedance meter for monitoring liquid compartments of the human body under space flight conditions
The tetrapolar (commutation of current and poten tial electrodes ) impedance meter implements the method .
-
Electrical properties of pig colonic mucosa measured during early post‐natal development.
A, d.c. generator; B, micro- electrode impedance meter ; C, micro-electrode; D, D', agar-KCl bridges; E, E', Ag/AgCl electrodes; F, F', high impedance pre-amplifiers; 0, dual beam oscilloscope; H, two pen recorder.
-
Effects of Reference Electrode Location on Monopolar-derived Multifocal Electroretinograms in Cynomolgus Monkeys
Impedances were <5 kW (Grass Electrode Impedance Meter Model F-EZM5, As- tro-Med, Inc., Grass Instrument Division, West .
-
On classifiability of wavelet features for EEG-based brain-computer interfaces
using the General Devices Prep-Check Plus ElM 107-25B Electrode Impedance Meter .
-
Slope walking causes short‐term changes in soleus H‐reflex excitability
Low impedance (<10 kO) was verified for all stimulating and recording electrodes using an electrode impedance meter (UFI MkIII Checktrode, Model 1089).
-
Optimization of Impedance Spectroscopy Techniques for Measuring Cutaneous Micropore Formation after Microneedle Treatment in an Elderly Population
The electrodes (measurement and reference) were connected to an impedance meter (EIM-105 Prep- Check Electrode Impedance Meter ; General Devices, Ridgefield, NJ) that applied a low-frequency alternating cur- rent modified with a 200 kΩ resistor in parallel (IET labs, Inc., Westbury …
Indicates content that may require registration and/or purchase.