Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-G28 is a portable, handheld gauss meter that detects electromagnetic fields (EMFs) and displays measurement results in milliGauss (mG) or microTesla (µT). This EMF radiation detector comes with an external 3-axis electromagnetic sensor (X, Y, Z direction).
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-MFM 3000 is a handheld electromagnetic radiation meter or gauss meter that detects both static (DC) permanent (rare earth) magnetic and dynamic (AC) electromagnetic fields (EMFs) and displays measurement results in gauss (G) or milli Tesla (mT). This
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-MFM 3000 is a handheld electromagnetic field meter or gauss meter that detects both static (DC) permanent (rare earth) magnetic and dynamic (AC) electromagnetic fields (EMFs) and displays measurement results in gauss (G) or milli Tesla (mT). This
- Magnetic Field Range: 0 to 30,000,000,000 microgauss
- Operating Temperature: 0 to 50 C
- Options & Features: Battery Powered
- Display Type: Digital
-
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: PCE-MFM 3000 is a handheld electromagnetic radiation detector or gauss meter that detects both static (DC) permanent magnet (rare earth) magnetic and dynamic (AC) electromagnetic fields (EMFs) and displays measurement results in gauss (G) or milli Tesla (mT). This
- Operating Temperature: 32 to 122 F
- Display Options: Digital
- Detector Style: Portable Detector
-
Supplier: AlphaLab, Inc.
Description: to 29.999 kilogauss (20000 to 29999 gauss) in 1 gauss steps. Therefore a change as small as 0.1 gauss could be measured, for example, in a 14,000 gauss field (typical of the strongest possible field from a permanent magnet). With an optional high-stability probe, it has
-
Supplier: AlphaLab, Inc.
Description: The meter has been optimized for easy use. It begins reading 1/2 second after it is turned on and updates four times a second. Stability is excellent, with noise level of only 0.1 gauss. Reproducibility at constant temperature is better than one part in 5000, and is generally only
-
Supplier: AlphaLab, Inc.
Description: certificate. Price is $585 (USD). (A simpler 1-axis meter is available for $285.) Manufactured and calibrated in USA by AlphaLab, Inc., the model VGM is usually shipped the same day ordered. (This meter is optimized to measure magnetized parts; its range of 799.99 gauss is not
Find Suppliers by Category Top
Featured Products Top
-
different languages. Up to 750 data records can be stored in the memory of the belt tension measuring device. The belt tension measuring device is delivered completely ready for use. The scope of delivery includes the handheld device, the standard sensor with gooseneck, a magnetic holder, batteries (read more)
Browse Force and Torque Instruments Datasheets for PCE Instruments / PCE Americas Inc. -
outstanding stability and low wear. The housing is made of coated steel. The motor can be combined with high resolution optical or magnetic encoders. As well as handheld devices, it is also suitable for many other applications such as in aerospace, robotics, medical technology, special machinery (read more)
Browse DC Motors Datasheets for FAULHABER MICROMO -
The air quality meter is specially designed for long-term monitoring of climatic conditions in, for example, offices, classrooms or lecture halls. The air quality meter has various sensors. Among other things, the air quality meter has a carbon dioxide sensor up to 40,000 ppm, a temperature (read more)
Browse Particle Analyzers Datasheets for PCE Instruments / PCE Americas Inc. -
massive mining components at its Salem facility to evaluate wear, prepare for refurbishment, and ensure accurate reassembly. The parts measured up to six meters in diameter, some curved, some recessed, and all difficult to handle. The work had to be done outdoors. There was no controlled (read more)
Browse Dimensional and Profile Scanners Datasheets for FARO CREAFORM -
More Than a Reagent Dispenser While traditional handheld pipettes or larger automated liquid dispensers greatly deteriorate in accuracy and precision below 2 µL volumes, the Mantis automated liquid dispenser excels at low-volume dispensing in a wide variety of scientific workflows (read more)
Browse Laboratory Dispensers Datasheets for Formulatrix, Inc.
More Information Top
-
Analysis and Measurements of Magnetic Field Exposures for Healthcare Workers in SelectedMR Environments
For low magnetic field strength calibration, a powerful 0.5 T permanent magnet was used in conjunction with a Hirst Mag- netic Instruments GM04 handheld portable Gauss meter using a zero flux chamber.
-
News
Lake Shore's model 410 hand-held gauss meter is designed for accurate magnetic Lake Shore Cryotronics, Inc.
-
QP Toolbox
Sypris Test and Measurement’s Magnetics Division releases the F.W. Bell 5100 series handheld gauss meter , which measures the density of magnetic fields.
-
Optimal Configuration for Electromagnets and Coils in Magnetic Actuators
A handheld Gauss - meter was used to measure the magnetic field experimentally.
-
Radiant Heating and Cooling Handbook > ELECTRIC RADIANT HEATING PANELS
A handheld or laboratory gauss meter is used to measure the magnetic field in milligauss (mG), which is one-thousandth of a gauss.
-
In vitro targeted magnetic delivery and tracking of superparamagnetic iron oxide particles labeled stem cells for articular cartilage defect repair
The magnetic flux of the magnet was measured with a hand-held Gauss meter .
-
Test before touch
A handheld gauss meter is placed against each cable, and the magnetic field strength is recorded as shown in Figure 13.
-
Measurement of residual magnetic field by superconducting magnets of the LHD
The residual magnetic field around the cryostat was measured with a hand-held gauss - meter when the glow discharging was not uniform in the plasma vacuum vessel.
-
The apparent dependence of the diffusion coefficient of N‐acetylaspartate upon magnetic field strength: evidence of an interaction with NMR methodology
A second set of samples exposed to 0.025 T, were placed about 1.5 m away from the 7 T magnet, and magnetic field strength at that site was measured using a hand-held Gauss /Tesla meter (F. W. Bell, Orlando…
-
Personnel Safety for Future Magnetic Fusion Power Plants
In a test field of 30 mT (300 Gauss ), hand-held beta-gamma survey meters showed susceptibilities to static and varying magnetic fields.
Indicates content that may require registration and/or purchase.