Products/Services for Inline Slurry Density Meters

Product News

More Information

Lock Indicates content that may require registration and/or purchase. Powered by IHS Goldfire

  • The Gunite and Associated Tanks Remediation Project Tank Waste Retrieval Performance and Lessons Learned, vol. 2 [of 2]
    The instruments included the Endress + Hauser Promass 63M Coriolis meter for measuring density , the Lasentec M600P for measuring particle size distribution, and a prototype ultrasonic monitor that was developed by Argonne National Laboratory for measuring suspended solids concentration. .... In addition, the power consumption of the recirculation pump was monitored to determine whether this parameter could be used as a tool for in- line slurry monitoring.
  • ISA ADV CNTRL UNLEA PLA PER MAN BEN - Advanced Control Unleashed - Plant Performance Management for Optimum Benefit
    If a den- sity measurement is sufficient, the coriolis meter offers the fastest and most accurate and reliable response. .... For simple water mixture and com- plex general mixtures, inline meters such as microwave and nuclear mag .... For coal, oil and mineral slurries , the prompt gamma neutron activation analyzer can deliver rapid, sample-free…
  • Semiconductor Manufacturing Handbook > WASTEWATER NEUTRALIZATION SYSTEMS
    Typically recirculation loops are employed with a metering valve, inline , for chemical delivery. .... Static lines are not acceptable because the slurry will separate, and the lines will plug, over time. .... normally quite insoluble, and due to the fact that lime is divalent, sludge densities are normally much…
  • Cementing Practices for Tubingless Completions
    A choke, usually a 1“ valve, is placed downstream of the denso- meter to create a 200 psi or greater pressure on the cement slurry . .... of this La to compress any entrained air that might cause an error in the density measurement. .... Cementers are instructed to mix the slurry to weight based on the in- line densometer.
  • Filtration and Leach Testing for PUREX Cladding Sludge and REDOX Cladding Sludge Actual Waste Sample Composites
    Permeate from filtration of the strontium carbonate slurry showed no solids present. .... The density of filter permeate was measured at 1.12 g/mL by the mass flow meter . .... For the SrCO3 flux measurements, the flow was slow enough to verify the flow with the in- line volumetric cylinder to measure the permeate flow.
  • Mining Water Management & Delivery |
    No seal water flush systems, strainers, dampeners, inline check valves, run-dry protection devices or other ancillary … pumps are self-priming to 9 m, can run dry safely and can meter accurately to ±1%. .... One common task is pumping paste backfill.  The goal for the high density paste formulations is .... Mining slurries often feature sub-micron solid contents in excess of 80% by weight, with specific gravity…
  • Scale-up of continuous chemical synthesis systems
    Fumaric acid is added using feed-forward control based on a second inline UV detector at a … cake is diluted to 15 wt% with ethyl acetate using feedback control from a density flow cell. .... This is typically done late in the formulation process, however, that would require metering SiO2 at 1 .... This is solved by metering the SiO2 in a slurry prior to drying.
  • EFRT M-12 Issue Resolution: Caustic Leach Rate Constants from PEP and Laboratory-Scale Tests
    …FT-0119; the measured value does not correct for line volume from the meter to the vessel .... Based on slurry level in vessel at ~57°C before direct steam injection: i) measured density corrected bubbler; ii) as-is bubbler (uncorrected); iii) vessel DrexelBrook (DB) (LT-0311); iv) laser (LT-0320). .... Time-averaged inline caustic addition flowrate (kg/min) 12.7 -1/+3 .
  • EFRT M-12 Issue Resolution: Caustic-Leach Rate Constants from PEP and Laboratory-Scale Tests
    …FT-0119; the measured value does not correct for line volume from the meter to the vessel .... Based on slurry level in vessel at ~57°C before direct steam injection: i) measured density corrected bubbler; ii) as-is bubbler (uncorrected); iii) vessel DrexelBrook (DB) (LT-0311); iv) laser (LT-0320). .... Time-averaged inline caustic addition flow rate (kg/min) 12.7 -1/+3 .
  • An Evaluation of a Dual Coriolis Meter System for In-Line Monitoring of Suspended Solids Concentrations in Radioactive Slurries
    An in- line instrument is one that is connected to the process, analyzes the slurry as it flows through or by the instrument, and provides the results within seconds. .... testing,1 the project sponsor selected the Endress + Hauser Promass® 63 Coriolis meter (for measuring density ) and a prototype ultrasonic monitor that was developed by Argonne National Laboratory (for measuring suspended solids concentration) as the best prospects for a demonstration with a…


Product Announcements
Weiss Technik North America, Inc.
ESPEC North America Inc | Qualmark Products and Services
Weiss Technik North America, Inc.
Cincinnati Sub-Zero Products
Guangdong Atmars Industry Co., Limited