Products/Services for Isfet PH Meter Ks723 Shindengen
-
pH Transmitters - (45 companies)...a pH transmitter is able to convert the pH of a solution into an electrical signal. A pH transmitter differs from a pH meter because it has a communication interface which can transmit data to a control system or computer. The device employs... -
pH Electrodes - (179 companies)...ions which exert a positive potential on the sensing electrode. This potential difference is measured by a pH meter and converted to a pH output. When probe is immersed in an alkaline environment, the H+ ions migrate outside of the probe, leaving... -
pH Instruments - (398 companies)...testing. Detecting changes in potable water sources. Food and beverage stability testing. pH Measurement Devices. pH measurements are typically conducted using a pH meter. This device uses a glass electrode connected to an electronic meter. pH meters... -
pH Controllers - (117 companies)...pH and ORP controllers monitor and can control the pH (acidity or alkalinity) and/or the ORP (oxidation reduction potential) of liquids involved in a testing or process application. pH controllers monitor potential of hydrogen (pH) levels... -
Flow Meters - (1709 companies)Flow meters (flowmeters) and flow sensors are devices used for measuring the flow rate or quantity of a moving fluid or gas. How to Select Flow Meters. Image Credit: Aalborg Instruments, Clark Solutions. Flow meters are devices for measuring... -
Ion Specific Electrode Meters - (93 companies)...similar to those used by pH instruments; in fact, pH electrodes are simply ion selective electrodes which specifically respond to H+ ions within a solution. Activity vs. Concentration. While ISE meters are considered to measure ion concentration...
-
S Meters - (14 companies)S meters (strength meters, signal-strength meters) measure the strength of signals in communication systems such as receivers and transmitters. Typically, a portion of the rectified intermediate frequency (IF) signal from a receiver 's detector...
-
Milliohm Meters - (73 companies)Milliohm meters are capable of measuring very small resistances. Devices that use a four-wire Kelvin probe system pass a test current through the probe so that the voltage is sensed by the center pin. This test method eliminates contact resistance...
-
Utility Meters - (123 companies)Utility meters are used to monitor the consumption of water, gas or electricity by businesses or residences. Utility meters are used to monitor the consumption of water, gas, or electricity by businesses or residences. They differ in terms...
-
Phase Meters - (72 companies)Phase meters (phase testers, phase rotation meters) check the phase sequence and phase orientation in three-phase electrical systems. They are used for energy measurements, and the monitor the quality of audio and video transmissions. Correct phase...
Product News
-
Myron L Company
Field-Tested pH and Dissolved Solids Meters Readings You Can Count On. No water supply is completely pure. Every industrial, commercial or natural source contains dissolved solids or salts. These impurities contribute to scale, corrosion, poor taste, and environmental pollution that endanger animal and plant life. Myron L Company has two proven ways to measure such impurities. Our DS Meters TM provide fast, accurate, on-the-spot measurement of total dissolved solids (TDS) or conductivity. pDS Meters TM test conductivity or TDS, plus pH... (read more)Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
Myron L Company
Original Portable Dissolved Solids and pH Meters plus pH. Readings from their highly stable circuitry help assure product quality, prevent equipment damage and verify in-line instrumentation in a wide range of applications, some of which are listed above. Unique Field-Tested Design. Our unique, durable, field-tested design has evolved over more than 40 years, making Myron L (R) instruments among the most reliable and popular of their kind in the world. They're lightweight and compact, yet Myron L (R)'s DS and pDS Meters are also tough... (read more)Browse Water Quality Testing Instruments Datasheets for Myron L Company -
Myron L Company
pH and Salinity Soil Testing Plant health can be greatly affected by pH (acidic or basic), salinity (soluble salts), and alkalinity, yet these factors are often ignored by growers. AGRI-METERS TM for Soil Analysis and Fertilizer and Irrigation Optimization. Optimum soil pH is essential for obtaining maximum efficiency from fertilizers and herbicides. Regular testing of conductivity ensures that fertilizer solutions will contain the optimum level of salinity for maximum plant health and growth. Irrigation water, if high... (read more)Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
Myron L Company
Industrial Conductivity, TDS, and pH Analysis TechPro II Conductivity, TDS, pH and Temperature Meters. FEATURES: * Waterproof & Buoyant. * Keypad Calibration. * 0-20,000 mS/ppm. * 0-14 pH. * Long Life Internal Electrodes. * Full 4 Digit Display. * Auto Temperature Compensation to 25 C/77 F. * User Friendly. Please note: TechPro TM AR1 and ARH1 models have been redesigned and replaced by TechPro II TM models TP1 and TPH1. The PH1 is also available now. Please visit our website for more information. (read more)Browse Conductivity and Resistivity Meters Datasheets for Myron L Company -
Myron L Company
Portable, Wireless pH & Temperature Pocket Tester Ensure product quality, reduce waste, and protect the environment. The UltrapenX2 TM PTBT2 is accurate, affordable, easy to use, and delivers reliable, repeatable results. Use your Bluetooth (R)-enabled mobile device with the Myron L (R) UltrapenX2 PTBTX2 TM app to measure, store and export water quality data (includes time, date, and location) for pH and Temperature!. The UltrapenX2 PTBT2 is designed with high performance features including proprietary sensor design; accuracy of +-.01 pH... (read more)Browse Water Quality Testing Instruments Datasheets for Myron L Company -
Myron L Company
One-Button, Electrometric pH & Temp. Pocket Tester Ensure product quality, reduce waste, and protect the environment. The ULTRAPEN PT2 is accurate, affordable, easy to use, and delivers reliable, repeatable results. ULTRAPEN PT2 is designed with high performance features including: proprietary sensor design; accuracy of +-.01 pH; option of 1-, 2-, or 3-point calibration; automatic temperature compensation; user-selectable LIVE and HOLD modes; rugged aircraft aluminum body; durable, epoxy encapsulated electronics; easy-to-use one-button control... (read more)Browse Water Quality Testing Instruments Datasheets for Myron L Company -
Hamilton Company
DURACAL pH Buffers The DURACAL pH buffer family offers the advantages of high stability, high resistance against contamination, easy handling, and long lifetime. Additionally, DURACAL buffers provide features that are common to Secondary Reference Solutions, namely low uncertainty, and a documented traceability to international standards. Can you trust your buffer solution?. GMP, GLP, ISO 9001, EN 45000, Calibration, Verification, Traceability, Certification from an accredited organization: Key words... (read more)Browse Inorganic Chemicals and Compounds Datasheets for Hamilton Company -
Hamilton Company
Polilyte HT pH Sensor Polilyte HT sensors have been designed to withstand demanding industrial processes in chemical, petrochemical, process water, and water treatment applications. The sensor has a maintenance-free design, as clogging is eliminated by the two single-pore junctions that enable direct contact between the Polisolve reference electrolyte and the sample, ensuring optimal measurement performance. Polilyte HT sensors show excellent measurement accuracy in highly alkaline solutions as well as in samples... (read more)Browse pH Electrodes Datasheets for Hamilton Company -
Hamilton Company
High-efficiency Separations At Any pH The Hamilton PRP-C18 is a new HPLC column designed to provide high-efficiency, reversed-phase separations over an extended column life in nearly any mobile phase or pH. The rigid stationary phase has excellent mechanical and thermal stability. ( > 100 C), does not shrink or swell, and is completely inert to most conditions commonly encountered in reversed-phase chromatography. The PRP-C18 is a durable and effective column for general purpose HPLC and especially well-suited for specialized... (read more)Browse HPLC Columns Datasheets for Hamilton Company -
Myron L Company
Standard Solutions and pH Buffers for Calibration in the International Critical Tables and traceable to the National Institute of Standards and Technology. The conductivity Standard Solutions and pH Buffers listed below are used for factory calibration. Regular use of these solutions is recommended to ensure specified instrument accuracy. Frequency of conductivity recalibration depends upon use, but once every month should be sufficient for an instrument used daily. pH models, depending upon use, should be recalibrated with pH 7 Buffer every 1-2 weeks... (read more)Browse Analytical and Chemical Standards Datasheets for Myron L Company
-
Collection of semen by manual stimulation and ejaculate characteristics of the black flying‐fox ( Pteropus alecto )
The ejaculate pH was measured by placing the undiluted semen directly on the pH sensor of a pH Meter ( ISFET KS723 Shindengen Electric MFG. Co. Ltd., Japan).
-
Diagnostics of atmospheric pressure microplasma with a liquid electrode
The pH values and conductivity of solutions are measured by a pH meter ( Shindengen , ISFET pH meter KS723 ) and a conductiv- ity meter (EC/TDS WATERPROOF FAMILY, HANNA, INSTRUMENTS), respectively.
-
The characterization of radio-frequency discharge using electrolyte solution as one electrode at atmospheric pressure
The pH values of solutions were measured by a pH meter ( Shindengen , ISFET pH meter KS723 ).
-
The trans Influence in the Modulation of Platinum Anticancer Agent Biology: The Effect of Nitrite Leaving Group on Aquation, Reactions with S‐Nucleophiles and ...
…to the next power of 2 in both f2 and f1 dimension. pH Measurements: For all {1 H,15 N} HSQC NMR experiments the pH of the solutions was measured using a Shindengen ISFET (semiconductor) pH meter (pH Boy- KS723 (SU-26F)).
-
Factors Affecting DNA–DNA Interstrand Cross‐Links in the Antiparallel 3′–3′ Sense: A Comparison with the 5′–5′ Directional Isomer
The pH of the solutions were measured by using a Shindengen ISFET (semiconductor) pH meter (pH Boy- KS723 ; SU-26F) and calibrated against buffers of pH 4.0 and 6.9.
-
Preparation and Formation Mechanism of ZrW 2 O 8 by Sol–Gel Process
The pH values of the zirconium solution, tungsten solution, and mixed sol were measured with an ISFET pH meter ( KS723 : Ag/ AgCl/KCl(sat.), Shindengen , Tokyo, Japan).
-
Diastereoisomerism of thiol complexes of arsenic acids and pseudoasymmetry of arsenic: a 1 H and 13 C NMR study
No consistent differences were found between readings made for buffers in D2O and those in water (Piccolo 2 HI 1290 meter with amplified pH electrode (Hanna Instruments, Portugal) and a ISFET KS723 solid-state meter ( Shindengen , Tokyo, Japan)) and no corrections for…
-
Complexes of diphenylarsinic acid and phenylarsonic acid with thiols: a 1 H and 13 C NMR study
No consistent differences were found between readings made for buffers in D2O and those in water [Piccolo 2 HI 1290 meter with amplified pH electrode (Hanna Instruments, Portugal) and an ISFET KS723 solid-state meter ( Shindengen , Tokyo, Japan)] and pHŁ values (where…
Indicates content that may require registration and/or purchase.