Supplier: Haida International Equipment Co., Ltd.
Description: 1. Purpose of Melt flow rate testing equipment: Melt flow rate testing equipment(also known as melt index meter) was measured under certain conditions thermoplastic melt flow rate of the special equipment. With the determination of melt flow rate MFR, measured melt volume rate
- Display & Special Features: Digital Readout, Graphic / Video Display
- Mounting / Loading Options: Laboratory / Batch
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR)
- Features: Polymers (Plastics, Elastomers)
-
Supplier: Haida International Equipment Co., Ltd.
Description: Coefficients of Friction ASTM D1424, ASTM D1922, ISO 1974: Elmendorf Tearing Strength Test About Plastic& Plastic Pipe Materials: ISO 180: Izod Impact Test ISO 9966: Ring Stiffness Test ISO 179: Charpy Impact Test ISO 4892: Weathering Aging Test ASTM D3163: Plastic
- Display & Special Features: Digital Readout
- Mounting / Loading Options: Laboratory / Batch
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR)
- Features: Polymers (Plastics, Elastomers)
-
Supplier: Haida International Equipment Co., Ltd.
Description: Melt Volume Rate (MVR) For Raw Material Test Standard: ISO 1133 – Determination of the melt mass-flow rate (MFR) and melt volume rate (MVR) of thermoplastics ASTM D 1238-Standard Test Method for Melt Flow Rates of thermoplastics by extrusion plastometer By Industry: Measurement of
- Display & Special Features: Computer Interface / Networkable, Digital Readout, Graphic / Video Display
- Mounting / Loading Options: Laboratory / Batch
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR)
- Features: Polymers (Plastics, Elastomers)
-
-
Supplier: Haida International Equipment Co., Ltd.
Description: deformation and draw rear time curve; 2)Do the second treatment for test data on the PC directly and test data can be leaded in the OFFICE soft to edit and typeset; 3)The test frame is made of invar and its deformation is zero; 4) The tank is designed small and its cooling rate
- Display & Special Features: Digital Readout, Graphic / Video Display
- Mounting / Loading Options: Laboratory / Batch
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR)
- Features: Polymers (Plastics, Elastomers)
-
Supplier: Tinius Olsen, Inc.
Description: identifiers they wish to use from a preloaded list or they can make their own identifier. They can also select which test results they wish to report. Test results are displayed automatically at the end of the test and can be saved or printed out to a printer connected to the
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR)
-
Supplier: ZwickRoell LP
Description: The compact Cflow extrusion plastometers were designed as stand-alone instruments for rapid inspection of the melt mass flow rates (MFR). They are mainly used for incoming goods inspections by plastics processing companies, where extrusion tests are performed sporadically.
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR), Processability / Plasticity (e.g., Plastometer, Extrusiometer)
- Features: Polymers (Plastics, Elastomers)
-
Supplier: ZwickRoell LP
Description: The Aflow is noted for being highly automated: whether simple cleaning and defined pre-compaction at the press of a button, or infinitely settable test loads, the Aflow extrusion plastometer adapts to your test tasks. The Aflow was developed specifically for laboratories with high
- Display & Special Features: Computer Interface / Networkable, Digital Readout
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR), Processability / Plasticity (e.g., Plastometer, Extrusiometer)
- Features: Polymers (Plastics, Elastomers)
-
Supplier: ZwickRoell LP
Description: The basic version of the Mflow extrusion plastometers can be used to determine melt mass flow rates (MFR).It features a modular design, and use of the piston displacement transducer expands the Mflow's capabilities to include determination of melt volume flow rate (MVR), as well as automatic,
- Display & Special Features: Computer Interface / Networkable, Digital Readout
- Properties Analyzed: Melt Flow Index (MFI, MFR, MVR), Processability / Plasticity (e.g., Plastometer, Extrusiometer)
- Features: Polymers (Plastics, Elastomers)
Find Suppliers by Category Top
More Information Top
-
Comparative effects of cobalt carboxylates on the thermo‐oxidative degradation of LDPE films
The MFI of the polymer was determined accord- ing to ASTM D 123815 at 1908C with 2.16 kg load using MFI testing equipment (International Equip- ments, Mumbai, India).
-
Geosynthetics in Civil and Environmental Engineering
Fig. 1 MFI equipment test .
-
Water Quality Monitoring in Membrane Filtration Systems
The specific clean water flux (CWF) was measured in the MFI -UF test equipment (see FIGURE2) using hyperfiltered water and calculat- ed according to Equation (10) corrected to 20°C (see TABLE1): .
-
Study on ester-amide exchange reactions between Nylon 1010 and Ethylene-vinyl acetate rubber with different metal derivatives
Melt flow index (MFI) was performed in a Dinateste plastometer (MPCA MFI , Ray-Ran Test Equipment Ltd., UK), according to GB/T 3682–2000, at 230 °C with a 2.16 kg load.
-
Study on ester–amide exchange reactions between Nylon 1010 and Ethylene‐vinyl acetate rubber
MFI was per- formed in a Dinateste plastometer (MPCA MFI , Ray-Ran Test Equipment Ltd., UK), according to GB/T 3628-2000, at 230 C .
-
Properties of poly(butylene terephthalate) chain‐extended by epoxycyclohexyl polyhedral oligomeric silsesquioxane
The melt flow index (MFI; ASTM 1238) was measured with a 5MPCA MFI testing instru- ment (Ray-Ran Test Equipment Ltd., Warwickshire, United Kingdom) with a 2.16-kg load at 2508C.
-
Building iPhone OS Accessories
Part of your MFi /WWi membership includes the ability to purchase test equipment that will help you to solve this and other kinds of errors.
-
MWH's Water Treatment: Principles and Design 3rd Edition Complete Document
…min−1 tI = time to collect first 500-mL sample, min tF = time to collect final 500-mL sample, min tT = duration of first two test intervals (15 min) The MFI (Schippers and Verdouw, 1980) uses identical test equipment but different procedures from…
-
Effect of styrene‐butadiene‐styrene addition on polystyrene/high‐density polyethylene blends
The MFI values were obtained according to ASTM D1238 using Ceast test equipment .
-
Achieving compatibility in blends of low‐density polyethylene/polyamide‐6 with addition of ethylene vinyl acetate
MFI values were obtained according to ASTM D 1238 using CEAST test equipment (Torino, Italy).
Indicates content that may require registration and/or purchase.