Supplier: SAE International
Description: This SAE Aerospace Standard (AS) covers the following basic types: Type I - Pitot pressure, straight and L-shaped, electrically heated. Type II - Pitot and static pressures, straight and L-shaped, electrically heated.
-
Supplier: SAE International
Description: This SAE Aerospace Standard (AS) establishes minimum ice and rain performance criteria for electrically-heated pitot and pitot-static probes intended for use on the following classes of fixed-wing aircraft and rotorcraft. The classes of fixed-wing aircraft are defined by
-
Supplier: KANOMAX USA, INC.
Description: Compatible with manometers, pressure gauges and transmitters
- Air Pressure Differential: Yes
- Instrument Style: Insertion Probe Type
- Mounting: Fixtured or Permanent
- Operating Temperature: Up to 212 F
-
-
Supplier: KANOMAX USA, INC.
Description: Compatible with manometers, pressure gauges and transmitters
- Air Pressure Differential: Yes
- Instrument Style: Insertion Probe Type
- Mounting: Fixtured or Permanent
- Operating Temperature: Up to 212 F
-
Supplier: Accuris
Description: (R) Minimum Performance Standard for Pitot and Pitot-Static Probes
-
Supplier: Accuris
Description: Ice and Rain Minimum Qualification Standards for Pitot and Pitot-static Probes
-
Supplier: Accuris
Description: ICE AND RAIN MINIMUM QUALIFICATION STANDARDS FOR PITOT AND PITOT-STATIC PROBES
-
Supplier: Eastern Instruments
Description: VAP3®/PA and VAP3®/SA Pitot probe can be inserted into the duct utilizing a pre-fabricated weld on insertion port. When multiple probes are needed within the duct, the total and static sensing ports can be manifolded together. NEGLIGIBLE PRESSURE
- Accuracy: 2 ±% Full Scale
- Air Pressure Differential: Yes
- Audible or Visual Alarm: Yes
- Instrument Style: Insertion Probe Type
-
Supplier: Eastern Instruments
Description: incorporated into flow-conditioning devices, such as the High Beta®, designed for short duct run applications with turbulent air flow or to obtain optimal accuracy. Each VAP3® Pitot has multiple total and static sensing ports, specifically located to provide a full traverse of
- Accuracy: 2 ±% Full Scale
- Air Pressure Differential: Yes
- Instrument Style: Insertion Probe Type
- Measures Temperature: Yes
-
Supplier: Eastern Instruments
Description: incorporated into flow-conditioning devices, such as the High Beta®, designed for short duct run applications with turbulent air flow or to obtain optimal accuracy. Each VAP3® Pitot has multiple total and static sensing ports, specifically located to provide a full traverse of
- Accuracy: 2 ±% Full Scale
- Air Pressure Differential: Yes
- Instrument Style: Insertion Probe Type
- Measures Temperature: Yes
-
Supplier: TSI Incorporated
Description: The DP-Calc™ Micromanometer 5825 allows you to easily make HVAC pressure measurements. This robust instruments can be used with pitot probes to measure duct velocity. The high performance DP-Calc 5825 can calculate flow and has data logging capabilities. Applications
- Device Category: Sensor
- Pressure Reading: Differential
-
Supplier: TSI Incorporated
Description: The DP-Calc™ Micromanometer 5815 allows you to easily make HVAC pressure measurements. This robust instruments can be used with pitot probes to measure duct velocity. The DP-Calc 5815 is a simple-to-operate, handheld digital micromanometer for fast, accurate differential and
- Device Category: Sensor
- Pressure Reading: Differential
-
Supplier: Cole-Parmer
Description: detachable and functions as a stand-alone meter! Combine it with optional probes for increased flexibility in multiple measurement applications.
What’s included: micromanometer, 18" (46 cm) L pitot probe, two static pressure probes, 16-ft- Operating Temperature: 14 to 140 F
-
Supplier: TSI Incorporated
Description: testing, adjusting and balancing Building and system commissioning Cleanroom testing Included Items Manometer with carrying case (4) AA size rechargeable NiMH batteries Multi-country AC adapter 18 in. (46 cm) Pitot probe
- Device Category: Sensor
- Pressure Reading: Differential
-
Supplier: TSI Incorporated
Description: Items Manometer with carrying case (4) AA size rechargeable NiMH batteries Multi-country AC adapter 18 in. (46 cm) Pitot probe (2) Static Pressure probes 16 ft (4.8 m) Neoprene tubing Downloading software USB interface cable
- Device Category: Sensor
- Pressure Reading: Differential
-
Supplier: Badger Meter
Description: and mixing or that require dampening hardware or software. The impact velocity sensing holes are located along the leading edge and the true static sensing holes are on the exterior probe side. The probe does not generate any vortices or vacuum effects that impinge on the
- Gas Volumetric Flow Rate: 0.6685 to 2674 SCFM
- Liquid Volumetric Flow Rate: 5 to 20000 GPM
- Mass Flow Rate Range: 0.0110 to 44.1 lbs/min
- End Fittings: Threaded
-
Supplier: Cessna Aircraft Company
Description: Transponder Antenna VHF/GPS Antenna (2)` XM Antenna NAV Antenna Emergency Locator Transmitter External Antenna Stormscope Antenna Pitot System — Heated Static System Handheld Microphone Alternate Static
-
Supplier: Cessna Aircraft Company
Description: Antennas: Marker Beacon Antenna Transponder Antenna VHF/GPS Antenna (2) NAV Antenna Emergency Locator Transmitter External Antenna Pitot System — Heated Static System Handheld Microphone Alternate Static
-
Supplier: Cessna Aircraft Company
Description: Antenna VHF/GPS Antenna (2) XM Antenna NAV Antenna Emergency Locator Transmitter External Antenna Pitot System — Heated Static System Handheld Microphone Alternate Static Source Detailed Specifications
Find Suppliers by Category Top
Featured Products Top
-
for precise air flow measurement and control of your process. The VAP3® is a Differential Pressure based probe that works well with almost any transmitter. Types of VAP3® Pitots VAP3® Pitots are designed for Superior (read more)
Browse Air Flow Sensors Datasheets for Eastern Instruments
More Information Top
-
Springer Handbook of Experimental Fluid Mechanics
Fig. 4.8 Percentage error in the measured pressure, i. e., 100Cps, due to the effect of tip (∆ptip) and stem (∆pstem) on pressure measurement by static tube (or Pitot static probe ) (After Pope and Harper [4.21] .
-
A combined experimental and numerical analysis of UAV Pitot-static system error at low Reynolds number
Abstract—This paper describes how the placement of a Pitot static probe on an airfoil affects the Pitot static system error which arises due to viscous effects extending from the leading edge of the airfoil and probe.
-
http://calhoun.nps.edu/public/bitstream/handle/10945/1059/03Mar_Tan.pdf?sequence=1
Pitot static probe .
-
http://www.nasa.gov/centers/dryden/pdf/88626main_H-2216.pdf
Static pressure position error calibrations for a compensated and an uncompensated XB-70 nose boom pitot static probe were obtained in flight.
-
Handbook of Measurement in Science and Engineering, 2 Volume Set
(a) A boundary layer style hot-wire probe for thermal anemometry (Picture from TSI Inc. catalog, probe catalog #1261A) (b) Pitot static probe for veloc- ity measurement.
-
Civil Avionics Systems
Air data pressure parameters are sensed by means of pitot static probes and static sensors as shown in Figure 8.1.
-
Introduction to Avionics Systems
However, many civil transport aircraft (e.g., Boeing 747) have side mounted (‘L’) type Pitot static probes .
-
Federal Register > Tuesday, September 5, 2006 > [71 FR 52300] Airworthiness Directives; Bombardier Model DHC-8-400 Series Airplanes
This proposed AD would require repetitive cleaning/inspecting of the drain hole of each pitot static probe and repetitive cleaning of the pitot lines in the pitot static system.
-
Advances in Power and Electrical Engineering
The flow profiles are examined using Pitot static probe at five measurement points within the range of inflow Reynolds number, Rein= 5.786E+04-1.775E+05.
-
Federal Register > Wednesday, June 20, 2001 > [66 FR 33016] Airworthiness Directives; Boeing Model 747-400 Series Airplanes
SUMMARY: This amendment adopts a new airworthiness directive (AD), applicable to certain Boeing Model 747-400 series airplanes, that requires an inspection to detect miswiring of diodes in the heating system of the pitot static probes , and corrective action, if necessary.
Indicates content that may require registration and/or purchase.