-
Supplier: Reznor
Description: Model RDH is the new rooftop, power-vented addition to the Reznor® line of Pre-Engineered Ventilation Air-Handlers (PREEVA™). Model RDH is available in 11 sizes from 75MBH to 400MBH. Each size is designed for a minimum 81% thermal efficiency and is available for use with either natural
- Heating Capacity: 22 kW
- AC Voltage Required: 115 to 575 volts
- Maximum Air Flow: 1,406 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
-
Supplier: Reznor
Description: Model SHH is the new 91% efficient separated-combustion addition to the Reznor® line of Pre-Engineered Air-Handlers. The 1st ever separated combustion system in the commercial/industrial heating industry was introduced on a Reznor heater in the 1960s, and that proven technology is
- Heating Capacity: 92.02 kW
- AC Voltage Required: 115 to 575 volts
- Maximum Air Flow: 66 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
-
Supplier: Reznor
Description: Model RDH is the new rooftop, power-vented addition to the Reznor® line of Pre-Engineered Ventilation Air-Handlers (PREEVA™). Model RDH is available in 11 sizes from 75MBH to 400MBH. Each size is designed for a minimum 81% thermal efficiency and is available for use with either natural
- Cooling Capacity: 339,000 BTU/hr
- Voltage: 230 VAC
- Frequency: 50 Hz, 60 Hz
- Type: Central
-
-
Supplier: Reznor
Description: Model SHH is the new 91% efficient separated-combustion addition to the Reznor® line of Pre-Engineered Air-Handlers. The 1st ever separated combustion system in the commercial/industrial heating industry was introduced on a Reznor heater in the 1960s, and that proven technology is
- Cooling Capacity: 395,999.99999999994 BTU/hr
- Voltage: 230 VAC
- Frequency: 60 Hz
- Type: Central
Find Suppliers by Category Top
More Information Top
-
Reaching for Peak Performance in Existing Homes -- A Cold Climate Study With Synergy Construction
• A propane furnace with on-demand water heater option appears to be at a slight cost advantage relative to a propane boiler with air handler option even though the boiler is able to use the existing hot water storage tank.
-
Analysis of the Energy Performance of the Chesapeake Bay Foundation's Philip Merrill Environmental Center
A preliminary list of data that should be recorded from the EMS includes thermostat set points, states of all systems related to natural ventilation (exhaust fans, window operators, and the Windows Open signage), CO2 sensor, air - handler stage, and propane flow.
-
Elk Valley Rancheria Energy Efficiency and Alternatives Analysis
The HVAC system is comprised of a combination of electric heat pump air units and four propane gas fired on the ground Air Handler Units.
-
Residential Fuel Cell Demonstration Handbook: National Rural Electric Cooperative Association Cooperative Research Network
This can be by substitution of a natural gas / propane furnace for the heat pump air handler or, alternately, by the replacement of the supplemental heaters with an hydronic coil connected to the converted, thermal recovery water heater.
-
Karuk Tribe Strategic Energy Plan and Energy Options Analysis
Combined Hydronic HVAC & DHW Combined Hydronic w/ air handler R-4.2 duct wrap Propane DHW EF 0.525 .
-
Shutdown plan for the 300 area fuel supply facilities
storage area. conference rooms, and one change room. roof-mounted air handlers . evaporative coils have been turned off. wall-mounted propane heaters.
-
Implementation of grounding, bonding, shielding and power system improvements in FAA systems: reliability assessments of the terminal Doppler weather radar (TD...
…detector exhaust hood; a common grounding plate for the waveguide, its unistrut support structure and the two antenna conduits; the E/G intake hood; the E/G load bank frame; the propane fuel line; and each … separately to the nearest air handler intake hoods.
-
Building America Industrialized Housing Partnership (BAIHP)
…right-sized heat pump, programmable thermostat with outdoor thermostat which prevents strip heat turn-on above freezing • Instantaneous propane water heater • Compact … Out of 100 Indoor Air Quality Features • Fresh … only when the air handler unit is on) •…
-
Railquip Inc
…equipment for railcar and locomotive workshops: battery-powered railcar movers ranging in capacity from 110 to 770 tonnes; gasoline-, propane gas-, and diesel-powered … power lift bags; compressed air stations; wheel presses and wheel lathes; mechanical wheel handlers ; mobile and stationary waste…
Indicates content that may require registration and/or purchase.