Products/Services for PT100 Kamstrup
-
RTD Temperature Probes - (447 companies)RTD (resistive thermal device) temperature probes are types of thermal resistors which measure temperature as a function of resistance. -
Resistive Temperature Devices (RTD) Elements - (205 companies)Resistive temperature device (RTD) elements are wire windings or other thin-film serpentines that exhibit changes in resistance with changes in temperature. They are usually made of metallic elements or alloys such as copper, nickel, or nickel-iron. -
Thermocouple Simulators and RTD Simulators - (39 companies)Thermocouple simulators and resistance temperature detector (RTD) simulators provide precise standard values of resistance or voltage for simulation and calibration. -
Metal Wire - (543 companies)Metal wires are flexible, typically cylindrical rods of metal. They are designed for carrying electricity and for bearing physical stresses and loads. -
RTD Temperature Transmitters - (399 companies)Resistance temperature detector (RTD) temperature transmitters convert RTD resistance measurements to current signals, eliminating the problems inherent in RTD signal transmission via lead resistance. -
Current Sources - (88 companies)Current sources provide reliable current for electrical component testing and for powering specialized components.
-
Signal Conditioners - (1038 companies)Signal conditioners provide amplification, filtering, converting, and other processes required to make sensor output suitable for reading by computer boards.
-
Thermistors - (331 companies)Thermistors are thermally-sensitive devices whose electrical resistance varies with temperature. Unlike RTDs and thermocouples, thermistors do not have standards associated with their resistance vs. temperature characteristics or curves.
-
Temperature Sensors - (624 companies)Temperature sensors are measurement devices that infer temperature by sensing some physical characteristic (i.e. resistance, emf or thermal radiation).
-
Current-to-Voltage Converters - (61 companies)Current-to-voltage converters scale and convert current signal input to the desired output voltage range.
Product News
-
Sichuan Odot Automation System Co., Ltd.
CT-3734: RTD Temperature Acquisition Module ? The module supports 4-channel RTD thermal resistance (PT100) temperature acquisition. ? The channels are isolated, and the isolation voltage is 1500V. ? The module could be connected to a 2-wire or 3-wire PT100 temperature sensor. ? The internal bus of the module and field input adopts magnetic isolation. ? The module carries with 4 analog input channel LED indicator. ? 15-bit ADC resolution (read more)Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
Sichuan Odot Automation System Co., Ltd.
CT-3713: RTD Temperature Acquisition Module The module supports 3-channel RTD thermal resistance (PT100) temperature acquisition The module could be connected to a 2-wire or 3-wire PT100 temperature sensor The internal bus of the module and field input adopts magnetic isolation The module carries with 3 analog input channel LED indicator 15-bit ADC resolution ???????????????? (read more)Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
Pyromation
Temperature Transmitters for All Applications Pyromation's recently updated line of temperature transmitters are designed for RTD/Pt100/Pt1000 & Thermocouple inputs & carry expanded approvals. HART (R) 7 Protocol, digital display & Bluetooth (R) options available. (read more)Browse Thermocouple Temperature Transmitters Datasheets for Pyromation -
Knick Interface LLC
Isolated Resistance Transmitter for High Voltage Pt100 Resistance Thermometers in high voltage environments need to be isolated in order to maintain proper function of temperature measurement. These thermometers can be insulated against high voltage. In practice, however, the available installation space is often too small. P44000 from Knick Interface brings a convenient and safe option for isolation in these scenarios. https://www.knick-international.com/en/products/interface-technology/proline/temperature-transmitters/proline-p-44000/. (read more)Browse RTD Temperature Transmitters Datasheets for Knick Interface LLC -
SAB BRÖCKSKES GmbH & Co. KG
High-Voltage Measurement Technology for E-Mobility mobile test drives and stationary test benches. In collaboration with CSM, SAB Br ockskes has developed a modular HV measurement system that covers the entire measurement chain, including HV thermocouples (type K), high-temperature variants, HV Pt100/Pt1000 resistance sensors, HV measurement cables, and certified HV modules. The selection of sensors is an important technical decision. Robust type K HV thermocouples are ideal for high-temperature and mechanically demanding locations... (read more) -
United Electric Controls Company
Case Study: Temperature Control in Gas Analyzers Solution. Some of the mechanical instrumentation required updating. Installing transmitters and analog PLC was cost prohibitive. The customer evaluated UE 's ONE Series Electronic Switch and decided to replace the mechanical switches with electronic ones. The ONE Series electronic switch specifically models (All-in-ONE) were selected for the following reasons: The ONE Series had 6 times better accuracy than a mechanical switch. In addition, the temperature model was fitted with a pt100 RTD... (read more)Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
United Electric Controls Company
Temperature Control in Gas Analyzer Shelters Some of the mechanical instrumentation required updating. Installing transmitters and analog PLC was cost prohibitive. The customer evaluated UE 's ONE Series Electronic Switch and decided to replace the mechanical switches with electronic ones. The ONE Series electronic switch specifically models (All-in-ONE) were selected for the following reasons: The ONE Series had 6 times better accuracy than a mechanical switch. In addition, the temperature model was fitted with a pt100 RTD, which... (read more)Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
Pyromation
Feel the Heat: RTDs Nail Temperature Every Time! of temperature range, the resistance of the lead wire is often compensated for with a three or four wire bridge configuration built into the measuring devices. By selecting the proper elements and protective sheathing, RTDs can operate in a temperature range of (-200 to 650) C [-328 to 1202] F. Pyromation manufactures RTDs for many industry applications. From single- or dual-element RTDs to PT100's to Sanitary CIP types, we have the right sensor for your job. If what you need is not available... (read more)Browse Resistive Temperature Devices (RTD) Elements Datasheets for Pyromation -
PCE Instruments / PCE Americas Inc.
Power Indicator PCE-ND30 in up to 10 groups with 8 measurement parameters. In addition to displaying the current measured values, the power display can also represent maximum and minimum values. Two built-up relays can be used for alarming at reduced or crossing borders. Optionally, the user still a 0/4 ... 20 mA analog output and two inputs for PT100 temperature sensors. Also, the power indicator can be equipped with an 8 GB memory and Ethernet interface. The network interface can be accessed on a web interface... (read more)Browse Digital Panel Meters Datasheets for PCE Instruments / PCE Americas Inc. -
Knick Interface LLC
Condition Monitoring of High-Voltage Motors attention, in an effort to find a solution for their network of plants. What they found was that after years of operation, insulation defects in their slot mounted temperature sensors installed in high-voltage motors were exposing downstream systems and personnel to dangerous voltage levels. This created the potential for a serious hazard that needed to be eliminated. The Solution: The P 44000 series was developed by Knick to accurately measure temperature from Pt100 RTDs in high-voltage... (read more)Browse RTD Temperature Transmitters Datasheets for Knick Interface LLC
-
The Impact of Overhead Heating System Height
on Greenhouse Air Temperature, Air Movement,
and Canopy Temperature
…rate was measured with an ultrasound flow sensor with pulse transmitter (Ultraflow 65-S, Kamstrup , Skanderborg, Denmark). .... The temperature sensors for supply and return temperature were RTD ( Pt100 ) (GW50, Senmatic, Odense, Denmark), and the…
-
Construction of a small scale laboratory for solar collectors
and solar cells in a developing country
Kamstrup 10EVL-MP110 energy and flow meter was adopted. .... PT100 (left) and LM35 (right) positioning .
-
Energy management through building automation
Cable 63 cable duct 64 calendars 30 calendar function 1016 Kamstrup 292 channel generator 382 cut of … psychological energy management 9, 20, 28, 363, 369, 374, 410, 420, 447, 983 PT100 655 pumping storage…
Indicates content that may require registration and/or purchase.