Products/Services for 12v Sump Pump Float Switches
-
Liquid Level Sensors - (734 companies)...sensors involve the opening or closing of a mechanical switch through either direct contact or magnetic operation from a device which floats on the surface of the measured liquid. Optical sensors detect the decrease or change in transmission...Device ClassificationLevel Measurement TypeField Adjustable Measurement Ranges -
Sump Pumps - (311 companies)Sump pumps are used in applications where excess water must be pumped away from a particular area. Sump pumps generally sit in a basin or sump that collects this excess water. Sump pumps are used in applications where excess water must be pumped... -
Pressure Switches - (759 companies)Pressure switches are actuated by a change in the pressure of a liquid or gas. They activate electromechanical or solid-state switches upon reaching a specific pressure level. Pressure switches are actuated by a change in the pressure of a liquid... -
Liquid Handling Pumps - (2272 companies)Industrial liquid handling pumps are classified in many different ways, and are distinguished by the media pumped and the fluid motive mechanism (dynamic or displacement). Pumps, in their simplest form, are machines for moving liquids. Industrial... -
Jet Pumps - (121 companies)...to the sewer line. A float level sensor and switch are used to turn on the pump. IEEE GlobalSpec's Pump Applications page provides an overview of pump types used for specific applications. References. Flotec - Jet Pump FAQs. Goulds Pumps - Jet Pumps... -
Industrial Valves - (3060 companies)...is operated either by the position of the valve or by the torque of the motor. A limit switch can be included to automatically stop the motor at fully open and fully closed. Solenoid operated valves use hydraulic fluid for automatic control of valve opening...
-
Control Panels - (731 companies)...and switches --used to control processes or machinery. They may also include displays in the form of light-emitting diode (LED) indicators, analog gauges, or numerical readouts. Control panels are manufactured according to their intended use...
-
Liquid Level Floats - (58 companies)...floats are spherical or cylindrical objects that are buoyant in water and other liquids. They are used for surface demarcation and level measurement. They may also be incorporated into switch assemblies to control liquid level. Liquid level floats...
-
Buoys and Floats - (70 companies)Buoys and floats are designed to float on the surface of a body of water, or are supported below the water 's surface to mark a location. They are used in marine navigation, boat mooring, nautical communications, and weather observation applications...
-
Product News
-
Arjay Engineering
Oil Sump Alarms in Wastewater Management the oil levels surpass the predetermined limit, facilitating immediate intervention. This ensures that industries can address contaminations promptly, reducing the risk of extensive environmental damage and ensuring regulatory compliance. Arjay Engineering 's Floating Oil Spill Alarm: 2852-HCF. The 2852-HCF Floating Oil Spill Alarm is a dependable tool designed to monitor sumps, tanks, and lagoons for oil spills. Using a hydrocarbon float sensor, it detects oil-on-water separation, ensuring... (read more)Browse Oil in Water Monitors Datasheets for Arjay Engineering -
Arjay Engineering
Protecting Water: The Oil Sump Alarm Role the oil levels surpass the predetermined limit, facilitating immediate intervention. This ensures that industries can address contaminations promptly, reducing the risk of extensive environmental damage and ensuring regulatory compliance. Arjay Engineering 's Floating Oil Spill Alarm: 2852-HCF. The 2852-HCF Floating Oil Spill Alarm is a dependable tool designed to monitor sumps, tanks, and lagoons for oil spills. Using a hydrocarbon float sensor, it detects oil-on-water separation, ensuring... (read more)Browse Liquid Leak Detectors Datasheets for Arjay Engineering -
QualiChem, Inc.
Clean machine tool sumps with EQO-KLEEN SMP Performance Benefits. Contains a proven industrial bioicide to help ensure a thoroughly clean machine. Operator friendly due to mild pH and pleasant citrus odor (contains d-limonene). Excellent corrosion protection helps prevent machine tools from rusting. Can be added directly to the old coolant and circulated for 24 hours prior to cleaning. Low foaming surfactants to prevent pump cavitations and foam-outs. Low reside formula allows for easy rinsing of machine tool surface before recharging... (read more)Browse Cleaning Agents and Surface Treatments Datasheets for QualiChem, Inc. -
Parker Sporlan Division
Float Drain Regulator The Float Drain Regulator is engineered to efficiently remove. liquid condensate from various components of a cooling system,. including evaporators during their defrost cycle, reheat returns,. condenser drains, and system traps. It features an oversized seat. orifice specifically designed for rapid liquid removal. (read more)Browse Control Valves Datasheets for Parker Sporlan Division -
Shenzhen Yunhongda Motor Co., LTD.
YHD-55PGM6340 Planetary Gear Motor, 12V DC and technical data to meet specific project requirements. High Torque and Efficiency: Offers a stall torque of 40-50 N.m and an output torque of 18-30 N.m at 12V DC. Low Noise: Noise levels are minimal at <=65db, ensuring quiet operation in sensitive environments. Wide Temperature Range: Operates effectively from -30 C to 80 C, making it suitable for various industrial and environmental conditions. CW/CCW Rotation: Bidirectional rotation capability for flexible use in different applications. Performance... (read more)Browse Gearmotors Datasheets for Shenzhen Yunhongda Motor Co., LTD. -
O'Keefe Controls Co.
Pneumatic Float Valves - Innovative Level Control Featuring rugged construction of durable stainless steel, O'Keefe Controls Co. Pneumatic Float Valves are long-lasting and suitable for use in a wide variety of liquids. Their non-electrical operation makes them especially appealing in industrial applications which carry an explosion hazard. They are available in either side- or top-mounting configurations for closed or vented vessels. Unique Design Allows Lower Cost of Operation. In the O 'Keefe Controls Co. Pneumatic Float Valve, the level... (read more)Browse Liquid Level Sensors Datasheets for O'Keefe Controls Co. -
Arjay Engineering
Floating Oil Spill Alarm for Sumps & Tanks Guard Against Spills: 2852-HCF Alarm Detects Oil Separation on Water. Protect your environment with the 2852-HCF Floating Oil Spill Alarm. This advanced sensor reliably monitors sumps and containments, detecting oil-on-water incidents quickly. Ideal for tanks, lagoons, and sumps, it alerts you instantly to spills, ensuring prompt response. Follow us on: Facebook. YouTube. LinkedIn. Twitter. Arjay Engineering. Engineering and manufacturing process and environmental controls since 1984. Our... (read more)Browse Oil in Water Monitors Datasheets for Arjay Engineering -
Midwest Motion Products, Inc.
Brushed 12V DC Gearmotor - MMP TM57-12V Series Description: Brushless 12V DC Gearmotor capable of producing up to 84 in-lbs continuous torque and 212 in-lbs peak torque with an output speed of 51 RPM. IP54 protected and under 2.5'' diameter and under 8.0'' total length and weight is 4.3 lbs. Download a Datasheet of this model here. Encoder-Compatible, Brake-Compatible or both rear shaft designs available. Samples readily available - can be built from Stock Materials, usually within just a day or two!. Short Production Lead-times - weeks... (read more)Browse Gearmotors Datasheets for Midwest Motion Products, Inc. -
Constar Motion Co., Ltd
12V Compact Flat BLDC Motor Precision medical and visual equipment often face space constraints, high-speed motion demands, and strict reliability requirements. Standard motors may be too bulky or unable to deliver the required performance, limiting device functionality. This 12V flat brushless DC motor offers a compact 32mm diameter and 11mm thickness, providing: High output power of 7.99W for demanding motion tasks. Fast rotational speed up to 14500 RPM for precise control. Customizable options including lead wire... (read more)Browse Brushless Motors Datasheets for Constar Motion Co., Ltd -
Constar Motion Co., Ltd
12V Micro Brushless Gimbal Motor Precision and compact design challenges are common in UAV gimbal systems, where space constraints and camera stabilization demand high performance. Engineers require reliable, high-speed motors to achieve smooth and responsive control. Key Features & Advantages: Compact design: 20mm diameter, 15mm thickness, ideal for small UAV gimbals without sacrificing performance. High speed: Up to 11,300 RPM for precise and stable camera stabilization. Flexible voltage options: Available in 12V and 5V... (read more)Browse DC Motors Datasheets for Constar Motion Co., Ltd
-
Little Giant SPBS-12 12 Volt DC Battery Back-Up System (506400) at PlumberSurplus.com
It will also function as an alarm system if the primary pump fails to empty the sump pit. .... • Check valve, T-connector and vertical mechanical float switch included for easy installation. .... • Battery box holds 12v deep cycle marine battery rated 105-140 amp-hours (battery not included) .
-
Manual combustion engine
…in the rule on the bottom spot of the gear in the oil sump , as, here, pressure .... In the driving apparatus, the fünfpolige plug, the contact for eight valves, two floats , are also the … eight become valves as well as an excited brushless electric motor for an oil pump is driven. .... Integrated gear driving apparatus for GM with an On/Off- and six VBS valves and four pressure switches . .... BATTERY ( 12V/36V ) .
-
Centrifugal Pumps
Leakage losses at the impeller inlet are reduced by a floating seal ring. .... The pump is mounted between flanges in the pipeline; no additional support is required. .... ometry or in the flow rate can cause the flow pattern to switch between differ- ent states. .... If the pump takes suction from an open sump , rotation-braking structures are also required to reduce .... 2 12v .
-
Centrifugal Pumps
Leakage losses at the impeller inlet are reduced by a floating seal ring. .... The pump is mounted between flanges in the pipeline; no additional support is required. .... ometry or in the flow rate can cause the flow pattern to switch between differ- ent states. .... If the pump takes suction from an open sump , rotation-braking structures are also required to reduce .... 2 12v .
Indicates content that may require registration and/or purchase.