Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Dupont Water Solutions
Description: AMBERJET™ UP6040 is a semi-conductor grade ion exchange resin mixed bed specifically designed for use in non regenerable final polishing units in the highest purity water treatment applications.
- Filtration Grade (Micron Rating): 580 to 700 µm
- Maximum Temperature: 140 F
- Filter Medium Material: Anion Exchange Resin, Cation Exchange Resin, Ion Exchange Resin, Mixed Resin
- Configuration: Bulk Filter Media
-
Supplier: Serfilco, Ltd.
Description: recover gold and other metals from plating operations easily and economically. Select the proper resin for gold recovery from acid or cyanide rinse water. Depth of resin column assures good solution contact for maximum metal recovery. Gold is recovered by incinerating the resin.
-
Supplier: Dupont Water Solutions
Description: AMBERSORB™ 560 Polymeric Adsorbent is an effective, new synthetic media adsorbent for treating 1,4-dioxane and other organic contaminants in groundwater and wastewater. It can also be used to remove various contaminants from vapor or atmospheric streams. AMBERSORB 560 is regenerable in situ using
- Type: Adsorbent
- Form: Bulk / Raw Material
- Features: Other
- Application: Remediation / Restoration
-
-
Supplier: Serfilco, Ltd.
Description: purple to golden brown to indicate resin exhaustion. Specifications OPTIONAL: FLOW CONTROL VALVE - For most effective exchange. Recommended to control flow through resin. RESIN CANISTER CHAMBER - For convenient refill of resin. Trap filters are 30 micron depth
-
Supplier: ASTM International
Description: 11.1 This test method covers the determination of the amount of water retained by ion-exchange resins and is intended for testing both new and used materials. 18.1 This test method covers the determination of the backwashed and settled density of ion-exchange
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 500 g, anion exchange resin, chloride form, 4% crosslinkage, 200-400 dry mesh size, 45-75 µm wet bead size, ~1,400 MW limit  AG, AG-MP, and Bio-Rex 5 Resins AG (analytical grade) resins — AG resins are extensively purified to remove both organic and inorganic
- Filter Medium Material: Anion Exchange Resin
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 500 g, analytical grade anion exchange resin, chloride form, 4% crosslinkage, 50-100 dry mesh size, 180-425 µm wet bead size, ~1,400 MW limit  AG, AG-MP, and Bio-Rex 5 Resins AG (analytical grade) resins — AG resins are extensively purified to remove both
- Filter Medium Material: Anion Exchange Resin
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 500 g, analytical grade anion exchange resin, chloride form, 8% crosslinkage, 200-400 dry mesh size, 45-106 µm wet bead size, ~1,000 MW limit  AG, AG-MP, and Bio-Rex 5 Resins AG (analytical grade) resins — AG resins are extensively purified to remove both
- Filter Medium Material: Anion Exchange Resin
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 100 g, biotechnology grade anion exchange resin, hydroxide form, 2% crosslinkage, 200-400 dry mesh size, 75-180 µm wet bead size, ~2,700 MW limit  AG, AG-MP, and Bio-Rex 5 Resins AG (analytical grade) resins — AG resins are extensively purified to remove both
- Filter Medium Material: Anion Exchange Resin
-
Description: Portable Exchange Deionization resins reduce both positively and negatively charged ions for a consistent flow of high-quality water. These cation and anion exchange resins have a specific capacity to reduce a known amount of ions and need to be regenerated
-
Supplier: ASTM International
Description: 1.1 This practice covers the determination of the performance of oxygen removal ion exchange resin cartridges in the regenerated form when used for removing dissolved oxygen from water. The test can be used to determine the initial capacity of unused cartridges or the remaining
-
Supplier: Kontek Ecology Systems Inc.
Description: system is supplied with, a magnetic-coupled seal-less pump, pre-filter, up to three parallel piped resin columns, flow meters, and all valves required for regeneration of resins.
-
Supplier: Kontek Ecology Systems Inc.
Description: adjusted. Regeneration chemical levels are also monitored and controlled ensuring that each regeneration cycle is completed with optimal efficiency and regeneration waste is minimized. ReKon ion exchange systems are ideal for metal recovery, raw water purification,
-
Supplier: Cleaver-Brooks
Description: Dealkalization reduces the need for neutralizing chemicals by as much as 90% and cuts fuel cost by minimizing blowdown. The model CDAS is designed for larger industrial boiler-feed applications. It features twin tanks, alternating or parallel systems including carbon steel resin tanks, strong
- Continuous Flow Rate: 10 to 300 GPM
- Removal Application: Dealkalization
- Market: Industrial
-
Supplier: Watts
Description: Features & Benefits • Regeneration by time clock or meter • Automatic brine refill by timer or controller • Models for capacities to 1,200,000 grains • Fleck control valves • Steel tanks rated for 100 psi • Exterior tanks primed for protection • Face piping is galvanized • Electronic controls
- Market: Food / Medical / Sanitary
- Removal Application: Water Softening
-
Supplier: Watts
Description: softener, passing through the ion-exchange media where the minerals are removed by attaching to the resin media. The softened water then flows out to the fixtures. As the minerals build up on the media, the softening ability of the media gradually reduces until the softener
- Continuous Flow Rate: 10 GPM
- Market: Residential
- Removal Application: Water Softening
-
Supplier: Watts
Description: is being regenerated • Carbon pre-treatment dramatically extends resin life to reduce costs • Vortech® tanks, used for superior performance • Metered valve for greater efficiency and reduced water consumption • Refreshing shower water without hardness • Softer, brighter laundry • Reduced soap
- Market: Residential
- Removal Application: Water Softening
-
Supplier: Watts
Description: The controller compares the exhaustion rate against the water volume used and, at each regeneration cycle, recalculates the water hardness value in the programming. Combining a meter with resin exhaustion sensor technology, ProSense series water softeners solve the efficiency issues
- Market: Residential
- Removal Application: Water Softening
-
Supplier: Cleaver-Brooks
Description: mounted and pre-piped, pre-wired systems Optional ASME code stamped tanks Models FSE and SSE Available in single-, twin- or triplex tank designs and include resin tank(s), brine tank, resin, piping, multi-position top-mounted pison valves, flow meters and electronic demand controller.
- Continuous Flow Rate: 2 to 450 GPM
- Market: Industrial
- Removal Application: Water Softening
-
Supplier: Eco-Tec, Inc.
Description: delivers up to two times higher throughput rates than other softeners thanks to its: short bed height and small resin volume, low resin exchange loading, fine mesh resin, compressed resin beds, and counter-current regeneration.
-
Supplier: Kontek Ecology Systems Inc.
Description: wastewater discharge polishing, or precious metal recovery DeCat Series for Selective Ion Exchange Selective ion exchange uses proprietary selective resins to remove specific ions from wastewater to reduce contamination levels or recover desired heavy
-
Supplier: Mar Cor Purification
Description: Service deionization is a portable DI and carbon exchange service that allows customers to produce high purity water in an economical manner. A typical SDI system includes a carbon tank and ion exchange resin tanks which are designed and configured to meet your
- Features: Canada Only, North America, Other, United States Only
- Industry Served: Chemicals, Cosmetics, Foods / Beverages, Pharmaceuticals, Research and Development, Semiconductor Manufacturing
- Operation / Mounting: Clean in Place, Floor / Field, Laboratory / Bench, Skidded
- Services: Complete Machine / Turnkey System, Component / Sub-system Upgrades, Design Assistance, Inspection / Optimization, Installation / B.O.T. / Commissioning, Preventative Maintenance Plans, Repair / Overhaul Services, Training / Consulting
-
Supplier: Watts Premier
Description: Regular use with regular water softener salt promotes efficient performance. Compatibility: Water Softeners Features: Substances such as organics, silt, sand, oil, grease, iron and metal particles affect the performance of ion exchange systems. Proper care and cleaning of resin
-
Supplier: Eco-Tec, Inc.
Description: and continuously operates to remove dissolved aluminum from the tank. It does this using a simple process which involves passing the anodizing solution through a resin bed where the sulphuric acid and dissolved aluminum are separated. Periodically the resin is automatically
- Maximum Liquid Flow: 0.4843154286666667 to 7.264731429999999 GPM
- Application: Liquid
Find Suppliers by Category Top
Featured Products Top
-
: Charged contaminant capture via ion exchange Hydrogen bonding: Specific interaction with oxygen-containing groups (read more)
Browse Filter Elements Datasheets for Harbory Filtration -
hydrogen product lineup is its line of FORBLUE S-SERIES fluorinated ion exchange membranes specifically designed for polymer electrolyte membrane (PEM) water electrolysis. These membranes are a key component in the production of green hydrogen, enabling superior voltage performance and stable, long (read more)
Browse Microporous Membranes Datasheets for AGC Chemicals Americas, Inc.
Conduct Research Top
-
DOWEX TM MONOSPHERE TM Ion Exchange Resins (.pdf)
) along with procedure modifications for regenerating and re-mixing resin has enabled the Millstone secondary cycle chemistry group to reliably maintain a Chemistry Performance Index (CPI) value of 1.00 and reduce blowdown by 75%.
-
ACID SEPARATION FOR IMPURITY CONTROL AND ACID RECYCLE USING SHORT BED ION EXCHANGE
Acid separation using short bed ion exchange is a now well established technology in copper. refinery tankhouses. Refinery bleed streams from liberator cells are treated by short bed systems. to produce an acid-free byproduct stream that contains the bleed metals and valuable nickel salts. Removing
More Information Top
-
Water treatment
For regeneration, carbon dioxide is dissolved from the CO2 supply container (8) in the pressurized reaction container in water to carbonic acid, that is then flowed the mixing bed filters in the Aufstrom and the ion exchange resins regenerate .
-
Ion exchange technology in the remediation of uranium contaminated groundwater at Fernald
Ion Exchange Resin Regeneration Process .
-
MCFC PRODUCT DEVELOPMENT TEST
Ion Exchange Resin Regeneration : Develop an economical method of .
-
Sulfuric Acid
Sulfuric acid is used in the treatment of water and waste for pH control, ion exchange resin regeneration , precipitation of specific ions, etc.
-
LITERATURE REVIEW ON IMPACT OF GLYCOLATE ON THE 2H EVAPORATOR AND THE EFFLUENT TREATMENT FACILITY
2.2.7 2nd Mercury Removal .........................................................................................................................20 2.2.8 Ion Exchange .....................................................................................................................................20 2.2.9 Ion Exchange Resin Regeneration .....................................................................................................20 2.2.10 Evaporation......................................................................................................................................21 .
-
Study on Fenton Oxidation-Coagulation Process for the Treatment of Regeneration Wastewater from Ion Exchange Resin
Experimental results show that coagulation-sedimentation process method on ion exchange resin regenerating wastewater is efficiency.
-
http://www-pub.iaea.org/MTCD/publications/PDF/te_1492_web.pdf
Ion exchange resin regenerations .
-
Treatment of Cooling Water
Principle: Passage of the water on strong cationic ion exchange resins regenerated in the form of sodium.
-
Investigation of an acid spill caused by the failure of an air‐operated diaphragm pump
Abstract A spill of concentrated hydrochloric acid caused considerable damage at an ion exchange resin regeneration plant.
-
TREATABILITY TEST REPORT FOR THE REMOVAL OF CHROMIUM FROM GROUNDWATER AT 100-D AREA USING ELECTROCOAGULATION
flow rates will increase the cost and frequency of ion exchange resin regeneration ; therefore, alternative technologies are being considered for treatment at high flow rates.