Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Description: At Frick® by Johnson Controls, we offer 13 models of our LaZerWeld industrial heat exchangers, the world’s largest selection. Ranging in capacity from 115 to 4000 tons, these high quality industrial heat exchangers are specifically designed for use with ammonia,
- Applications: Refrigeration (Evaporator / Condenser)
-
Supplier: Alfa Laval Inc.
Description: The AlfaNova is the first plate heat exchanger in the world to be made completely of stainless steel – made possible by the unique active diffusion bonding technology patented by Alfa Laval. AlfaNova plate heat exchangers are made of 100% stainless steel, with the
- ASME Certified: Yes
- Applications: HVAC
- Connection Type: Flange, Solder, Tubular / Tube Fitting, Other
- Liquid Flow Rate: 881 GPM
-
Supplier: Alfa Laval Inc.
Description: bar at 150° C and maximum UL approval of 1595 psi at 302° F. The Alfanova X-treme pressure line is suitable to cover heat recovery duties, gas cooling, condensing, sub-cooling and suction gas heating. Applications Ammonia as refrigerant - Desuper heater, high pressure
- Applications: HVAC, Refrigeration (Evaporator / Condenser)
- Liquid Flow Rate: 61.6 GPM
- Maximum Working Pressure: 0.0 to 1668 psi
- Primary Exchanger Material: Stainless Steel
-
-
Supplier: Alfa Laval Inc.
Description: and TK20. The refrigerant flows in laser-welded, sealed plate channels, and the brine in gasketed channels. The flexible modular design copes with fatigue stresses and ice formation. The semi-welded heat exchanger handles most refrigerants on the welded side and is particularly
- Type: Plate
-
Supplier: Alfa Laval Inc.
Description: glycol solution as cooling medium Suitability for all LPG media, including ammonia Leakage protection – gas cannot enter the seawater loop Same low weight and high efficiency as copper-brazed heat exchangers Superior temperature range between -196°C and +550°C Weight: 400 kg
- Applications: Marine / Shipboard
- Primary Exchanger Material: Stainless Steel
- Temperature Range: -321 to 1022 F
- Type: Plate
-
Supplier: R. S. Hughes Company, Inc.
Description: is the proper adhesive material. This self-adhesive pipe marker uses permanent acrylic for the adhesive. Designed to mark the following type of pipe: ammonia, and has the following text printed: HEAT EXCHANGER.
- Type: Adhesive Label
-
Supplier: ASTM International
Description: This specification covers welded tube of specific copper and various copper alloys of a limited range of diameters, for use in surface condensers, evaporators, heat exchangers, and general engineering applications. The product shall be manufactured by forming the material into a
-
Supplier: ASTM International
Description: This specification establishes the requirements for forge-welded copper and copper alloy with integral fins for use in surface condenser, evaporator, and heat exchanger. The product shall be welded tube of one of the following Copper or Copper Alloy UNS Nos.: C12000, C12200, C19200,
-
Supplier: ASTM International
Description: This specification establishes the requirements for condenser, evaporator, and heat exchanger U-bends that are manufactured from seamless copper and copper alloy tube. The material of manufacture shall be of such quality and purity that the finished product shall have the properties
-
Supplier: Emerson Automation Solutions – Rosemount
Description: expect from a fixed gas detection solution. Sensors can be easily exchanged, with NE-MOS Solid State, Electrochemical, Infrared and Catalytic Bead sensor technologies available. The Millennium II transmitter automatically recognizes any connected pre-calibrated sensor and
- Display: Digital
- Electrical Outputs: Analog Current, Switch
- Features: Audible or Visual Alarms, Controller, Data Logger, Hazardous Environments
- General Gas Types: Toxic Gas, Combustible Gas
-
Supplier: Emerson Automation Solutions – Rosemount
Description: cover more area with a single transmitter - Mix & Match, Plug & Play! No other platform can offer this kind of versatility and performance. Sensors can be easily exchanged, with NE-MOS Solid State, Electrochemical, Infrared and Catalytic Bead sensor technologies
- Display: Digital
- Electrical Outputs: Analog Current, Switch
- Features: Audible or Visual Alarms, Controller, Data Logger, Hazardous Environments
- General Gas Types: Toxic Gas, Combustible Gas
-
Supplier: Branch Environmental Solutions
Description: increased by adding a Air-to-Air Heat Exchanger. The Air-to-Air Heat Exchanger is similar to the one used on a Direct Thermal. Catalytic units operate at low temperature which allows the use of a less expensive type of heat exchanger. All performance levels
- Oxidizer Type: Catalytic
- Required Airflow: 25004 SCFM
-
Supplier: ASTM International
Description: This specification establishes the requirements for seamless tube and ferrule stock of copper and various copper alloys of a specified range of diameters, for use in surface condensers, evaporators, and heat exchangers. The specified coppers and copper alloys are UNS No. C10100,
-
Supplier: Branch Environmental Solutions
Description: psig (1 – 2 Bar g) for example. Most steam stripping systems are built in accordance with ASME Code Section VIII Division 1 although other standards can be provided including an EU stamp. Where complete packages are required, Branch can provide all the necessary heat exchangers,
Find Suppliers by Category Top
Featured Products Top
-
The falling film chiller is engineered for demanding dairy process cooling applications where temperature stability and hygiene are critical. Designed as a skid-mounted package, the system integrates pillow plate heat exchangers and operates with ammonia (R717) as a natural refrigerant (read more)
Browse Heat Exchangers Datasheets for Hexnovas Heat Exchanger Technology Co., Ltd -
(evaporation and condensation) • Reduced footprint compared to shell-and-tube heat exchangers Typical Applications: • Ammonia (NH3) refrigeration systems • CO2 (R744) refrigeration and heat recovery • Industrial refrigeration and cold storage (read more)
Browse Heat Exchangers Datasheets for Hexnovas Heat Exchanger Technology Co., Ltd -
are required, Branch can provide all the necessary heat exchangers, stripper, pumps, controls and other components for a complete operating system. Principle of Operation Steam stripping relies on the higher vapor pressure of organics compared to water. The same types of (read more)
Browse Air Strippers Datasheets for Branch Environmental Solutions -
Air-to-Air Heat Exchangers Air-to-Air Heat Exchangers operate by taking the outlet hot gas and passing this through a heat exchanger with the cold inlet air on the other side of the tubes in the heat exchanger (read more)
Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
Dioxide and water vapor. The energy efficiency of the Catalytic unit can be increased by adding a Air-to-Air Heat Exchanger. The Air-to-Air Heat Exchanger is similar to the one used on a Direct Thermal. Catalytic units operate at low temperature which allows the use of a less expensive (read more)
Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
is converted to Carbon Dioxide and water vapor. The energy efficiency of the Catalytic unit can be increased by adding a Air-to-Air Heat Exchanger. The Air-to-Air Heat Exchanger is similar to the one used on a Direct Thermal. Catalytic units operate at low temperature which allows (read more)
Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
costly operating expense, it is possible to install an Air-to-Air Heat Exchanger. This will take the hot exhaust gas and preheat the incoming cold gas. By recovering part of the energy, operating cost can be controlled. Energy Recovery The process air stream, at a (read more)
Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
are required, Branch can provide all the necessary heat exchangers, stripper, pumps, controls and other components for a complete operating system. Branch Environmental supplies custom built pollution control equipment for industry. Our air (read more)
Browse Air Strippers Datasheets for Branch Environmental Solutions -
. To avoid costly operating expense, it is possible to install an Air-to-Air Heat Exchanger. This will take the hot exhaust gas and preheat the incoming cold gas. By recovering part of the energy, operating cost can be controlled. Energy Recovery The process air stream, at (read more)
Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Solutions -
packages are required, Branch can provide all the necessary heat exchangers, stripper, pumps, controls and other components for a complete operating system. Principle of Operation Steam stripping relies on the higher vapor pressure of organics compared to water. The same types (read more)
Browse Air Strippers Datasheets for Branch Environmental Solutions
Conduct Research Top
-
PROTECT YOUR INVESTMENT: Five factors to consider before making the switch to aftermarket oil
with low carryover potential: Lubricants designed to keep oil carryover low. are important to keep the compressor oils in the. compressors, not spread all over the system where. they can foul heat exchangers and require oil draining. Some aftermarket oils are blends of different. chemistry
More Information Top
-
Advances in Power and Electrical Engineering
Based on the operating characteristics of ammonia refrigeration system, the ammonia heat exchanger was designed to be installed in series on the ammonia main pipe, which can ensure the system operate efficiently and reliably.
-
Ocean thermal energy conversion—materials issues
Large size seawater- ammonia heat exchangers are neces- sary, both for the evaporator and the condenser, in order to transfer sufficient energy across the small temperature dif- .
-
A comparison of procedures for estimating the impact of nondensable gases on steam condensation taking into account the interaction of power engineering proces...
1) Reac- tor tubing of the PSS, (2) ammonia heat exchanger , and (3) heat exchanger conveying heat from ammonia to the environment.
-
Control Stability Analysis Applied to Columbus ATCS
The CHX "right" part consists of the water- ammonia heat exchangers (MT and LT), the HX bypass, WMV3&4, WTSB 3&4 and the CHX (see Figure 14).
-
Nalco Guide to Cooling Water Systems Failure Analysis, Second Edition > Intergranular Corrosion
Internal surface of carbon steel ammonia heat exchanger tube after cleaning by glass bead blasting, showing numerous pits and depressions as well as shallow grooves oriented at approximately a 45° angle relative to the longitudinal axis of the tube.
-
Transportation of low-grade thermal energy over long distance by ammonia-water absorption
The solution heat exchanger recovers heat from the weak solution and the ammonia heat exchanger recovers cold from the ammonia vapor, so they are very important for improving the performance.
-
Thermal-Hydraulics for Space Power, Propulsion and Thermal Management System Design > Space Station Mechanical Pumped Loop
… for evaluation in the thermal test bed.9 The heat-acquisition section consists of five HAD's plumbed in parallel: two are cold plates, one is a cold rail, one is a single-phase water/two-phase ammonia heat exchanger , and the fifth is …
-
International Conference on Environmental Systems (ICES) > A Self-Regulating Freezable Heat Exchanger for Use in Spacecraft Thermal Control (AIAA 2013-3418)
A conventional water/ ammonia heat exchanger was replaced with one that could freeze.
-
Structural Pressures Developed During Fill of Complex Systems
HEAT EXCHANGER TEST PROGRAM Water and ammonia heat exchanger fill tests were conducted at the NASA White Sands Test Facility using a Space Station Freedom heat exchanger.
-
Replacement for Internal Active Thermal Control System Fluid Sample Bag Material
The interface between the IATCS and the external active thermal control system (anhydrous ammonia serves as the working fluid) loops is a single barrier water/ ammonia heat exchanger .
Indicates content that may require registration and/or purchase.