Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Watts
Description: Media: Purolite® with color change indicator; total removal capacity: 700 grains; design flow: 1 gpm.
- Trigger: Filter Element / Cartridge
-
Supplier: Watts
Description: Media: Purolite® with color change indicator; total removal capacity: 300 grains; design flow: 1 gpm.
- Trigger: Filter Element / Cartridge
-
Supplier: Watts
Description: Media: Purolite® with color change indicator; total removal capacity: 1,900 grains; design flow: 3 gpm
- Trigger: Filter Element / Cartridge
-
-
Supplier: Watts
Description: Media: Purolite® with color change indicator; total removal capacity: 900 grains; design flow: 2 gpm
- Trigger: Filter Element / Cartridge
-
Supplier: Thermon, Inc
Description: Nuclear Products 3L Filters™ has exceeded the most demanding nuclear filtration requirements for over 40 years. We design and manufacture products for nuclear applications in PWR, BWR and PHWR nuclear reactors. A broad range of standard and custom products includes cartridge filters
- Assembly / Element Type: Cartridge
- Industry Use: Other
- Trigger: Filter Element / Cartridge
-
Supplier: Smart Fog
Description: ducts TS100-1H Capacity: 0 to 1.5GPH Minimum Temperature: 50°F Compressed Air requirement: 2CFM @100psi-150psi Water pressure requirement: 1 to 100 psi Advantages Maintenance free, no moving parts
- Control Tolerance: 1 +/- %
- Features: Integral Control Panel, Self-contained, Water Demineralization
- General Technology: Other
- Placement: Air Handling
-
Supplier: Smart Fog
Description: ducts TS100-2H Capacity: 0 to 1.5GPH Minimum Temperature: 50°F Compressed Air requirement: 2CFM @100psi-150psi Water pressure requirement: 1 to 100 psi Advantages Maintenance free, no moving parts
- Control Tolerance: 1 +/- %
- Features: Integral Control Panel, Self-contained, Water Demineralization
- General Technology: Other
- Placement: Air Handling
-
Supplier: Smart Fog
Description: ducts TS100-2 Capacity: 0 to 1.5GPH Minimum Temperature: 50°F Compressed Air requirement: 2CFM @100psi-150psi Water pressure requirement: 1 to 100 psi Advantages Maintenance free, no moving parts
- Control Tolerance: 1 +/- %
- Features: Integral Control Panel, Self-contained, Water Demineralization
- General Technology: Other
- Placement: Air Handling
-
Supplier: Smart Fog
Description: ducts TS100-1 Capacity: 0 to 1.5GPH Minimum Temperature: 50°F Compressed Air requirement: 2CFM @100psi-150psi Water pressure requirement: 1 to 100 psi Advantages Maintenance free, no moving parts
- Control Tolerance: 1 +/- %
- Features: Integral Control Panel, Self-contained, Water Demineralization
- General Technology: Other
- Placement: Air Handling
-
Supplier: NuAire, Inc.
Description: within 15 minutes. Humidity Control Maintaining humidity is never an issue with any NuAire CO2 incubator. A relative humidity level of up to 95 percent can be achieved in the growth chamber through the use of distilled or demineralized water in the stainless steel pan that
- Carbon Dioxide Range: 0.1000 to 20 (%)
- Chamber Capacity: 5.65 cubic feet
- Computer Interface Options: Serial Interface
- Jacket Type: Water Jacket
-
Supplier: RS Components, Ltd.
Description: -6926 (HANNA HI 38018)- free chlorine. Stock no. 454-6948 (HANNA HI 38019)- total chlorine. Substances Tested = Cl Number of Tests = 200 Sample Size = 10ml Kit Contents = Checker Disc, Chlorine Reagent, Demineralizer Bottle with Filter Cap, Glass Vials, Pipette Maximum Measurement =
-
Description: options include access ports, Explosion Resistant, Quiet Mode, additional shelves, Battery Safety options, Dry Air Purge, Demineralizer Water Filter System and more.
- Chamber Capacity: 2.83 to 35.31 cubic feet
- Configuration: Benchtop / Instrument, Reach-In, Laboratory / Room
- Features: Alarm(s), Chart Recorder, Humidity Control, Programmable, Shelves, Windows
- Humidity Range: 10 to 98 % RH
-
Description: fast change rate. Additional options include access ports, Explosion Resistant, Quiet Mode, additional shelves, Battery Safety options, Dry Air Purge, Demineralizer Water Filter System and more.
- Chamber Capacity: 2.83 to 35.31 cubic feet
- Configuration: Benchtop / Instrument, Reach-In, Laboratory / Room
- Features: Alarm(s), Chart Recorder, Humidity Control, Programmable, Shelves, Windows
- Humidity Range: 10 to 98 % RH
-
Description: -state testing, and fast change rate. Additional options include access ports, Explosion Resistant, Quiet Mode, additional shelves, Battery Safety options, Dry Air Purge, Demineralizer Water Filter System and more. This Chamber with Unique features the middle tranpartent door
- Chamber Capacity: 2.83 to 35.31 cubic feet
- Configuration: Benchtop / Instrument, Reach-In, Laboratory / Room
- Features: Alarm(s), Chart Recorder, Humidity Control, Programmable, Shelves, Windows
- Humidity Range: 10 to 98 % RH
Find Suppliers by Category Top
Featured Products Top
-
. This model includes the most requested features including: EZT-430i Touch Screen Controller RS-232 & Ehternet Computer Interface 3" Access Port Demineralizer filter purifies water and electronic humidity sensor provides accuracy and reliability with (read more)
Browse Environmental Test Chambers and Rooms Datasheets for Cincinnati Sub-Zero Products
More Information Top
-
Phoenix Equipment Corporation | Water Treatment - Other
… Violet (UV) Disinfection Unit Contact Phoenix Equipment Request A Quote 30309348 For Sale Penfield Large Industrial Plant Water Filtration System Contact Phoenix Equipment Request A Quote 31736584 For Sale LA Water Treatment Corp 500 GPM Demineralizer Water Filtration Contact Phoenix Equipment Request …
-
Technology, safety, and costs of decommissioning a reference nuclear fuel reprocessing plant. [Appendices only]
Fuel pool cooler Fuel pool recirculating pumps Filtered demineralizer water return pump Mud filter Fuel pool filter Heat Transfer Plates 316 SS Casings and shafts - 316 SS impellers - bronze 316 SS {casing, impeller and shaft .
-
Retrofitting for Carbon Capture
Makeup Water Demineralizer Multimedia filter , cartridge filter, RO membrane assembly, electrodeionization unit .
-
Federal Register > Friday, November 2, 2001 > [66 FR 55703] Nuclear Management Company, LLC; Duane Arnold Energy Center Environmental Assessment and Finding of...
The staff expects that the process wastes generated from the operation of the reactor water cleanup filter demineralizers and the condensate demineralizers will increase by no more than 10 percent.
-
Federal Register > Friday, January 27, 2006 > [71 FR 4614] Entergy Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc., Vermont Yankee Nuclear Pow...
The increased volume of liquid radioactive waste is due to the increased frequency of reactor water cleanup filter demineralizer and condensate demineralizer backwashes.
-
Federal Register > Thursday, December 20, 2001 > [66 FR 65759] Exelon Generation Company, LLC, Quad Cities Nuclear Power Station, Units 1 and 2; Environmental ...
This would result in additional backwashes of condensate demineralizers and reactor water cleanup filter demineralizers .
-
Federal Register > Thursday, December 20, 2001 > [66 FR 65752] Exelon Generation Company, LLC, Dresden Nuclear Power Station, Units 2 and 3; Environmental Asse...
This would result in additional backwashes of condensate demineralizers and reactor water cleanup filter demineralizers .
-
Federal Register > Friday, November 16, 2001 > [66 FR 57750] Exelon Generation Company, LLC; Dresden Nuclear Power Station, Units 2 and 3 Draft Environmental A...
This would result in additional backwashes of condensate demineralizers and reactor water cleanup filter demineralizers .
-
Federal Register > Friday, November 16, 2001 > [66 FR 57743] Exelon Generation Company, LLC; Quad Cities Nuclear Power Station, Units 1 and 2; Draft Environmen...
This would result in additional backwashes of condensate demineralizers and reactor water cleanup filter demineralizers .
-
Application of Preoxidation Treatment to Suppress 60Co Deposition on Stainless Steel Surfaces of Boiling Water Reactor Primary Cooling Systems
Samples of the reactor water were taken, in plastic bottles, from the plant sampling line installed at the inlet of the reactor water cleanup filter demineralizer .
Indicates content that may require registration and/or purchase.