Products/Services for E-Beam Sterilization Equipment
-
Autoclaves and Sterilizers - (307 companies)Autoclaves are used for applications requiring constant pressure and temperature for long periods of time. Common applications include the sterilization of instruments and polymerization of rubbers and plastics. Autoclaves are used for applications...External ConfigurationInternal ConfigurationHeat Source / Transfer -
Electron Beam Processing Equipment - (26 companies)Electron beam machines, equipment or systems are used to process materials using a very focused energy source with a very small wavelength.
-
Biological Indicators - (42 companies)Biological indicators are used to monitor and evaluate the effectiveness of sterilization. They are designed for use with ethylene oxide gas, dry heat, steam, or radiation. Ethylene oxide gas is used to kill bacteria, mold, and fungi in medical... -
Electron Beam Welding Services - (41 companies)Electron beam welding services use a narrow beam with high energy density to weld metals and alloys with a narrower heat effect zone and deeper penetration compared to most other welding processes. -
Pharmaceutical and Medical Gases - (66 companies)Pharmaceutical and medical gases are pure fluids which are used to synthesize, sterilize, or insulate processes or products which contribute to human health. They are also administered to patients as therapy. Pharmaceutical and medical gases... -
Biotechnology and Pharmaceutical Manufacturing Services - (454 companies)Biotechnology and pharmaceutical manufacturing services activate pharmaceutical ingredients, sterilize biomedical components and materials, validate processes or packaging, and formulate drug or medicinal preparations on a contract basis. How...
-
Lithography Equipment - (65 companies)Lithography equipment transfers circuit or device patterns onto a substrate using a patterned mask and a beam of light or electrons to selectively expose a photoresist layer. Overlay metrology systems align the pattern masks or reticules.
-
Clean In Place (CIP) Systems - (39 companies)Another variation of CIP systems are sanitize-in-place, or SIP, systems that sterilize or sanitize the internal surface of the process equipment. SIP systems are very important in the pharmaceutical and food and beverage industries. Newer CIP...
-
UV Disinfection and UVGI Sanitization Systems - (111 companies)...disinfection systems and UVGI sanitizers. Air treatment systems or UV air purifiers are designed to treat air, gas, or vapor streams. Surface disinfection systems and part sterilizers are designed to destroy microbes on the surfaces of parts or materials...
-
Cold Isostatic Pressing Services - (8 companies)Cold isostatic pressing services apply extremely high pressures using cold isostatic pressing (CIP) or similar technologies to sterilize products or cold compact powders. Supplier specifications include service capabilities, materials processed...
Product News
-
MPF Products, INC.
E-Beam/Crystal Sensor Feedthroughs MPF Products, Inc. designs and manufactures a variety of electrical feedthroughs that assist/support the Thin Film Deposition Equipment marketplace. All of our products are Ultra High Vacuum (UHV) compatible and ideally suited to be mounted on Base Plate Bolts or KF Flanges for vacuum ratings between 1 x10 -5 cc/sec He to 1 x10 -8 cc/sec He. E-Beam / Crystal Sensor Feedthroughs. We offer single pin high amperage designs so you can place a large amount of energy into your source material... (read more)Browse Feedthroughs Datasheets for MPF Products, INC. -
Cri-Tech, Inc.
Cri-plastMP Fluoro-TPE/V & TPX (e-beam xlinkable) Formulation Development, Custom Rubber and Plastic Compounding, Specialty Toll Manufacturing & Color development. Cri-Tech's state of the art facility includes both internal and twin-screw mixing capabilities. Cri-Tech 's "clean " mixing operation provides overall contamination control and allows for compounding of nanomaterials including nanotubes and graphene. Our diverse manufacturing capabilities currently produce Fluoro-TPEs, TPVs, E-beam cross-linkable F-TPX compounds, Specialty... (read more)Browse Elastomers and Rubber Compounds Datasheets for Cri-Tech, Inc. -
Hamilton Company
Syringe Sterilization and Disinfecting Guide Are you curious whether your Hamilton syringe can be sterilized and disinfected via ethylene oxide, autoclavation, or chemical disinfectants? Consult this table of syringe terminations, syringe needles, and tubing types to learn the possible ways to sterilize and disinfect your Hamilton syringe: (read more)Browse Chemical Additives and Agents Datasheets for Hamilton Company -
Portescap
Motor Sterilization and Autoclaving Sterilizable Motor Solutions. Disinfection Through Medical Washer. Medical washers (sometimes referred to as medical dishwashers or thermal disinfectors) are automated machines used to wash and disinfect medical devices and remove bioburden prior to sterilization. The process introduces hot water and specialized high pH cleaning detergents to the wash chamber making the environment especially harsh. Portescap performs in-house washer durability and performance testing on motors. On most motors... (read more)Browse Brushless Motors Datasheets for Portescap -
Portescap
Sterilizable Motors for Surgical Hand Tools Surgical Motor Solutions. Custom Engineered for Critical Performance. Powered surgical hand tools rely on high performance mini motors for optimal surgical outcomes. Portescap has over 20 years of experience designing and developing high-quality sterilizable motor solutions for your most performance-critical surgical power tools. From a standard offering to a fully customized solution, you have a wide variety of choices. Our design engineers will work with you hand in hand to help you find... (read more)Browse Brushless Motors Datasheets for Portescap -
Electro Optical Components, Inc.
SMD UV Sensors - Great for Sterilization UV Sensor SMD packages available are: Ceramic SMD Package with UV Quartz Window and UV sensor for high energy, robust applications that require lower cost. SiC Ceramic SMD Package with UV Quartz Window with the BEST high energy performance. The smaller size make these 2 package options ideal for applications where size is a concern. Use the GaN GUVA-S12GD-C for cost sensitive applications like wearable UV detectors, UV detectors in portable devices like phones and watches and other high volume... (read more)Browse UV Sensors Datasheets for Electro Optical Components, Inc. -
Electro Optical Components, Inc.
Smartphone UV Meter for UV Curing & Sterilization The Smart UV Checker is an ideal portable system for UV intensity measurement. You choose the style of sensor, corded or Bluetooth. The Smart UV Checker app (for your cellphone) gives you flexibility in how you measure the UV intensity. EOC also offers a variety of Multi-Function Portable UV Radiometers. These include: Cellphone based Smart UV Checker. Panel Mounted Units. Portable Meters. Large Outdoor UV Index Meters (read more)Browse UV Sensors Datasheets for Electro Optical Components, Inc. -
Arnold Magnetic Technologies
Reliable titanium supplier - outstanding quality options. Customers rely on us as a thin-rolled titanium foil supplier. Ti is used in applications that demand high performance and consistent quality. These applications include fabrication of electron beam equipment for food sterilization, vulcanizing, and a variety of industrial uses; design and building of flight and aerospace vehicles; energy-related applications such as solar panels; speaker components; and medical device enclosures. Titanium 's corrosion resistance means that the material... (read more)Browse Metal Strip Datasheets for Arnold Magnetic Technologies -
New England Tubing Technologies
Lining materials for your Tubing application applications, and is slightly more rigid than FEP. Properties include being nonreactive and hydrophobic, with a very low coefficient of friction, excellent lubricity, and good insulating properties. PTFE is EtO and autoclave sterilizable but cannot be sterilized using Gamma or E-beam technologies. It requires etching and is typically the highest cost option. Other materials like ETFE and PFA may also be considered for tube linings. ETFE offers superior tensile strength and stiffness with good... (read more)Browse Plastic Tubing Datasheets for New England Tubing Technologies -
New England Tubing Technologies
What Tube Lining Material is Right for You? applications, and is slightly more rigid than FEP. Properties include being nonreactive and hydrophobic, with a very low coefficient of friction, excellent lubricity, and good insulating properties. PTFE is EtO and autoclave sterilizable but cannot be sterilized using Gamma or E-beam technologies. It requires etching and is typically the highest cost option. Other materials like ETFE and PFA may also be considered for tube linings. ETFE offers superior tensile strength and stiffness with good... (read more)Browse Tubing Datasheets for New England Tubing Technologies
Conduct Research
Most people will never see an application that has lubrication problems due to radiation (except for Nuclear Power Plants). But radiation is also used in many industries for sterilization. Cobalt 60 and E-Beam are commonly used to sterilize health care and surgical products, cosmetics, spices...
...of pharmaceutical aseptic processing has been the popularization of low-energy electron beam technology for sterilization --the topic generated quite a bit of buzz at 2008 's ISPE annual meeting in Boca Raton, as well as at Pack Expo in Chicago. While high-energy electron beams have been used in a variety...
MPE Group USA, Jongia Div. Nonchemical Sterilization Process for Nonwovens E-Beam offers a non-chemical process for the bioreduction and sterilization of nonwovens, permitting manufacturers and packagers to assure product integrity without the use of alcohol or chemical additives. The process...
-
Effects of sterilization on optical and mechanical reliability of specialty optical fibers and terminations
Certain fibers with non-fluorinated coatings may still be considered sterilizable with E - beam or gamma radiation once the induced losses fall within the allowed attenuation budget of the equipment .
-
Damage of office supply, personal use items, and over-the-counter medical devices after sterilization by ethylene oxide gas, electron beam, and gamma radiation.
The effects of three sterilization methods (i.e. ethylene oxide gas [EO], electron beam [ e - beam ] radiation, and gamma radiation) were evaluated for a variety of office supply and equipment , personal use items, and over-the-counter medical devices.
-
Reducing the Risk of Contamination of Sterile Parenteral Products via Ready-to-Use Closure Components
& Qualification of the equipment & Resistance (D) value of the material to be sterilized & Thermal profiling of the chamber & Heat penetration of … … biological indicators & Air removal Ionizing radiation (both electron beam ( e - beam ) and gamma radiation) have …
-
China - Classification Catalogue for Occupational Disease Hazards, issued by the Ministry of Health March 28, 2002 and effective May 1, 2002.
… produce the 16 traffic transportation equipment industry vessel electrical installation, marine instrument assembly, nuclear reactor installation, 17 radioactive substance transportation electrons and communication equipment industry hit hyperbaric old … … industry Υ irradiation processing, electron beam irradiation processing, radiative sterilization , radiative food fresh-keeping …
-
Sterile Product Development
The filling process for PFS (see Fig. 10.4) and cartridges consists in: • Sterilization of the external part of the tubs, usually done by e - beam but recently a plasma sterilization has been installed by GSK in UK. Some companies such as Vetter have developed a cascade system which avoids expensive investments in sterilization equipment .
-
http://www-pub.iaea.org/MTCD/publications/PDF/Pub1313_web.pdf
—Facility for thermoshrinkable tube production according to an INCT licence, located in the factory, equipped with an electron accelerator ILU-6 type, electron energy 2 MeV and 20 kW beam power (1984); —Radiation sterilization facility equipped with a microwave linac Elektronika 10/10 … E - BEAM STERILIZATION SERVICE CENTRE IN POLAND .
-
Radiation sources of technique and medicine
The electron radiation beams are generated with scanned compartment beams. Because of the lesser penetration ability, the electron sterilization installations are used for the sterilization of less extended materials.
-
Integrated Biomaterials Science
The main advantages of E - beam sterilization are speed, precision, and flexibility. The high cost of the equipment restricts its use to those com- panies who have a large …
-
Vaulter Clinical dictionary
… resonance measure; principle: s.u. electron spin Elekltrolnenlstelrillilsaltion f (E β-rays of sterilization): Sterilisa-tion✫ with β- beams; f is used v.a. Elekltrolnenlstrahlltolmolgralphie for the sterilization of catheters, implants and … … electron-ray tomography): Syn: electron beam tomography; innovative technique, by … … nt (E electronystagmogram): through Elektronystagmographie obtained recording Elekltrolnysltaglmolgraph m (E electronystagmograph): Syn: Elektronystagmograf; apparatus to the Elektronystagmographie …
-
JAMA Network | JAMA | Use of Electron-Beam Sterilized Hemodialysis Membranes and Risk of Thrombocytopenia
… possibility of factors specific to a single unit, such as dialysis solutions and equipment supply, is much … After the discontinuation of e - beam sterilized dialyzed membranes, the number of patients with postdialysis thrombocytopenia declined.
Indicates content that may require registration and/or purchase.