Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Cole-Parmer
Description: Chip Fleet Pro logger records up to 1200 hours of data before overwriting earliest trip data Logs time, date, and distance traveled for each trip • Speed is logged up to every second • Accident logs capture the critical 20 seconds during a hard-braking event • CarChip Fleet Pro
-
Supplier: HORIBA Instruments, Inc.
Description: Each TITAN test stand is optimally designed for categories of combustion engines. The TITAN range of engine test systems from HORIBA enables you to add dependable testing capacity in the shortest possible time. All systems are supplied pre-tested and pre-assembled on a mounting plate
- Features: Integrated Data Logger
- Form Factor: Floor Mount
-
Supplier: HORIBA Instruments, Inc.
Description: Each TITAN test stand is optimally designed for categories of combustion engines. The TITAN range of engine test systems from HORIBA enables you to add dependable testing capacity in the shortest possible time. All systems are supplied pre-tested and pre-assembled on a mounting plate
- Features: Integrated Data Logger
- Form Factor: Floor Mount
- Online Test Parameters: Power
-
-
Supplier: Cole-Parmer
Description: quick acceleration. Perfomance parameters monitored include emissions readiness, RPM, throttle position, engine load, fuel pressure, fuel system status, battery voltage, timing advance, coolant temperature, air flow rate, intake air temperature, intake manifold pressure, short-term
Find Suppliers by Category Top
Featured Products Top
-
We had a customer recently request a right angle spiral bevel gear design that was to be incorporated into a hybrid diesel/electrical power package to drive a bus. Much like a train power supply, the diesel engine was to drive a generator that (read more)
Browse Gearboxes and Gearheads Datasheets for DieQua Corporation
Conduct Research Top
-
Exhaust System Monitoring for Diesel Engines
Incoming EPA regulations such as RICE NESHAP have made particulate emissions reduction important in the diesel engine industry. To help manufacturers achieve compliance, CAS DataLoggers has provided a dataTaker DT82I industrial data logger to monitor a new catalytic converter system for values
-
Recording Road Surfacing Data to Prove Process Efficiency
. This data would have to be collected from sensors recording several different parameters including the temperature of the bitumen, the surrounding air, engine RPM, road speed, and more.
More Information Top
-
Time Series Modeling for Analysis and Control
These data are usually obtained through a motion gyro (roll, pitch), an autopilot (yaw, rudder), and a main engine data logger (propeller RPM , thrust, torque, etc.).
-
Practical Race Car Data Acquisition Fast Track
…The most common set-ups for Engine RPM and Speed/MPH data acquisition • The procedures for acquiring and analyzing Engine RPM and Speed data • How to interpret the most common data logger outputs for both Engine RPM and Speed data •…
-
In-Use Evaluation of Fuel Economy and Emissions from Coal Haul Trucks Using Modified SAE J1321 Procedures and PEMS
…electric generation system engine speed signal for rpm comparisons 3 Diesel-electric generation system bhp signal for ECM bhp comparisons Analysts first aligned the ECM and data logger 1-second data , based on rpm spikes or other engine events during load box…
-
Development of Delhi Driving Cycle: A Tool for Realistic Assessment of Exhaust Emissions from Passenger Cars in Delhi
During the study, the speed-time data collection through non-contact type optical speed sensor with real-time data logger , gear position, real-time vehicle position through GPS, engine rpm and recording of on-road fuel consumption data for both diesel as…
-
Evaluation of Camry HS-CAN Pre-Crash Data
The data logger reached the sensor rpm limit while the HS-CAN continued to report higher engine speeds.
-
NAVAL
POSTGRADUATE
SCHOOL
Data logger analysis of changes in RPM , oil pressure, turbo oil temperature, and propeller pitch subsequent to original two second RPM drop indicate the engine was failing over a period of 15 minutes.
-
High-Powered Engine Testing on a Navy Patrol Boat
The CANgate, CANbus to ASCII gateway captured the real-time data monitored and recorded on J1939 bus from the ECU ( engine temperatures, RPM , throttle settings, load, etc.) and relayed that information onto the dataTaker logger .
-
Exhaust System Monitoring for Diesel Engines
To help manufacturers achieve compliance, CAS DataLoggers has provided a dataTaker DT82I industrial data logger to monitor a new catalytic converter system for values such as incoming … outgoing exhaust temperature, differential pressure in the converter chambers, and the diesel engine 's RPM .
-
Underground Mine Communications & Monitoring |
The system, which leverages vehicle data loggers and sensors manufactured by ISAAC Instruments Inc., can also provide the maintenance team with real-time alarms as triggers for condition-based preventive maintenance: Excessive rpm , high engine coolant temperature/low engine coolant level, high engine…
-
Timing and Synchronization of the Event Data Recorded by the Electronic Control Modules of Commercial Motor Vehicles - DDEC V
The VBOX III 100 Hz GPS Data Logger was set to record parameters from the J1939 CAN data broadcast by the DDEC V ECM concerning the … clutch pedals (on/off), the percent accelerator pedal position, engine speed ( RPM ), and vehicle speed (km/h).
Indicates content that may require registration and/or purchase.