-
Supplier: ValueTronics International, Inc.
Description: The 7072 is a Switch Card from Keithley. Data loggers, or data recorders, collect information over time for a variety of purposes. A data logger uses internal memory and sensors to gather and document information on a 24-hour basis. Receive an accurate and comprehensive picture of the
-
Supplier: ValueTronics International, Inc.
Description: ExceLINX™ -1A datalogging software 1-Year Warranty Accessories Supplied LabVIEW, LabWindows/ CVI, Visual Basic, and C/C++ drivers Manual Model 1751 Safety Test Leads The Keithley 2701 combines precision measurement, switching
-
Supplier: ValueTronics International, Inc.
Description: The 240A is a 65 Watt DC Power Supply from Keithley. Supplies DC Voltage and Current to test, design, and troubleshoot electric and electronic circuits. Applications include Burn In, QA, ATE, Research, Design, and Education to name a few. Additional Features: Voltage
- DC Output Power: 65 watts
-
-
Supplier: ValueTronics International, Inc.
Description: The 2700 is a Data Logger from Keithley. Data loggers, or data recorders, collect information over time for a variety of purposes. A data logger uses internal memory and sensors to gather and document information on a 24-hour basis. Receive an accurate and comprehensive picture of the
Find Suppliers by Category Top
More Information Top
-
The Influence of Angiography Table Shields and Height on Patient and Angiographer Irradiation During Interventional Radiology Procedures
The scattered radiation to the operator was measured with a survey meter designed for scattered radiation measurements ( Keithley Model 36155 Survey Meter).
-
Radiation Safety for the NOMAD™ Portable X‐Ray System in a Temporary Morgue Setting *
Exposures were taken through the Lucite phantom and measured using the Keithley Radiation Survey Meter (Keithley Instruments, Inc., Cleveland, OH) (Fig. 4) in the integrate mode on a scale of 0–200 micro-Roentgens (lR).
-
Flat-panel detector-based cone beam volume CT breast imaging: detector evaluation
The mean signals were measured in ADC units within the region of 20x20 pixels and the input exposures were the mean value under 100 x-ray shot pulses measured by a Keithley 35050A Dosimeter (Inovision Radiation Measurements , Cleveland, OH) and 150 cc …
-
Real-time flat-panel detector-based-volume tomographic angiography imaging: detector evaluation
The mean signals were measured in ADC units from the region of2Ox2O pixels and the input exposures were measured using a Keithley 35050A Dosimeter (Inovision Radiation Measurements , Cleveland, OH) and 1 50 cc ionization chamber at the center of the FPD entrance …
-
Digital Radiography for Quality Determination of Small Agricultural Products: Development and Calibration of Equipment
A Dosimeter (Model: Keithley 35050, Inovision Radiation Measurements , Cleveland, OH) with 150-cc ion chamber (Model: 77957 H-60) was used to measure dose rate in mR/min.
-
Patient radiation exposure during pediatric cardiac catheterization
1 Keithley Instruments Inc., Radiation Measurements Divi- sion, Cleveland, OH, USA 2 Simpson Electric Co., Elgin, IL, USA .
-
DELAY OF CELL DIFFERENTIATION IN Anabaena aequalis CAUSED BY UV‐B RADIATION AND THE ROLE OF PHOTOREACTIVATION AND EXCISION REPAIR
The intensities of the radiation sources were measured with a Keithley voltmeter and a sensitive thermopile calibrated against a Kipp and Zonen (Model CAI) factory calibrated thermopile.
-
Preliminary experience with acquisition of 20482 fluorographic images
Radiation exposure rate was measured using Keithley pancake type ionization chambers whose response is independent of kVp over the diagnostic range.
-
UV response of a transition metal oxide diode
The signal current produced by the detector when in the radiation beam was measured using a Keithley 6487 picoammeter.
-
Diamond radiation sensors for medical applications
The dark current and the radiation response was measured with a Keithley 617 electrometer.
Indicates content that may require registration and/or purchase.