Products/Services for LC PAL Autosamplers
-
Autosamplers - (140 companies)Autosamplers are automated sample loaders, usually robotic, used with chromatography, atomic absorption, and other analytical technologies. Autosamplers are designed especially for laboratories that process large numbers of samples on a routine...Injection StyleInjection MechanismTemperature Control -
Device Programmers - (97 companies)Device programmers are used to program nonvolatile memory such as microcontrollers, erasable programmable read-only memory (EPROM), programmable logic devices (PLDs), programmable array logic (PAL), generic array logic (GAL) and other electrically... -
Fiber Optic Connectors - (514 companies)...the size of standard connectors, resembling a smaller version of the SC. This design increases packaging density by 50% with its narrow footprint and push/pull snap-lock design. LC connectors are used in private and public networks, and are gaining... -
Device Programming Services - (99 companies)Device programming services companies program FPGAs, ASICs, GALs, PALs, EPROMs and other electronic components. This programming is sometimes performed at facilities that assemble PCBs. Device programming services program field-programmable gate... -
GC Columns - (82 companies)Gas chromatography columns (GC columns) are of two types: packed and capillary. Solutes to be measured travel through the column at a rate primarily determined by their physical properties, and the temperature and composition of the column. -
Fiber Optic Ferrules - (27 companies)...equipment. There are many different types of fiber optic connectors. Examples include biconic, D4, ESCON, FC, FDDI, LC, loopback, MTP, MT-RJ, MU, SC, SMA and ST. Straight tip (ST) connectors, the most popular connector type for multi-mode networks...
-
Simple Programmable Logic Devices (SPLD) - (59 companies)...fuses or non-volatile memory cells (EPROM, EEPROM, FLASH, and others) to define the functionality. These devices are also known as: Programmable array logic (PAL). Generic array logic (GAL). Programmable logic arrays (PLA). Field-programmable logic...
-
Vials - (195 companies)...that the vial can hold. A dram is a unit of fluid measurement common to laboratory applications; one dram is about 3.7 mL. The outer diameter of the vial is important in applications where an autosampler would be used. The height of the vial is important...
-
Scan and Video Converters - (76 companies)System Committee (NTSC) standard or Phase Alternative Line (PAL) video. The high definition television (HDTV) aspect ratio is 16:9. Resolution. In addition to input signal type, scan and video converters differ in terms of resolution. There are five...
-
Resonators - (231 companies)...be manufactured in small size chips or dies. Resonators with quartz crystals or passive electronic components are also available. RC resonators include resistors (R) and capacitors (C). LC resonators include inductors (L) and capacitors (C). Performance...
Product News
-
Hamilton Company
C-Line Syringe Optimized for CTC Autosamplers tip and minimizes wear. Models are available for all CTC PAL LC and GC autosamplers. "Syringe wear and tear affects productivity in all types of labs," explained Amber Ratcliff, distributor relations manager for Hamilton. "We've designed our new C-Line Syringes to deliver the best quality and longest life on the market.". The C-Line syringes are available in all volumes, from 5 uL to 1,000 uL. Hamilton Company is a leading worldwide supplier of precision liquid handling equipment, laboratory... (read more)Browse Syringes and Needles Datasheets for Hamilton Company -
Hamilton Company
S-Line Syringes Economical choice for CTC PAL S-Line syringes are the cost-effective choice for CTC PAL autosampler applications. Fast injection speeds in GC analyses put considerable stress on syringe plungers and, as plungers wear the stresses increase, leading to broken syringes and unnecessary downtime and wasted money when samples cannot be analyzed. Hamilton syringes employ a fitting process that precisely fits each plunger to the matching barrel. This produces a plunger with minimal drag force and optimal wear characteristics... (read more)Browse Syringes and Needles Datasheets for Hamilton Company -
Hamilton Company
S-Line Syringes economical for CTC PAL HPLC S-Line syringes deliver great performance in everyday use for HPLC injections at an exceptional value. The Gastight version of the S-Line syringe is an ideal choice for HPLC sample injections. It incorporates a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit in the glass barrel, the tip wipes the interior of the syringe barrel free of sample, minimizing sample carryover. This feature is particularly useful with heterogeneous samples as it reduces the chance... (read more) -
Hamilton Company
GC Autosampler Syringes Hamilton maintains a large catalog of replacement syringes for the most popular GC autosamplers. Our syringes are handmade with an unmatched attention to detail. The manufacturing process and quality assurance procedures ensure that every syringe we sell will provide superior accuracy and precision as well as cycle life. Choose the sub category that is associated with your autosampler manufacturer to find the syringes available for your instrument. CTC / LEAP Technologies GC Autosampler... (read more)Browse Syringes and Needles Datasheets for Hamilton Company -
Hamilton Company
Spark Holland Autosampler Syringe Line The World Famous Hamilton Syringe is now available for your Spark Holland AutoSampler!!! * Rugged polytetrafluoroethylene (PTFE) plunger tip for GASTIGHT (R) applications * Economically designed to give true value at an affordable price * Strictly machined tolerances for reproducible results from injection-to-injection * Hamilton glass barrel surface finish for superior syringe life and excellent cost savings * Nothing says quality in a syringe like the Hamilton Company name. Spark Holland... (read more)Browse Syringes and Needles Datasheets for Hamilton Company -
SST Sensing Ltd.
Oxy-LC Interface Board The Oxy-LC Interface Board provides a convenient platform for connecting, evaluating, and integrating SST oxygen sensors into development systems. Designed to support efficient testing and system configuration, it enables engineers to quickly access sensor outputs and assess performance. Ideal for OEM development and prototyping, the Oxy-LC Interface Board helps reduce integration time and supports system validation prior to final product design. It is a practical tool for laboratory testing... (read more) -
Anatech Electronics, Inc.
260 MHz LC Lowpass Filter 260 MHz LC Lowpass Filter. Electrical specifications. Cutoff Frequency (Fc): 260 MHz. Passband: DC-200 MHz. Insertion loss: 0.5 dB @ 200 MHz. Return loss: >15 dB. High Side Rejection: 60 dB from 300-1000 MHz. Power Handling: 10 W. Mechanical. Connector Type: SMA (F). Dimensions: 1.5 x 0.75 x 0.5 inches. Environmental. Operating Temperature: 0 to +85 deg.C. Storage temperature: -65 to +95 deg.C. Shock: 20 G 's, 1/2 sine, 11ms. Vibration: 10 G 's, 10-2000Hz. Relative Humidity: 0-95%. Follow us... (read more)Browse RF Low Pass Filters Datasheets for Anatech Electronics, Inc. -
Anatech Electronics, Inc.
10 MHz LC Bandpass Filter 10 MHz LC Bandpass Filter. The 10 MHz LC Bandpass Filter is designed for precise frequency selection with excellent out-of-band rejection. Centered at 10 MHz, it offers a >200 kHz 3 dB bandwidth and a 9.9 -10.1 MHz passband, ensuring stable signal performance with low VSWR. Housed in a compact SMA-connected package, it is built to withstand harsh environmental conditions, including wide temperature ranges, shock, and vibration, making it suitable for demanding RF applications. Electrical... (read more)Browse RF Band Pass Filters Datasheets for Anatech Electronics, Inc. -
Waytek, Inc.
Littelfuse High Voltage LC 10EV Fuse LC 10EV fuses come in six configurations. Each version of the cylindrical high-current fuse employs diffusion pill technology to provide time-delayed protection to high-voltage accessory circuits in EVs and hybrid passenger vehicles. M5 mounting holes for bolt-down fuses (4.5 Nm +-1 Nm ISO prescription). Interrupting ratings of 20 kA at 500VAC and 500VDC. Time-delayed protection to circuits in electric vehicles. Operating Temperature: -40 C (-40 F) to 125 C (257 F). Tin-plated copper alloy... (read more)Browse Fuses Datasheets for Waytek, Inc. -
Anatech Electronics, Inc.
401 MHz/ 432 MHz LC Diplexer 401 MHz / 432 MHz LC Diplexer. Duplexers & Diplexers. Anatech Electronics offers Duplexers and Diplexers in different technologies, from cavity duplexers, LC diplexers and duplexers, Ceramic duplexers, and SAW duplexers. Each technology has its advantages and disadvantages ranging from the frequency range, to power handling, size, and other parameters that are better discussed in our technical write-up on various filters and their advantages and disadvantages in Filter Design Guide... (read more)Browse RF Diplexers, Duplexers, and Multiplexers Datasheets for Anatech Electronics, Inc.
-
Routine high‐precision analysis of triple water‐isotope ratios using cavity ring‐down spectroscopy
Methods We use a Picarro L2140‐i cavity ring‐down spectroscopy analyzer with discrete liquid injections into an A0211 vaporization module by a Leap Technologies LC PAL autosampler .
-
Routine high-precision analysis of triple water-isotope ratios using cavity ring-down spectroscopy.
We use a Picarro L2140-i cavity ring-down spectroscopy analyzer with discrete liquid injections into an A0211 vaporization module by a Leap Technologies LC PAL autosampler .
-
Influence of synoptic weather events on the isotopic composition of atmospheric moisture in a coastal city of the western United States
[14] The isotope analysis of liquid water samples was performed on a DLT-100 Liquid Water Isotope Analyzer (LWIA, LGR Inc.) coupled to a LC PAL autosampler sys- tem (CTC Analytics AG, Zwingen, Switzerland) in the Ecosystem Ecology Lab at San Diego…
-
Suitability of tetrahydofuran as a dopant and the comparison to other existing dopants in dopant‐assisted atmospheric pressure photoionization mass spectrometr...
Samples were injected with a LC PAL autosampler (LEAP Technologies, Carrboro, NC, USA).
-
Multiplexed labeling of viable cells for high‐throughput analysis of glycine receptor function using flow cytometry
Liquid-handling was performed with an LC PAL autosampler (CTC Analytics) using a 100 ll syringe.
-
Glucosinolates on the leaf surface perceived by insect herbivores: review of ambiguous results and new investigations
…were analysed at Wa¨denswil with a API 4000 triple- quadrupol mass-spectrometer (Applied Biosystems, Rotkreuz) with a Turbo Ion Spray-source linked to a binary HPLC pump (Agilent 1100 Series, Agilent Technologies Inc., Basel) and a LC PAL autosampler (CTC Analytics, Zwingen).
-
The effect of alkylamine additives on the sensitivity of detection for paclitaxel and docetaxel and analysis in plasma of paclitaxel by liquid chromatography–t...
The quantitative assay was validated using a liquid chromatography–mass spectrometry (LC/MS) system, consisting of an HP 1100 Pump (Waldbronn, Germany), a LEAP Technologies CTC Analytics LC PAL autosampler (Carrboro, NC, USA), and an Applied Bio- systems API 3000 triple quadrupole mass spectrometer…
-
Advantages of atmospheric pressure photoionization mass spectrometry in support of drug discovery
Samples were injected with a LC Pal autosampler from LEAP Technol- ogies (Carrboro, NC, USA).
-
Eggs of cabbage root fly stimulate conspecific oviposition: Evaluation of the activity and determination of an egg-associated compound
…were analysed on a API 4000 mass spectrometer (Applied Biosystems, Applera Europe, Rotkreuz, Switzerland) equipped with a Turbo Ion Spray source, coupled to a binary pump (1100 Series, Agilent Technologies Inc., Basle, Switzerland) and a LC PAL autosampler (CTC Analytics, Zwingen, Switzerland).
-
Microbial diversity of L oki's C astle black smokers at the A rctic M id‐ O cean R idge
…the Geological Institute of the ETH Zurich using high- performance liquid chromatography/atmospheric pressure chemical ionization–mass spectrometry (HPLC/APCI–MS) with a Thermo Surveyor LC system coupled to an LCQ Fleet ion trap mass spectrometer equipped with a PAL LC autosampler and Xcalibur software, as…
Indicates content that may require registration and/or purchase.