Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Dupont Water Solutions
Description: AMBERJET™ UP6150 is a fully regenerated mixed bed of cation and anion exchange resins intended for use in high purity water systems after reverse osmosis.
- Filter Medium Material: Anion Exchange Resin, Cation Exchange Resin, Mixed Resin
-
Supplier: Dupont Water Solutions
Description: AMBERJET™ UP6040 is a semi-conductor grade ion exchange resin mixed bed specifically designed for use in non regenerable final polishing units in the highest purity water treatment applications.
- Filter Medium Material: Anion Exchange Resin, Cation Exchange Resin, Mixed Resin
- Maximum Temperature: 140 F
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR ANION-CATION BALANCE OF MIXED BED ION-EXCHANGE RESINS
-
-
Supplier: Serfilco, Ltd.
Description: bath replenishment. Concentrated regenerate can be chemically treated for disposal or possible recovery. For WATER PURIFICATION Units provide high quality deionized water when fi lled with a strong base mixed-bed resin. Product water is low in dissolved solids, CO2 and silica, with a
-
Supplier: Serfilco, Ltd.
Description: is suitable for discharge or bath replenishment. Concentrated regenerate can be chemically treated for disposal or possible recovery. Units provide high quality deionized water when filled with a strong base mixed-bed resin. Product water is low in dissolved solids, CO2 and silica,
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR ANION-CATION BALANCE OF MIXED BED ION-EXCHANGE RESINS - INCLUDES STANDARD + REDLINE (PDF)
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 100 g, biotechnology grade ion exchange resin, self-adsorbed form, 8% crosslinkage, 50-100 dry mesh size, 180-425 µm wet bead size, ~1,000 MW limit AG 501-X8 Mixed bed resins are used for deionizing water or other non-ionic substances such as urea, acrylamide,
- Filter Medium Material: Anion Exchange Resin
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 100 g, biotechnology grade ion exchange resin, H+ + OHâ form, 8% crosslinkage, 20-50 dry mesh size, 300-1,180 µm wet bead size, ~1,000 MW limit AG 501-X8 Mixed bed resins are used for deionizing water or other non-ionic substances such as urea, acrylamide,
- Filter Medium Material: Anion Exchange Resin
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 500 g, analytical grade ion exchange resin, self-adsorbed form, 8% crosslinkage, 50-100 dry mesh size, 180-425 µm wet bead size, ~1,000 MW limit AG 501-X8 Mixed bed resins are used for deionizing water or other non-ionic substances such as urea, acrylamide,
- Filter Medium Material: Anion Exchange Resin
-
Supplier: Bio-Rad Laboratories, Inc.
Description: 500 g, analytical grade ion exchange resin, H+ + OHâ form, 8% crosslinkage, 20-50 dry mesh size, 300-1,180 µm wet bead size, ~1,000 MW limit AG 501-X8 Mixed bed resins are used for deionizing water or other non-ionic substances such as urea, acrylamide, formamide
- Filter Medium Material: Anion Exchange Resin
-
Supplier: ASTM International
Description: 1.1 This test method determines the ratio between the equivalents of anion-exchange capacity and the equivalents of cation-exchange capacity present in a physical mixture of salt-splitting anion-exchange material and salt-splitting cation-exchange material. 1.2 The values
-
Supplier: ASTM International
Description: 1.1 This test method determines the ratio between the equivalents of anion-exchange capacity and the equivalents of cation-exchange capacity present in a physical mixture of salt-splitting anion-exchange material and salt-splitting cation-exchange material. 1.2 The values
-
Supplier: ASTM International
Description: 1.1 This test method determines the ratio between the equivalents of anion-exchange capacity and the equivalents of cation-exchange capacity present in a physical mixture of salt-splitting anion-exchange material and salt-splitting cation-exchange material. 1.2 The values
-
Supplier: Marmon Industrial Water LLC
Description: compared to mixed bed DI. All this is accomplished using a combination of selective ion exchange membranes, ion exchange conductive resins, and electricity to remove ions from water rather than costly hazardous chemicals. Typical Applications Power Generation:
- Continuous Flow Rate: 15 to 440 GPM
- Market: Industrial, Other
- Removal Application: Demineralization, Ultra Pure Water, Purification
-
Description: Culligan® Pro Series deionizers are part of a multiple process treatment system that produces high quality water required for specialized applications. A flexible configuration of mixed-bed or strong acid-base resin tanks is simple to manage, and you have the option to automatically or
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: exchanging H+ and OH–. Their uniform and compact mixed bed ensures reliable desalination and optimal utilization of the resin material, reducing conductivity by up to < 0.1 µS/cm. The arium® line also includes conductivity meters for checking the quality of product water.
- Market: Food / Medical / Sanitary
- Removal Application: Water Softening
Find Suppliers by Category Top
Featured Products Top
-
Custom thermoset molding services range across a variety of industries, each with a unique set of materials and part specifications. Both the resin transfer molding (RTM) process and reaction injection molding (RIM) process offer specific capabilities that can be applied to virtually any project (read more)
Browse Datasheets for Osborne Industries, Inc. -
UV bulbs have distinct differences and are tailored to meet your application's specific needs. Their usage abilities range from killing COVID to curing resin. UV bulbs generally contain an inert gas mixed with mercury. UV light is produced when electricity reacts with mercury, and the pressure (read more)
Browse UV Disinfection and UVGI Sanitization Systems Datasheets for AirClean Systems
Conduct Research Top
-
The Advantages of Uniform Particle Sized Ion Exchange Resins (.pdf)
styrene-divinylbenzene resins in the 40's. The production of resins in a stirred reactor results in the formation of resin beads with a polydispersed particle-sized distribution. Although new resin product development has been limited by this manufacturing process, ion exchange process application
-
Development of Ion Exchange Resins with Ultra-Low Residuals for Condensate Polishing Applications (.pdf)
Nuclear power plants need to minimize corrosion and corresponding deposition throughout steam/water circuits. Condensate polishers containing mixed beds of ion exchange resins play a vital role in reduction of impurities in water circulated through these polishers.
More Information Top
-
Estimation of the surface sulfur content of cellulose nanocrystals prepared by sulfuric acid hydrolysis
The constancy of the apparent %S value for samples treated with the cation exchange resin confirmed that the sulfate esters were in protonated form from the start, whereas the mixed bed resin exchanged the protons associated with the CNCs to an increasing …
-
Ion Exchange & Chromatographic Resins
Tasaki, S. (to Rohm and Haas Company), " Mixed Bed Exchange Resin System and Method of Preparation" (May 11, 1999 .
-
Sustainable Development of Sea-Corridors and Coastal Waters
The water was then treated with reverse osmosis and finally with ion exchange, consisted of cat- ion, anion, and mixed bed exchange resins .
-
Expansion Rates of Phragmites australis Patches in a Partially Restored Maine Salt Marsh
For each resin bag, 15 g of mixed bed resins [J.T. Baker Mixed Bed Exchange Resin , IONAC NM-60 H+ /OH− Form, Type 1, Beads (16–50 mesh)] were placed into a precut sec- tion of nylon stocking.
-
Changes to the N cycle following bark beetle outbreaks in two contrasting conifer forest types
Resin bags in the base of each core were constructed using 20 g of ion exchange resin (IONAC NM-60 mixed bed exchange resin , strong acid/strong base; sulfonated alkyl quaternary ammonium polystyrene; J.T. Baker #JT4631-1) tied inside a piece of …
-
Plant Chromosome Engineering
FA (formamide) for hybridization solution: Deionize formamide of highest grade by stirring 5 g of in vacuo dried mixed bed exchange resin AG 501-X8(D), molecular biology grade (BIO-RAD) in 100 ml of formamide for ~3 h or until pH …
-
Morphological, Physicochemical and Structural Characteristics of Oxidized Barley and Corn Starches
For the debranched starch samples the method is described to continuation but a mixed bed exchange resin (IONAC NM-60, J.T. Baker, Phillipsburg, NJ) was added to the debranched solutions to eliminate the interference from the buffer prior to HPSEC analyses.
-
Association of a novel high oxygen affinity haemoglobin variant with δβ thalassaemia
nating anions by chromatography on a mixed bed exchange resin (Dowex AG 50-1x8, Bio-Rad Laboratories, Richmond, Calif.).
-
Inulin hydrolysis to fructose by a novel catalyst
Inulin solutions of known initial concentrations were prepared and treated with cation, anion, and mixed bed ex- change resins respectively to remove ions and to adjust the pH.
-
Structural and Functional Alterations of the Gastrointestinal Tract Following Radiation-Induced Injury in the Rhesus Monkey
The plasma supernatant was added to a column containing 2 cm of a mixed bed exchange resin (JT Baker Mixed Bed Exchange Resin IONIC NM60 Hϩ / .
Indicates content that may require registration and/or purchase.