Supplier: Accuris
Description: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method
-
Supplier: Accuris
Description: Crude petroleum and petroleum products - Determination of density - Part 1: Oscillating U-tube method
-
Supplier: Accuris
Description: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method (ISO 12185:1996)
-
-
Description: Gives a method for the determination, using an oscillation U-tube densitometer, of the density of crude petroleum and related products within the range 600 kg/m^3 to 1 100 kg/m^3 which can be handled as single-phase liquids at the test temperature and pressure.
-
Supplier: CSA Group
Description: Gives a method for the determination, using an oscillation U-tube densitometer, of the density of crude petroleum and related products within the range 600 kg/m^3 to 1 100 kg/m^3 which can be handled as single-phase liquids at the test temperature and pressure.
-
Supplier: Accuris
Description: Crude petroleum and petroleum products - Determination of density using the oscillating U-tube method (ISO 12185:1996)
-
Supplier: CSA Group
Description: ISO 18301:2014 specifies a method for the determination of the conventional mass per volume of vegetable and animal oils and fats within the range of 0,800 kg/l to 1,000 kg/l which are in a single-phase liquid state at the test temperature. This method is not intended for use in calibrating online
-
Supplier: AENOR
Description: Crude petroleum and petroleum products - Determination of density - Oscillating U-tube method (ISO 12185:1996)
-
Supplier: Anton Paar
Description: hygienic applications. Both, L-Dens 7400 and L-Dens 7500, have one-piece oscillating tubes (L-Dens 7400: U-shaped tube; L-Dens 7500: W-shaped tube). The L-Dens 7000 series uses digital signal processing and can be equipped with the new Pico 3000 transmitter and
- Pressure Range: 0 to 725.1885 psi
- Temperature Range: -40 to 125 F
- Density Range: 3,000,000 g/cm³
- Display & Special Features: Computer Interface / Networkable, In-Line, Laboratory Style (Benchtop or Handheld)
-
Supplier: AENOR
Description: Crude petroleum, petroleum products and related products - Determination of density - Laboratory density meter with an oscillating U tube sensor (ISO 12185:2024)
-
Supplier: diaago
Description: This Tube Revolver can be used in a variety of laboratory fields such as Molecular Biology, Biochemistry, Clinical, and Histochemistry. The rotisseries are interchangeable so that the unit works with a variety of tube sizes. The four rotisserie paddles can be mixed for a combination of
- Motor Speed: 10 to 40 rpm
- Mixer Type: Paddle
-
Supplier: CSA Group
Description: liquid state. Milk and milk products (or fat coming from milk and milk products) are excluded from the scope of this document. NOTE The determination of conventional mass per volume (litre weight in air) using the oscillating U-tube method can be found in ISO 18301.
-
Supplier: ASTM International
Description: first ascertained that no bubbles form in the U-shaped, oscillating tube, which can affect the density determination. Some examples of products that may be tested by this procedure include: gasoline and gasoline-oxygenate blends, diesel, jet, basestocks, waxes, and lubricating
Find Suppliers by Category Top
Featured Products Top
-
performance under oscillating movement — Thin-wall construction permits compact bearing assembly — Indents in the bearing surface provide a reservoir for grease and thus allow extended re-greasing intervals Connect with us on our (read more)
Browse Plain Bearings and Sleeve Bearings Datasheets for GGB -
Zero water absorption making them dimensionally stable Compact and light Suitable for rotating, oscillating, reciprocating and sliding movements No machining required (read more)
Browse Plain Bearings and Sleeve Bearings Datasheets for GGB -
Download Solid Models Cylindrical, Limited Rotational Bearing The versatile pivot bearing can function as a simple oscillating unit or as (read more)
Browse Pivot Bearings Datasheets for C-Flex Bearing Company -
used. Double ended bearings are also useful in forced oscillation applications where the center sleeve is used as the fixed point. Here an oscillation creating device can be mounted to one outer sleeve and the assembly to be oscillated can be attached to the other sleeve. This allows for a setup (read more)
Browse Plain Bearings and Sleeve Bearings Datasheets for C-Flex Bearing Company -
available for maximum deflection angles of +/-30, but various configurations are supplied upon request. Torsional stiffness ranges from .0003 Lb-In/degree to 7.8023 Lb-In/degree. It can be used simply as an oscillating unit or an extremely sensitive critical element. The advantages of cross (read more)
Browse Pivot Bearings Datasheets for C-Flex Bearing Company -
request. Torsional stiffness ranges from .0003 Lb-In/degree to 7.8023 Lb-In/degree. It can be used simply as an oscillating unit or an extremely sensitive critical element. The advantages of cross-flexure bearings has been well documented in connection with the replacing of ball bearing pivots (read more)
Browse Pivot Bearings Datasheets for C-Flex Bearing Company -
request. Torsional stiffness ranges from .0003 Lb-In/degree to 7.8023 Lb-In/degree. It can be used simply as an oscillating unit or an extremely sensitive critical element. The advantages of cross-flexure bearings has been well documented in connection with the replacing of ball bearing pivots (read more)
Browse Pivot Bearings Datasheets for C-Flex Bearing Company -
closure must withstand an oscillating load which comes from air turbulence and sound waves of the ignition environment. This drives the minimum strength of the nozzle plug. Key Requirements: Be able to make compound (read more)
Browse Foams and Foam Materials Datasheets for General Plastics Manufacturing Co.
More Information Top
-
ASTM MNL59 - A Comprehensive Review of Lubricant Chemistry, Technology, Selection, and Design
… T60-156 T60-159 Test Description Air Release Properties Filterability of Hydraulic Fluids Filterability of Hydraulic Fluids Cloud Point Determination Kinematic Viscosity and Calculation of Dynamic Viscosity Density by the Use of Hydrometer Density by Oscillating U Tube Method Water Content by …
-
Chapter 12: Lubricant Testing
Density by Oscillating U Tube Method NF ISO 3733 ͑T60113͒ .
-
Research Highlights: November
Data were determined in the 15–40°C range with a densitometer utilizing the oscillating U tube technique.
-
A recurring suprise.
Aspects considered include: analytical factors (e.g. refractometer calibration, differences between areometer, oscillating U tube and FTIR analysis); association between sp. gr and sugar concn. of musts; alcohol yield during fermentation; and case study on alcohol concn. in Blanc de Noir and …
-
A RAPID SMALL SCALE METHOD FOR THE DETERMINATION OF MALT EXTRACT
The refrac- tometer was trialled and accepted as a method for determin ing specific gravity5610" and the oscillating U tube density meter also showed good correlation with the standard specific gravity bottle19 procedure.
-
Heat and mass transfer characteristics of absorption of R134a into DMAC in a horizontal tube absorber
The volumetric flow rate of the poor solution is mea- sured by an ultrasonic flow meter as well as the density of the poor solution with an oscillating U tube , so that the mass flow rate can be calculated.
-
Evaluation of Correlations and Parachors To Predict Low Interfacial Tensions in Condensate Systems
Density measurementsfor the model condensate (Table 1)were taken using a rig containing an oscillating U tube densitometer.
-
Free oscillations of fluids in manometers
The first extensive investigation by Menneret (3) occurred shortly after the fundamental paper in boundary-layer theory, which it could have utilized; however, even in the late 1940's the boundary-layer character of some U tube oscillations was not well appreciated.
-
Slip in quantum fluids
The theory is also able to account for the behavior observed in U tube oscillation experiments where in addition to the slip at the surfaces of the U-tube, normal-fluid to superfluid conversion at the free surface plays a significant role …
-
Practical Handbook of Grouting: Soil Rock and Structures Complete Document
The U tube oscillates at varying frequency depending on the mass of the passing flow.
Indicates content that may require registration and/or purchase.