Supplier: Owlstone Inc.
Description: Lonestar is a portable gas analyzer that can detect a broad range of analytes at part per billion concentrations, with high selectivity in just a few seconds.
- Operating Temperature: 41 to 104 F
- Operating Humidity: 5 to 90 %
- Response Time: 1.000000000000002 seconds
- Measurement Type: %Volume, Signature or Spectra, Trace
-
Supplier: ABB Measurement & Analytics
Description: performance validation. The Analyzer has an internal computer (Linux OS) that can store data practically indefinitely on its hard disk drive and send real time data to a data logger via the digital (RS232) or Ethernet outputs. Furthermore, as with all LGR analyzers, this
- Application: Ambient Air Monitoring
- Gas Types: Ammonia (NH3)
- Instrument Type: Analyzer
- Mounting Type: Portable
-
Supplier: ABB Measurement & Analytics
Description: LGR's Greenhouse Gas Analyzer (model GGA-24EP) is the world's most advanced instrument for simultaneous measurements of methane (CH4), carbon dioxide (CO2) and water vapor (H2O). Quite simply, no other analyzer provides higher performance. (For details, please see: advantages).
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
-
Supplier: ABB Measurement & Analytics
Description: analyzers to make true measurements at data rates of 20 Hz makes them excellent choices for eddy covariance flux measurements and for mobile leak (e.g., natural gas, coal seam gas, coal bed methane) detection. The analyzer uses ABB’s patented Off-axis ICOS technology, the
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Instrument Type: Analyzer
- Gas Types: Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
- Number of Gases Monitored: Multi Gas
-
Supplier: ABB Measurement & Analytics
Description: Analyzer (and N2O/CO Analyzer) in our acclaimed portable package. Moreover, only LGR’s analyzers provide reliable measurements (guaranteed) at concentrations more than 20 times greater than typical ambient levels. Furthermore, LGR's Analyzers report
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Monoxide (CO), Water Vapor
-
Supplier: Nova Analytical Systems Inc.
Description: No Description Provided
- Measurement Type: %LEL, %Volume, Trace
- Application: Ambient Air Monitoring, Confined Space Monitoring, Personal Exposure Monitoring
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Chlorine (Cl2), Chlorine Dioxide (ClO2), Combustible Gas, Hydrocarbons, Hydrogen (H2), Hydrogen Sulfide (H2S), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Oxygen
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 310 Series Portable Flue Gas CO Analyzer utilizes a reliable, customer-replaceable electrochemical sensor which responds quickly to the CO present in the flue gas sample. Its life expectancy is between 2 and 3 years. The flue gas sample drawn into the
- Response Time: 20 seconds
- Operating Temperature: 32 to 105 F
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 313 Series Portable Flue Gas Analyzer for NO, NO2, or NOx utilizes reliable, stable NO and/or NO2 sensors which respond quickly to the NO or NO2 present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOx found in flue gases or engine exhaust
- Response Time: 20 seconds
- Operating Temperature: 55 to 120 F
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 312 Series Portable Flue Gas Analyzer for NOX utilizes a reliable, stable nitric oxide (NO) sensor which responds quickly to the NO present in flue gases or engine exhaust. NO is the major component (90-95%) of the NOX found in flue gases or engine exhaust (except
- Response Time: 20 seconds
- Operating Temperature: 55 to 120 F
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Process Sensing Technologies USA
Description: premature depletion due to exposure to ambient oxygen levels to increase their lifespan. It all adds up to economical operation and low cost of ownership for this market-leading portable oxygen analyzer range. Features: Measurement ranges from 0-10 ppm up to 0-100% O2 Accuracy
- Operating Temperature: 41 to 113 F
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer, Monitor
- Display: Digital
-
Supplier: Owlstone Inc.
Description: NEXSENSE C is a man portable chemical detection and identification system that enables rapid and robust on-scene analysis of chemical agents from airborne samples. Utilising Owlstone's cutting edge Field Asymmetric Ion Mobility Spectrometry (FAIMS) technology combined with intelligent data
- Operating Temperature: 32 to 95 F
- Response Time: 10.00000000000002 seconds
- Application: Ambient Air Monitoring
- Instrument Type: Analyzer
-
Supplier: Oneida Research Services, Inc.
Description: With the IVA® Model 210s Internal Vapor Analyzer, you can perform package moisture and gas analysis, on-site at your facility. This is a user-friendly test system for monitoring the quality of your hermetic packaging processes. IVA® Technology was invented by ORS and offers the most
- Application: Ambient Air Monitoring, Confined Space Monitoring
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Hydrogen (H2), Nitrogen Dioxide (NO2), Oxygen (O2), Water Vapor
- Features: Controller, Data Logger, Other, Self Calibration
-
Supplier: MO2 Inc.
Description: The PetroCheck Portal Hydrocarbon Analyzer (PHA) is the ideal instrument for precise measurement and quantification of petroleum hydrocarbons dissolved in water and/or as vapor. The PetroCheck PHA is designed to meet rigorous field monitoring requirements and has proven itself in industrial,
- Response Time: 4.999999999999998 seconds
- Operating Temperature: 32 to 122 F
- Application: Ambient Air Monitoring, Process Gas
- Electrical Outputs: Analog Voltage
-
Supplier: Environics, Inc.
Description: The Environics® Series 9100 Computerized Ambient Monitoring Calibration System is an advanced microprocessor controlled instrument for dynamic calibration of ambient air analyzers. Features include: Output concentrations as low as 5 ppb Ability to easily set concentration
- Output Flow Rate: 0.1000111361652 to 1,000 SLM
- Generator Type: Ozone
- Features & Approvals: Portable
- Features: Specialty / Other
-
Supplier: Honeywell Analytics, Inc.
Description: A fast response device detecting down to ppb of toxic gases, providing physical evidence of a gas event. This use-anywhere, fast response monitor is specific to your target gas only. Until now, the big concern with basic units for toxic gas monitoring was that environmental
- Operating Temperature: 32 to 104 F
- Response Time: 10.00000000000002 seconds
- Application: Ambient Air Monitoring, Process Gas
- Gas Types: Ammonia (NH3), Arsine (AsH3), Bromine (Br2), Chlorine (Cl2), Chlorine Dioxide (ClO2), Combustible Gas, Diborane (B2H6), Germane (GeH4), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen Fluoride (HF),
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: portable instruments, etc. FEATURES NDIR technology with independent intellectual property Super low power consumption to μA level High accuracy, long-term stability, long life (>15 years) Matrix calibration within whole measurement range and temperature range Small size and compact
- Operating Temperature: 14 to 122 F
- Operating Humidity: 0 to 95 %
- Number of Channels: 1
- Measurement Type: %LEL, %Volume
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: DESCRIPTION AM1008W is an ultra-thin indoor air quality sensor with highly integrated laser particle sensor, NDIR CO2 sensor, temperature sensor and humidity sensor, which can real-time output digital measurement data. The thinnest size. And the VOC sensor integrated can be customized. FEATURES
- Operating Temperature: 14 to 122 F
- Operating Humidity: 0 to 95 %
- Number of Channels: 1
- Response Time: 30 seconds
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: DESCRIPTION Infrared carbon dioxide CO2 sensor CM1106SH can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and cold
- Operating Temperature: 14 to 122 F
- Operating Humidity: 0 to 95 %
- Number of Channels: 1
- Response Time: 30 seconds
-
Supplier: Sensidyne, LP
Description: The Sensidyne Compressed Breathing Air (CBA) Analysis Kit allows anyone to simply, quickly, and quantitatively measure all four of the common contaminants in breathing air, plus oxygen defeciency.
- Number of Channels: 1
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring, Confined Space Monitoring, Continuous Emissions Monitoring, Personal Exposure Monitoring, Process Gas
- Display: Analog
Find Suppliers by Category Top
Featured Products Top
-
CO2Meter Inc., a worldwide leader in gas detection and safety monitoring, released its new portable CO2 welding gas analyzer that verifies correct CO2 concentrations in welding gas mixes. The highly anticipated CM-1650 measures mixed cylinder gas or blended gas at a mixer to ensure the (read more)
Browse Data Loggers and Data Recorders Datasheets for CO2Meter.com -
What makes the Series 6103 the multi-gas calibrator of choice for ambient monitoring? Ambient air quality data is only valuable when its measurements can be (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc. -
Aii’s portable diving mix analyzers are designed to measure oxygen concentration in diving gas mixtures, supporting safe dive planning and gas verification. Compact and easy to use, they allow divers to confirm oxygen levels before use (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
AII’s premium portable O? analyzers are engineered for applications where performance, reliability, and advanced functionality are essential. These instruments deliver accurate oxygen measurement with enhanced durability and user-focused design (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
AII premium portable oxygen analyzers deliver accurate and stable oxygen measurement in a robust, portable format. Designed for professional use, they support reliable analysis in a wide range of operating conditions (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
AII’s portable O? analyzer range provides accurate oxygen measurement in a variety of portable and field-based applications. Designed for ease of use and dependable performance, these analyzers support oxygen verification wherever mobility is required (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
. Common locations for gas detection include – (1) ambient air, (2) gas cabinets, (3) valve manifold boxes, (4) gas storage. Alternate locations include tool-specific valve boxes, hydrogen distribution boxes, vacuum pump enclosures, and abatement systems. Toxic gases (read more)
Browse Gas Instruments Datasheets for DOD Technologies Inc. -
AII’s handheld oxygen analyzers for medical gases are designed to provide fast, accurate measurement of oxygen concentration in medical environments. Portable and easy to use, these analyzers support verification of oxygen purity in medical gas pipelines (read more)
Browse Gas Sensors Datasheets for Analytical Industries Inc. -
An accurate and reliable hygrometer, easy to use for spot measurement of trace moisture in gases and compressed air. The SADP portable dewpoint meter is suitable for rapid moisture checks in a wide range of industries including power (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Shaw Moisture Meters -
. Manufactured in the UK, the SDHmini Portable Sample System (SDH-PSS) is an effective, self-contained sampling system, designed for gas or general compressed air sampling to ensure sample pressure and flow are suitable for trace (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Shaw Moisture Meters
More Information Top
-
CR4 - Thread: Portable Ambient Gas Analyzers
Portable Ambient Gas Analyzers .
-
CR4 - Thread: Spikes from Transmitter
Next in Forum: Portable Ambient Gas Analyzers .
-
CR4 - Thread: Temperature Data Logger TC-08 (USB)
Previous in Forum: Portable Ambient Gas Analyzers .
-
Photosynthetic and antioxidant responses of M exican lime ( Citrus aurantifolia ) plants to Citrus tristeza virus infection
Leaf-gas exchange parameters were measured with an LCpro+ portable infrared gas analyser (ADC Bioscientific Ltd) under ambient CO2 and humidity.
-
Spatial variation in CO2 exchange at a northern aapa mire
… was measured with a transparent plastic chamber (60 9 60 9 31 cm) equipped with a battery-operated fan, a cooling system that maintained the temperature within 2°C of the ambient temperature, and a portable infrared gas analyser (EGM-3 and EGM …
-
Comparison of Vegetation and CO 2 Dynamics Between a Restored Cut‐Away Peatland and a Pristine Fen: Evaluation of the Restoration Success
The air-sealed chamber had a battery-operated fan, a cooling system that maintained the temperature within 2◦ C of the ambient temperature, and a portable infrared gas analyzer (EGM-3, EGM-4 in the pristine site, EGM-2 in the restored …
-
Ecophysiology of photosynthesis in bryophytes: major roles for oxygen photoreduction and non‐photochemical quenching?
Measurements of the PPFD responses of CO2 exchange in ambient air were made using a portable infra- red gas analyser (IRGA) (Leaf-chamber analyser, Type LCA-2, with broad-leaf Parkinson leaf chamber, ADC, Hoddesdon, Herts, UK) in differential mode (open system …
-
Effect of enhanced atmospheric CO 2 on mycorrhizal colonization and phosphorus inflow in 10 herbaceous species of contrasting growth strategies
The ambient CO2 concen- tration was measured with a portable gas analyser (ADC Ltd, UK).
-
Hazardous chemicals detection experiment
Measurement equipment included a Bruel & Kjaer Type 1302 multi- gas monitor, Miran Foxboro 1BX portable ambient air analyzer , and Microtip photoionization detectors.
-
A Survey of U.S. Commercial Environmental and Industrial Optical Sensor Environmental Monitoring Equipment Manufacturers
Productsincludegas, stack gas and ambient air analyzers ,air qualitymonitoringdevices and portable and continuoushydrocarbonmonitors.
Indicates content that may require registration and/or purchase.