Supplier: Flow Technology, Inc.
Description: , chrome–plated stainless steel cylinder used to displace the fluid used for calibration. QUICK SPECS Ballistic Primary Standard Calibrator for Liquids Flow range of 0.001 to 400 GPM (0.004 to 1500 LPM) ± 0.05% uncertainty of volumetric flow rate measurement (95%
- Calibrator Style: Fixed
- Computer Interface: Yes
- Operating Temperature: 60 to 120 F
- Process, Environmental, Thermodynamic Properties: Flow
-
Supplier: Flow Technology, Inc.
Description: determined. To calibrate a gas flow meter using the Autobell®, the flow meter must be installed upstream of the bell so that all gas flowing through it is captured by the calibrator. QUICK SPECS Primary standard gas calibration system Flow range of
- Calibrator Style: Fixed
- Computer Interface: Yes
- Operating Temperature: 65 to 75 F
- Process, Environmental, Thermodynamic Properties: Flow
-
Supplier: Sierra Instruments, Inc.
Description: Sierra’s CalTrak™ XL primary standard gas calibration system is the leading high flow primary standard calibrator in industry and offers a standardized accuracy of +/-0.25%. With increased demand for higher flows of process gas, there is a requirement
- Application Software Included: Yes
- Calibrator Style: Fixed, Battery Powered
- Computer Interface: Yes
- Display Type: Digital Readouts
-
-
Supplier: Flow Technology, Inc.
Description: Primary Standard Liquid & Gas Flow Calibrations Fast…24-hr turnaround available Accurate…measurement uncertainty to 0.025% Accredited…ISO/IEC 17025 and ANSI Z540-1 Data Trending…customer calibration
- Capabilities: Flow Instruments
- Location: North America, United States Only, Southwest US Only
- Services: Bench (Off-site), Calibration Service, Calibration Documentation, Rapid Turnaround, Product Sales - New, Troubleshooting and Repair
-
Supplier: Eastern Instruments
Description: High Beta® can be *NIST reference calibrated prior to installation. Typical *NIST calibrated total flow uncertainties can be as low as ±0.50% over the calibrated range. SUPERIOR PLUG RESISTANCE In many cases, pitot tubes have one port facing into the air stream
- Configuration: Plate
- Media: Gas
-
Supplier: ASTM International
Description: 1.1 This test method, known as the calibrated hot box method, provides for the laboratory measurement of heat transfer through a specimen under controlled air temperature, air velocity, and radiation conditions established in a metering chamber on one side and in a climatic chamber on the
-
Supplier: Edgetech Instruments Inc.
Description: certification and ease of use. Its primary method chilled mirror sensor provides precision dew/frost point temperature measurement in a robust, transportable package. Simply attach the sample line, adjust the flow with the integral flow meter and turn on the power. Within
- Dew Point Accuracy: 0.4500 +/-F
- Dew Point Range: -103 to 122 F
- Digital Outputs: Serial Interface
- Display: Digital Readouts
-
Supplier: CSA Group
Description: high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7. ISO 5167-5:2016 also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1.
-
Description: calibrated APC; c) establishing acceptable operation and performance limits; d) verifying particle sensor performance using a truncated test dust; e) determining coincidence and flow rate limits.
-
Supplier: Environics, Inc.
Description: for collecting, integrating, and processing meteorological, air quality, and water quality data. The 6103 comes standard with two mass flow controllers, but a third can be added to support a larger range of dilutions. The mass flow controllers are calibrated to a NIST
- Features: Portable
- Generator Type: Ozone, Specialty / Other
- Output Flow Rate: 0.1000 to 1000 SLM
-
Supplier: Environics, Inc.
Description: mass flow controllers calibrated to a NIST (National Institute of Standards and Technology) traceable primary standard. The calibration data consists of a comparison of desired versus actual flow over the full dynamic range of the instrument with linear
- Features: Portable
- Generator Type: Ozone
-
Supplier: SAE International
Description: The primary objective of this document is to describe the systematic and random measurement uncertainties which may be expected when testing gas turbine engines in a range of different test facilities. The documentation covers a "traditional" method for estimating pretest uncertainties and a
-
Supplier: ASTM International
Description: these measurements requires calibration to ensure that the data are accurate. During initial setup and periodic verification testing, each measurement system and sensor is calibrated against a standard traceable to a national standards laboratory. If the hot box apparatus has
-
Supplier: ASTM International
Description: these measurements requires calibration to ensure that the data are accurate. During initial setup and periodic verification testing, each measurement system and sensor is calibrated against a standard traceable to a national standards laboratory. If the hot box apparatus has
-
Supplier: ASTM International
Description: performing these measurements requires calibration to ensure that the data are accurate. During initial setup and periodic verification testing, each measurement system and sensor is calibrated against a standard traceable to a national standards laboratory. If the hot box
-
Supplier: CSA Group
Description: suspensions verified with a primary calibrated APC; c) establishing acceptable operation and performance limits; d) verifying particle sensor performance using a truncated test dust; e) determining coincidence and flow rate limits.
-
Supplier: Badger Meter
Description: -contained unit that enables automobile manufacturers to test their vehicle designs in accordance with recognized industry standards. High Performance Accuracy. Calibrated against a primary standard air flow calibrator to ensure a consistent, high accuracy
- Operating Temperature: 40 to 120 F
-
Supplier: Environics, Inc.
Description: are factory calibrated using a primary flow standard traceable to the United State's National Institute of Standards and Technology (NIST). Each flow controller utilizes an 11 point calibration table with linear interpolation, to increase accuracy and reduce
-
Supplier: Environics, Inc.
Description: application that communicates with the Environics system via a USB (standard) or RS232 serial interface. The Series 4000 consists of a single chassis now supporting up to eight mass flow controllers. The mass flow controllers are factory calibrated using a primary
- Accuracy: 1 ±% FS
- Control Signal Output: Serial / Digital
- Control Technique: Limit / Set Point Control
- Controller Inputs: Serial / Digital Input
-
Supplier: Fieldbus International AS
Description: the HART 6.0 standard. T280 is suited for a two-wire loop powered design. T280 supports HART multidrop configuration. T280 supports HART burst mode communication. General description: T280 contains a four channel 24 bit A/D converter from Texas Instruments. The circuit board comprises a
-
Supplier: ValueTronics International, Inc.
Description: may break down and result in current flow leakage. HiPot testers keep engineers safe from current leakages by detecting gaps and defects in the electronic device. Dielectric Testers, Insulation Testers, and Megohmmeters are similar to HiPot testers. Popular manufacturers include Biddle,
-
Supplier: Eaton Cooper Power Systems
Description: distribution cutouts that uses a fiber tube and fuse link design, and considerably reduces the hazards and noise of the violent exhaust common to cutouts under fault interrupting conditions. The CMU Power Fuse, employing the use of calibrated silver element, boric acid for its interrupting
- Current Rating: 200 amps
- Voltage Rating: 38000 volts
-
Supplier: AMETEK Programmable Power
Description: approximately 1.5 Ohms at 30kW continuous and 60kW peak. Energy Absorber Control Chassis The Energy Absorber Control chassis contains primary and secondary voltage clamps consisting of an IGBT and an SCR. In addition, it contains a GPIB programmer and measurement circuitry and controls that
- Options / Module Types: Measure Unit / Monitor
- Type / Form Factor: Test Platform / System
Find Suppliers by Category Top
Featured Products Top
-
ambient monitoring, where target concentrations are often near detection limits, even small flow errors can translate directly into measurement uncertainty. The Series 6103 addresses the sensitivity of low-level concentration accuracy to small flow deviations with mass flow controllers calibrated at (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc. -
van. Repeatability: CEM calibration systems have a repeatability of ±0.05% of full scale. Accuracy: They use NIST-traceable calibrated precise thermal mass flow controllers, with the most accurate (read more)
Browse Manifolds and Manifold Systems Datasheets for Environics, Inc. -
calibrations. The 6123 is a type of photometer that meets all requirements set out by the U.S Environmental Protection Agency for a level 3 transfer standard. Its included mass flow controller is calibrated to the NIST (National Institute of Standards and Technology) traceable primary (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc. -
Photometric Procedure for Ozone Transfer Standards The photometric procedure for ozone transfer standards has several benefits, from high precision to low costs, and others such as: Accuracy: Using a calibrated photometer and mass flow controller ensures accurate ozone (read more)
Browse Datasheets for Environics, Inc. -
How Mass Flow Controllers Enable Accurate Calibration Standards Calibration is a critical, yet often overlooked aspect of benchtop chromatography. Guidance on (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
unparalleled customer satisfaction while continually advancing the technology of liquid pressure and flow control. As the quality leader in the development of thermoplastic valves and controls for corrosive and ultra-pure liquids, POM provides a complete line of standard and custom designed solutions (read more)
Browse Sight Flow Indicators Datasheets for Plast-O-Matic Valves, Inc. -
. Digital and analog output options The DigitalFlow GM868 flowmeter makes it easy to send the data where it needs to go, through the standard digital output, standard or optional analog outputs or optional alarms. All outputs are conveniently set up and (read more)
Browse Flow Meters Datasheets for Panametrics -
Marposs Leak and Flow Testing Solutions – the smart choice for manufacturers who demand speed, accuracy, and reliability. Designed to guarantee compliance with quality standards in R&D, production, and Quality Control processes, Marposs (read more)
Browse Leak Testing Equipment Datasheets for Marposs Corp -
.20% of range. The Multi-Mag's highly stable flow sensor comes pre-calibrated from the factory and requires virtually no recalibration. With no moving parts, the Multi-Mag's multi-electrode sensor contains nothing to wear or break, and it is generally immune to clogging by sand, grit or other (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
tubing Made from non-toxic ingredients conforming to FDA standards Kink and crush resistant Handles pressure and full vacuum (29.9 in.Hg.) applications Glass-like clarity with mirror-smooth surfaces provide outstanding visual flow characteristics (read more)
Browse Tubing Datasheets for NewAge Performance Products | NAPP
More Information Top
-
Sierra Instruments Introduces New Primary Standard Gas Flow Calibrator For High Flows Up To 500 Slpm
Sierra Instruments Introduces New Primary Standard Gas Flow Calibrator For High Flows Up To 500 Slpm .
-
10.8.08 -- Liquid Handling Products To Be Showcased At Neuroscience 2008
Sierra Instruments Introduces New Primary Standard Gas Flow Calibrator For High Flows Up To 500 Slpm .
-
https://uwspace.uwaterloo.ca/bitstream/handle/10012/1285/y9chen2004.pdf?sequence=1
The actual airflow rate was verified by use of a primary gas flow standard Mimi-Buck calibrator (A.P. Buck, Orlando, FL, USA).
-
Real-time and Retrospective Analysis of U.S. Navy Submarine Atmospheres
The pumps were periodically calibrated using a similarly packed Tenax tube and a Bios International Model DC-ISC gas flow calibrator (traceable to a NIST primary standard ).
-
Diffusive Sampling of US Navy Submarine Atmospheres
The pumps were periodically calibrated using a similarly packed Tenax tube and a Bios International Model DC-ISC gas flow calibrator (traceable to a NIST primary standard ).
-
Flow Transfer Standards: Versatile, Cost-Effective Solutions for In-House Flowmeter Calibrations (.pdf)
The most common examples of primary standard calibrators include positive displacement, continuous flow loop, and time-weigh systems.
-
Control Engineering Europe Evaluates Latest FTI Calibration Solution
The most common examples of primary standard calibrators include positive displacement, continuous flow loop, and time-weigh systems.
-
Particle Size Distribution of Single and Multiple Sprays of Salbutamol Metered-Dose Inhalers (MDIs)
A vacuum pump (GAST, General Electric Corporation, Model 0522-V48- G180DX) was used to draw the air flow through the impac- tor, air flow was measured with a Primary Standard Airflow Calibrator (Gilian Gilibrator).
-
Characterization of rocket propellant combustion products: Description of sampling and analysis methods for rocket exhaust characterization studies
Flow rates through the Draeger tubes were carefully chect:ed prior to each test run using a volumetric standard (Buck model M-5 primary gas flow calibrator , A.P. Buck Inc., Orlando, FL.) .
-
Personal and indoor exposure to PM2.5 and polycyclic aromatic hydrocarbons in the southern highlands of Tanzania: a pilot-scale study
Trical volumetric air flow calibrator ), calibrated against a bubble flow meter primary standard (Sensidyne Gilian Gilibrator), was used to measure flow rates.
Indicates content that may require registration and/or purchase.