Supplier: Aggreko
Description: 1,200,000 BTU Hydronic Heater From small-scale projects to demanding heating requirements, Aggreko is the solution for all of your needs involving portable, industrial heaters. Features Conversion from one fuel source to another can be accomplished in as little as 15 mins. Temperature
- Heating Capacity: 361.3923 kW
- AC Voltage Required: 115 to 230 volts
- Heater Type: Air Heater
- Features: Electric, Natural Gas / Propane, Other
-
Supplier: Reznor
Description: board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in heating control functions. Optional features include three newly designed, factory assembled, modular sections- a draw-through cooling coil cabinet module with either
- Heating Capacity: 102.5 kW
- AC Voltage Required: 115 to 575 volts
- Maximum Air Flow: 6,563 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
-
Supplier: Reznor
Description: average cooling supply air temperature of 50° to 55°F off the main coil in humid to temperate climates. The RDDB utilizes environmentally-friendly R-410A refrigerant in all circuits for higher efficiency, and to be covered under changing regulations. Model RDDB units also include Reznor
- Heating Capacity: 117.24 to 205.17 kW
- AC Voltage Required: 208 to 575 volts
- Maximum Air Flow: 9,000 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
-
-
Supplier: Thermal Fluid Systems, Inc.
Description: Thermal Fluid Systems, Inc. is proud to offer the custom design and supply of high efficiency thermal fluid (sometimes called hot oil or Dowtherm) heaters and systems. The heaters and systems can be: Gas Fired Oil Fired Waste Fuel Fired We build our thermal fluid heaters
- Maximum Operating (Sheath) Temperature: 750 F
- kWatts: 0.00014655 to 14,655 kW
- Maximum Operating Temperature: 750 F
- Heating Capacity: 0.00014655 to 14,655 kW
-
Supplier: Peerless Boilers
Description: the expense of a separate water heater. The built-in tankless heater is capable of producing up to 4 gallons of domestic hot water per minute. The tankless heater can be removed from the boiler unit for hassle-free cleaning. read more
- Heat Output (Capacity): 27,000 BTU/hr
- Fuel Type / Heat Source: Gas (Natural / Propane)
- Type: Hot Water
-
Supplier: Crown Boiler Co.
Description: to 2,850,000 BTU/hr. This boiler has built-in draft hoods for installation under low ceilings, and a choice of control options make the Series 32 the best choice for a wide variety of commercial applications. Domestic hot water can be provided by an optional tankless coil water heater
- Efficiency: 80.5 %
- Technology: Cast Iron
- Fuel Type / Heat Source: Gas (Natural / Propane)
- Type: Hot Water, Steam
Find Suppliers by Category Top
More Information Top
-
Experimental determination of the energy of a gas vortex motion during autooscillations in a free convective flow
At one-quarter of the sleeve length from its lower edge was a heat source represent- ing either a diffuse propane torch or an electrical heater coil .
-
Shutdown plan for the 300 area fuel supply facilities
storage area. conference rooms, and one change room. roof-mounted air handlers. evaporative coils have been turned off. wall-mounted propane heaters .
-
Reaching for Peak Performance in Existing Homes -- A Cold Climate Study With Synergy Construction
A propane -fired on-demand water heater provides hot water to a hot water coil in the air handlers to provide heating in conditions where the ASHP system would not have adequate capacity to meet the heating load.
-
Petrochemical
Ethylene and co-products are produced from steam cracking of hydrocarbons such as ethane, propane , butane, naphtha, and gas oil in tubular reactor coils installed in externally fired heaters .
-
Evaluation of the Field Performance of Residential Fuel Cells: Final Report
This includes a 75-gal Bradford White CombiCor natural gas or propane water heater that incorporates an internal, double-wall, air-gap thermal recovery coil ; plastic pipe power venting without a chimney; circulating pump and temperature controller; and all related hardware with …
-
CR4 - Thread: Vintage Natural Gas "Sands" Water Heater, Help Please
We are NOT going to replace the missing water heating coil , it is to be used as a jobsite outdoor heater only, hopefully on regular bottled propane .
-
Residential Fuel Cell Demonstration Handbook: National Rural Electric Cooperative Association Cooperative Research Network
This can be by substitution of a natural gas / propane furnace for the heat pump air handler or, alternately, by the replacement of the supplemental heaters with an hydronic coil connected to the converted, thermal recovery water heater.
-
Performance Improvement of Direct- and Indirect-Fired Heaters
In indirect-fired heaters , such as propane vaporizers, the bath serves as the heat-transfer medium between the fire tube and the process coil .
-
Countries > Canada > Province of Nova Scotia > Regulations > Technical Safety Act > [CANADA NS Reg 2011-10] Regulation 10/2011 - Boiler and Pressure Equipment ...
(m) a domestic hot water heater that has a diameter of 762 mm (30 in.) or less and is oil, propane or natural gas fired or uses electrical elements, spargers, jackets or coils as a heat source; .
-
Solar Energy: Technologies and Project Delivery for Buildings
Where ηheater is the efficiency of the heater and may be 1.0 for electric resistance baseboard or fan- coil unit but may be more than 1.0 … … less than 1.0 for a natural gas, propane , oil, or solid-fuel …