Supplier: Micromeritics
Description: he AccuPyc II 1340 Series Pycnometers are fast, fully automatic pycnometers that provide high-speed, high-precision volume measurements and density calculations on a wide variety of powders, solids, and slurrie shaving volumes from 0.01 to 350 cm3. The instrument
- Display & Special Features: Laboratory Style (Benchtop or Handheld)
- Media Type: Liquid, Solid
- Specimen Cell Volume Range: 1 to 350 cc
- Technology Type: Digital Instrument
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of pitch density by helium pycnometer. It is applicable at a range of room temperatures of 15 to 35°C. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of pitch density by helium pycnometer. It is applicable at a range of room temperatures of 15 to 35°C. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1
-
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of the relative density and density of semi-solid bituminous materials, asphalt, and soft tar pitches by use of a pycnometer. Note 1: An alternate method for determining the density of semi-solid and solid bituminous materials
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of density and relative density by pycnometer, and can be used for pitch that can be handled in fragments. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this
-
Supplier: Micromeritics
Description: measurements from each consolidation and automatically calculates volume and density, and reports the results in cm3 and g/cm3. The GeoPyc T.A.P. density option obtains precise results comparable to conventional tap density analyzers, only it does it faster, quieter, and
- Display & Special Features: Laboratory Style (Benchtop or Handheld)
- Instrument Type: Density Instruments
- Media Type: Solid
- Technology Type: Digital Instrument, Other
Find Suppliers by Category Top
More Information Top
-
Determination of bulk density, methods and impacts, with a case study from Los Bronces Mine, Chile†
8 Relative percentage difference plot of Archimedes versus core pycnometer density measurements .
-
Materials Handbook
ρpyc/kg.m –3 ) The pycnometer density measures the true skeletal density including closed internal porosity.
-
An Innovative Multiphase Sampling Solution at the Well Site to Improve Multiphase Flow Measurements and Phase Behavior Characterization
Without going into too many details, the first comparison of the various samples was performed via some basic measurements on the samples: shrinkage, flash GOR and pycnometer density on the condensate samples as well as pycnometer density measurement on gas samples.
-
Emerging Technologies in Hazardous Waste Management 8
Grab samples were small (approximately 3-log)specimens of the output product taken for pycnometer density measurement .
-
Irradiation test of candidate HTGR recycle fuels in the H-1 and H-2 capsules
Calculated from carbon content and 250-psi mercury pycnometer density measurements .
-
New quantitative "reading" of dielectric spectra of complex biological systems
Then the Landau and Lifshitz, Looyenga equation was used to adjust the permittivity value from the dielectric spectroscopy probe measurements to that for the body den- sity of the live insects, which was determined by the pycnometer density measurements .
-
Suitability of PEG/PMMA-based metal injection moulding feedstock: an experimental study
The standard var- iation of pycnometer density measured in five random sam- ples was very small, and thence, both feedstocks exhibited excellent homogeneity.
-
Optimisation of eco-friendly binary binder system for powder injection moulding
Homogeneity was determined by pycnometer density measurements (five samples were tested for each feedstock).
-
Microstructure, strength and CO2 separation characteristics of α-alumina supported γ-alumina thin film membrane
The sample density obtained from pycnometer density measurement and theoretical density of c-alumina, 3410 kg m23 ,2 was used for the porosity calculation.
-
CERAMIC ABSTRACTS
The X-ray method is reliable as well as speedier and simpler than pycnometer density measurements .