Supplier: Clark Solutions
Description: coupled to the float and thus, following the float position, indicates the flow rate on a scale. This indicator assembly is equipped with a scale calibrated to the operating conditions in the system and additionally may contain alarm contacts and analog output including
- Liquid Volumetric Flow Rate: 1.00E-3 to 440 GPM
- End Fittings: Threaded
- Features: Recorder / Totalizer Functions
- Media Temperature: -292 to 752 F
-
Supplier: ERDCO Engineering Corporation
Description: Here is a combination of signal transmission with independent mechanical local flow rate indication. Should your 24vdc loop go down, you will still be able to take flow rate readings at the meter.
- Gas Volumetric Flow Rate: 2 to 2000 SCFM
- Electrical Output: Analog Current, Frequency
- Media Temperature: -10 to 400 F
- Mounting Type: Insertion Type
-
Supplier: Brooks Instrument
Description: Engineered to work where you need it: Choose the MT3809 variable area (VA) flow meter (rotameter) for all the high-pressure, high-temperature VA flow measurement and control requirements on your next project. Proven to deliver reliable, repeatable gas and liquid flow measurement and
- Gas Volumetric Flow Rate: 750 SCFM
- Liquid Volumetric Flow Rate: 440 GPM
- End Fittings: Flanged, Threaded
- Features: Audible or Visual Alarms, Recorder / Totalizer Functions
-
-
Supplier: Clark Solutions
Description: , optional alarm contacts or an analog output transducer may be added. All flow meters have a male thread on the measuring tube and are supplied with two schedule 80 PVC-U pipe couplings. Please call for coupling materials other than PVC . The variety of materials used and the
- Gas Volumetric Flow Rate: 0.0024 to 4.71 SCFM
- Liquid Volumetric Flow Rate: 0.0132 to 220 GPM
- End Fittings: Threaded
- Media Temperature: 140 F
-
Supplier: Clark Solutions
Description: float position, indicates the flow rate on a scale. This indicator assembly is equipped with a scale calibrated to the operating conditions in the system and additionally may contain alarm contacts or an analog output. Model DS20 is used for measuring and monitoring the flow of
- Gas Volumetric Flow Rate: 0.0024 to 4.71 SCFM
- Liquid Volumetric Flow Rate: 4.40E-4 to 1.1 GPM
- End Fittings: Threaded
- Media Temperature: 392 F
-
Supplier: ERDCO Engineering Corporation
Description: Transmit a signal or actuate limit switches in hazardous areas with the 3700 Series Armor-Flo? meter. The cover housing is listed by Underwriters Laboratories as an enclosure for metering equipment in hazardous areas. It contains an easy to read calibrated scale and the signal output
- Gas Volumetric Flow Rate: 2 to 2000 SCFM
- Electrical Output: Analog Current, Switch
- Media Temperature: -10 to 400 F
- Mounting Type: Insertion Type
-
Supplier: OMEGA Engineering, Inc.
Description: display is supplied with a field selectable analog 0 to 5 Vdc or 4 to 20 mA output for remote monitoring; the FMA1800 series has both an integral 31.2 digit display and analog output. The display is tiltable over 90 degrees for viewing convenience. The display is
- Gas Volumetric Flow Rate: 0.0 to 35.31 SCFM
- Electrical Output: Analog Current, Frequency
- End Fittings: Compression
- Media Temperature Range: 122 F
-
Supplier: Nova Analytical Systems Inc.
Description: sample pump draws in samples that are of insufficient pressure from the process. The sample flow is shown on a small rotameter with valve. The sampling pump can be switched off when sampling gases under pressure. The analyzer then reads the dew point continuously and displays it on a
- Dew Point Accuracy: 1 +/-F
- Dew Point Range: -148 to 68 F
- Display: Digital Readouts
- Electrical Outputs: Analog Current
-
Supplier: Bronkhorst USA
Description: navigation button mounted on the front plate. An analog output signal enables data logging against various parameters and full accountability of gas flow, such as for shared ring main applications. Features: Clear indication in: - actual flow rate (bar graph and value
- Gas Volumetric Flow Rate: 0.0353 to 17.66 SCFM
- Mass Flow Rate: 0.0028 to 1.38 lbs/min
- Electrical Output: Analog Voltage
- End Fittings: Compression, Threaded
-
Supplier: Bronkhorst USA
Description: navigation button mounted on the front plate. An analog output signal enables data logging against various parameters and full accountability of gas flow, such as for shared ring main applications. Features: Clear indication in: - actual flow rate (bar graph and value
- Gas Volumetric Flow Rate: 0.0141 to 7.06 SCFM
- Mass Flow Rate: 0.0011 to 0.5506 lbs/min
- Electrical Output: Analog Voltage
- End Fittings: Compression, Threaded
-
Supplier: Bronkhorst USA
Description: navigation button mounted on the front plate. An analog output signal enables data logging against various parameters and full accountability of gas flow, such as for shared ring main applications. Features: Clear indication in: - actual flow rate (bar graph and value
- Gas Volumetric Flow Rate: 0.0353 to 17.66 SCFM
- Mass Flow Rate: 0.0028 to 1.38 lbs/min
- Electrical Output: Analog Voltage
- End Fittings: Compression, Threaded
-
Supplier: Bronkhorst USA
Description: navigation button mounted on the front plate. An analog output signal enables data logging against various parameters and full accountability of gas flow, such as for shared ring main applications. Features: Clear indication in: - actual flow rate (bar graph and value
- Gas Volumetric Flow Rate: 3.53E-4 to 0.0071 SCFM
- Mass Flow Rate Range: 5.51E-4 to 0.0028 lbs/min
- Electrical Output: Analog Voltage
- End Fittings: Compression, Threaded
-
Supplier: Orange Research, Inc.
Description: Variable-Area Flowmeters Our flowmeters are designed for those applications where a rotameter is not appropriate. Consider the inherent problems of rotameters--they are difficult to read, especially with dirty or opaque fluids, have low pressure ratings and allow vertical
- Accuracy: 2 ±%
- Approvals: CSA Mark, Other
- Display: Analog Display
- Electrical Output: Switch
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Suitable for Viscous Liquids Maintains Precision with Viscosity Change Five Material Combinations Available Economically Priced Easy to Maintain Optional Analog Output, Digital Indicating Output Options
- Electrical Output: Frequency
- End Fittings: Threaded
- Media Temperature Range: 176 F
- Operating Pressure: 580 psi
Find Suppliers by Category Top
Featured Products Top
-
Compact Analog Output (4-20mA only (read more)
Browse Linear Position Sensors Datasheets for Exsenco, LLC -
You can get a voltage or current analog signal proportional to magnet position only by applying a 24VDC power supply directly to GYcAT. It has alarm output and is equipped with noise cancellation functions. By the option, it is available with the high speed sampling, SRT, and high temperature (rod parts only). (read more)
Browse Signal Conditioners Datasheets for Exsenco, LLC -
ODOT CT-4158: High-Precision 8-Channel Analog Voltage Output Module Core Features & Benefits High-Resolution 16-Bit Performance: Equipped with a premium 16-bit Digital-to-Analog Converter (DAC) for each channel (read more)
Browse I/O Modules and Instruments Datasheets for Sichuan Odot Automation System Co., Ltd. -
Fargo Controls Inc.'s analog output inductive proximity sensors give a 0-10Vdc and/or a 4-20mA output based upon the distance between a metal target and the sensor. They do this with extended operating distances and are (read more)
Browse Inductive Proximity Sensors Datasheets for Fargo Controls, Inc. -
GYMA has the same appearance as GYMS (compact head) and is all-in-one series. We achieved downsizing of all-in-one series by the latest circuit design. GYMA has high reliability with IP67 like GYMS. Only 4-20mA output is available. (read more)
Browse Programmable Logic Controllers (PLC) Datasheets for Exsenco, LLC -
precision of 1 % over the whole temperature range from 0…70° C, 5V supply, ratiometric output signal of 0.5…4.5 VDC, and digital I2C interface make many applications possible where measurements of dry, non-corrosive gases and fluids are to be made. The PHPSU-3500 can be (read more)
Browse Pressure Sensors Datasheets for Angst+Pfister Sensors and Power -
increased 80mA discharge sinking current at 5V allows users to utilize this output as a driver for various applications, eliminating the need for additional output drivers or buffer circuitry. With a wide operating supply voltage range of 2V to 10V, the timer seamlessly integrates into various voltage (read more)
Browse IC Timers Datasheets for Advanced Linear Devices, Inc. -
This sensor use Multi-Element receiver Array to measure the target distance ranged from 20mm-100mm, with accuracy of +/-1mm(DSA-D50). Compared with the popular Sharp analog distance sensor, this sensor has an I2C digital output that is linearly proportional to the target distance and can be read (read more)
Browse Photoelectric Sensors Datasheets for Intellisense Microelectronics Ltd. -
a wide range of ports, connectors, and analog electrical outputs for ease of integration in various industrial applications. Applications: Hydraulics and Pneumatics; Mobile Hydraulics and Off-Highway Vehicles; Pumps and Compressors; Air Conditioning and Refrigeration (read more)
Browse Pressure Sensors Datasheets for Sensata Technologies -
The LUCI-M couples directly to the D-Sub interface of many FEMTO amplifiers and photoreceivers. It has a variety of input and output ports so it can be used with lots of other Analog to Digital (read more)
Browse Signal Converters Datasheets for Electro Optical Components, Inc.
More Information Top
-
Air Quality and Emission Measurement Methodology at Swine Finishing Buildings
… manifold Machine shop constructed, 3.8 cm × 46 cm 16 3,000 Mixing manifold Machine shop constructed, 3.8 cm × 31 cm 16 2,000 Flow rotameter Dwyer Model VFA-24 … … 5,200 Temperature sensors Analog Devices No. SNSR-AD592 … … input CIO-DAS-TEMP 4 3,200 Relay interface board SSR-RACK24 6 1,000 3-32 VDC input relays SSR-IDC-05 20 200 0-60 VDC output relays SSR-ODC-05 … … less than 60 s with insignificant losses in accuracy …
-
Development and testing of industrial scale, coal fired combustion system, Phase 3. Third quarterly technical progress report, July 1, 1992--September 30, 1992
The three new combustor cooling water flow sensors, whose outputs were logged by the computer, appear to have operated properly in test DP2, yielding flows that were in global agreement with flows previously measured by rotameters and dial gauges. … test priorities, the individual sensor flows were not systematically verified against the corresponding analog device during DP2.
-
In vitro assessment of infant pulmonary function equipment
The resistance of the PNT was assessed bidirectionally using known flows of air from the calibrated rotameters and measuring the pressure drop across the apparatus with a Validyne MP45 2 50 cm H,O pressure trans- ducer. The output of the transducer was digitized at 200 Hz, using an Analog Devices A-D converter, and data was collected on an I[BMcompatible 386 personal com- puter using RASP software (Respiratory Analysis Pro- gram, Physio Logic, Newbury, England).
-
Measurement of Endogenous Nitric Oxide Production
An Ohmeda TVX volume sensor clip was placed on the rotameter in the expiratory limb of the … Analog signals of the end tidal CO2 and £ow waveforms were passed through a self-designed signal noise … … recorded on 2-channel strip chart recorders (Kipp & Zonen, Bohemia, New York, U.S.A.) along with the output of the NO chemiluminescent …
-
The development of small solar concentrating systems with heat storage for rural food preparation
A rotameter (variable area £ow meter) is installed in line with the £ow meter to check the calibration of the electrical £ow meter. The output digital and analog signals of the DACS can be controlled by the personal computer.
-
Controllers implementation based on softcomputing for non-linear process
… up for this system consists of a spherical tank , a water reservoir, pump, rotameter , a differential pressure … The differential pressure transmitter output is interfaced with computer using ADAM’s 5000 Advantech module in the RS- 232 port of the PC. This module supports 8 analog input and 4 analog output channels with the voltage range of ±10 …
-
Minimum spouting velocity of dense particles in shallow spouted beds
The MFC was controlled by the National Instrument (NI) computer via analog output ports on the NI PXI 6052E data acquisition card driven by NI computer. One part of the air passed through a rotameter (used for controlling the flow split) and a humidifier before recom- bining with the remaining part of air and flowing on to the spouted bed inlet.
-
Measurement of dynamic gas disengagement profile by using an analog output level gauge
The analog output gauge is connected to a data acquisition board which in turn is calibrated to record the gas liquid dispersion height in feet units. … by filling the column up to a certain level (above 1 m height) with liquid and recording … Air was introduced through a rotameter , and a gas distributor into the column.
-
Dynamics of heat transfer to cold eggs in incubating bantam hens and a black grouse
Water flow trough the eggs was kept constant with a rotameter and measured with a measuring cylinder over three f-min periods. The thermocouple amplifiers, thermopile and electri- cal output from the O2 analyser were connected to an analog to digital converter (A/D) connected to a computer .
-
Air Quality Monitoring and On-Site Computer System for Livestock and Poultry Environment Studies
These include gas tubes, regular rotameters , handheld anemometers, psychrometers, and certain gas monitors (e.g., electrochemical gas … Type 1 and Type 2 devices are readily connectable to an on-site computer, as are Type 3 devices with analog outputs .