Supplier: Clark Solutions
Description: coupled to the float and thus, following the float position, indicates the flow rate on a scale. This indicator assembly is equipped with a scale calibrated to the operating conditions in the system and additionally may contain alarm contacts and analog output including
- Media Temperature Range: -292 to 752 F
- Liquid Volumetric Flow Rate: 0.001 to 440 GPM
- Operating Pressure: 4,641.2064 psi
- Operating Temperature: 752 F
-
Supplier: ERDCO Engineering Corporation
Description: Here is a combination of signal transmission with independent mechanical local flow rate indication. Should your 24vdc loop go down, you will still be able to take flow rate readings at the meter.
- Pipe Diameter: 0.5 to 12 inch
- Gas Volumetric Flow Rate: 2 to 2,000 SCFM
- Operating Pressure: 200 to 1,000 psi
- Media Temperature: -10 to 400 F
-
Supplier: ERDCO Engineering Corporation
Description: Transmit a signal or actuate limit switches in hazardous areas with the 3700 Series Armor-Flo™ meter. The cover housing is listed by Underwriters Laboratories as an enclosure for metering equipment in hazardous areas. It contains an easy to read calibrated scale and the signal output
- Pipe Diameter: 0.5 to 12 inch
- Gas Volumetric Flow Rate: 2 to 2,000 SCFM
- Operating Pressure: 200 to 400 psi
- Media Temperature: -10 to 400 F
-
-
Supplier: Clark Solutions
Description: position, indicates the flow rate on a scale. This indicator assembly is equipped with a scale calibrated to the operating conditions in the system and additionally may contain alarm contacts or an analog output. Model DS20 is used for measuring and monitoring the flow of low
- Gas Volumetric Flow Rate: 0.00235404896421846 to 4.70809792843691 SCFM
- Operating Temperature: -80 to 200 F
- Operating Pressure: 40 to 160 psi
- Media Temperature: 392 F
-
Supplier: Brooks Instrument
Description: blends with the needs of EPC system integrators No power required – reduces usage cost and installation complexity A reliable flow measurement technology that can communicate to control systems over analog or digital interfaces even when power is not available Broad pressure and
- Gas Volumetric Flow Rate: 750 SCFM
- Operating Temperature: -58 to 400 F
- Operating Pressure: 6,000 psi
- Media Temperature: -325 to 788 F
-
Supplier: OMEGA Engineering, Inc.
Description: display is supplied with a field selectable analog 0 to 5 Vdc or 4 to 20 mA output for remote monitoring; the FMA1800 series has both an integral 31.2 digit display and analog output. The display is tiltable over 90 degrees for viewing convenience. The display is
- Pipe Diameter: 0.25 to 0.75 inch
- Gas Volumetric Flow Rate: 0 to 35.3107344632768 SCFM
- Operating Temperature: 249.8 F
- Operating Pressure: 500 psi
-
Supplier: Clark Solutions
Description: alarm contacts or an analog output transducer may be added. All flow meters have a male thread on the measuring tube and are supplied with two schedule 80 PVC-U pipe couplings. Please call for coupling materials other than PVC . The variety of materials used and the simple to
- Gas Volumetric Flow Rate: 0.00235404896421846 to 4.70809792843691 SCFM
- Operating Temperature: 32 to 131 F
- Operating Pressure: 145.0377 psi
- Media Temperature: 140 F
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Suitable for Viscous Liquids Maintains Precision with Viscosity Change Five Material Combinations Available Economically Priced Easy to Maintain Optional Analog Output, Digital Indicating Output Options KOBOLD OVZ flowmeters offer users the advantages of
- Media Temperature Range: 176 F
- Operating Pressure: 580 psi
- Electrical Output: Frequency
- Features: Liquid, Positive Displacement
-
Supplier: Orange Research, Inc.
Description: Variable-Area Flowmeters Our flowmeters are designed for those applications where a rotameter is not appropriate. Consider the inherent problems of rotameters--they are difficult to read, especially with dirty or opaque fluids, have low pressure ratings and allow vertical
- Media Temperature Range: 200 F
- Liquid Volumetric Flow Rate: 0 to 25 GPM
- Operating Pressure: 1,500 psi
- Operating Temperature: 32 to 200 F
-
Supplier: Nova Analytical Systems Inc.
Description: sample pump draws in samples that are of insufficient pressure from the process. The sample flow is shown on a small rotameter with valve. The sampling pump can be switched off when sampling gases under pressure. The analyzer then reads the dew point continuously and displays it on a
- Dew Point Range: -148 to 68 F
- Dew Point Accuracy: 1 F
- Operating Temperature: -4 to 120 F
- Electrical Outputs: Analog Current
-
Supplier: Bronkhorst USA
Description: visible from all angles, as well as indicating flow units, gas type and totalised figures. Also available with an optional in-built needle valve for flow control duties, it is designed to mimic the straightforward features and vertical format of the VA meter, but with the considerable
- Gas Volumetric Flow Rate: 0.0353107344632768 to 17.6553672316384 SCFM
- Mass Flow Rate: 0.002753 to 1.3765 lbs/min
- Operating Temperature: 32 to 122 F
- Operating Pressure: 0 to 145.0377 psi
Find Suppliers by Category Top
Featured Products Top
-
Compact Analog Output (4-20mA only (read more)
Browse Linear Position Sensors Datasheets for Exsenco, LLC -
You can get a voltage or current analog signal proportional to magnet position only by applying a 24VDC power supply directly to GYcAT. It has alarm output and is equipped with noise cancellation functions. By the option, it is available with the high speed sampling, SRT, and high temperature (rod parts only). (read more)
Browse Signal Conditioners Datasheets for Exsenco, LLC -
Fargo Controls Inc.'s analog output inductive proximity sensors give a 0-10Vdc and/or a 4-20mA output based upon the distance between a metal target and the sensor. They do this with extended operating distances and are (read more)
Browse Inductive Proximity Sensors Datasheets for Fargo Controls, Inc. -
GYMA has the same appearance as GYMS (compact head) and is all-in-one series. We achieved downsizing of all-in-one series by the latest circuit design. GYMA has high reliability with IP67 like GYMS. Only 4-20mA output is available. (read more)
Browse Programmable Logic Controllers (PLC) Datasheets for Exsenco, LLC -
precision of 1 % over the whole temperature range from 0…70° C, 5V supply, ratiometric output signal of 0.5…4.5 VDC, and digital I2C interface make many applications possible where measurements of dry, non-corrosive gases and fluids are to be made. The PHPSU-3500 can be (read more)
Browse Pressure Sensors Datasheets for Angst+Pfister Sensors and Power -
increased 80mA discharge sinking current at 5V allows users to utilize this output as a driver for various applications, eliminating the need for additional output drivers or buffer circuitry. With a wide operating supply voltage range of 2V to 10V, the timer seamlessly integrates into various voltage (read more)
Browse IC Timers Datasheets for Advanced Linear Devices, Inc. -
a wide range of ports, connectors, and analog electrical outputs for ease of integration in various industrial applications. Applications: Hydraulics and Pneumatics; Mobile Hydraulics and Off-Highway Vehicles; Pumps and Compressors; Air Conditioning and Refrigeration (read more)
Browse Pressure Sensors Datasheets for Sensata Technologies -
The LUCI-M couples directly to the D-Sub interface of many FEMTO amplifiers and photoreceivers. It has a variety of input and output ports so it can be used with lots of other Analog to Digital (read more)
Browse Signal Converters Datasheets for Electro Optical Components, Inc. -
The ADF4377 is a high performance, ultralow jitter, dual output integer-N phased locked loop (PLL) with an integrated voltage controlled oscillator (VCO) ideally suited for data converter and mixed signal front end (MxFE) clock applications. The high performance PLL has a figure of merit of (read more)
Browse Frequency Synthesizers Datasheets for Richardson RFPD -
performance in applications requiring deterministic behaviour. With its combination of wireless flexibility and direct analog output, the WSDA-101 is intended for engineers seeking a practical way to incorporate wireless sensor data into established industrial and laboratory systems (read more)
Browse Data Acquisition Systems and Instruments Datasheets for Hottinger Brüel & Kjær A/S
More Information Top
-
Air Quality and Emission Measurement Methodology at Swine Finishing Buildings
… manifold Machine shop constructed, 3.8 cm × 46 cm 16 3,000 Mixing manifold Machine shop constructed, 3.8 cm × 31 cm 16 2,000 Flow rotameter Dwyer Model VFA-24 … … 5,200 Temperature sensors Analog Devices No. SNSR-AD592 … … input CIO-DAS-TEMP 4 3,200 Relay interface board SSR-RACK24 6 1,000 3-32 VDC input relays SSR-IDC-05 20 200 0-60 VDC output relays SSR-ODC-05 … … less than 60 s with insignificant losses in accuracy …
-
Development and testing of industrial scale, coal fired combustion system, Phase 3. Third quarterly technical progress report, July 1, 1992--September 30, 1992
The three new combustor cooling water flow sensors, whose outputs were logged by the computer, appear to have operated properly in test DP2, yielding flows that were in global agreement with flows previously measured by rotameters and dial gauges. … test priorities, the individual sensor flows were not systematically verified against the corresponding analog device during DP2.
-
In vitro assessment of infant pulmonary function equipment
The resistance of the PNT was assessed bidirectionally using known flows of air from the calibrated rotameters and measuring the pressure drop across the apparatus with a Validyne MP45 2 50 cm H,O pressure trans- ducer. The output of the transducer was digitized at 200 Hz, using an Analog Devices A-D converter, and data was collected on an I[BMcompatible 386 personal com- puter using RASP software (Respiratory Analysis Pro- gram, Physio Logic, Newbury, England).
-
Measurement of Endogenous Nitric Oxide Production
An Ohmeda TVX volume sensor clip was placed on the rotameter in the expiratory limb of the … Analog signals of the end tidal CO2 and £ow waveforms were passed through a self-designed signal noise … … recorded on 2-channel strip chart recorders (Kipp & Zonen, Bohemia, New York, U.S.A.) along with the output of the NO chemiluminescent …
-
The development of small solar concentrating systems with heat storage for rural food preparation
A rotameter (variable area £ow meter) is installed in line with the £ow meter to check the calibration of the electrical £ow meter. The output digital and analog signals of the DACS can be controlled by the personal computer.
-
Controllers implementation based on softcomputing for non-linear process
… up for this system consists of a spherical tank , a water reservoir, pump, rotameter , a differential pressure … The differential pressure transmitter output is interfaced with computer using ADAM’s 5000 Advantech module in the RS- 232 port of the PC. This module supports 8 analog input and 4 analog output channels with the voltage range of ±10 …
-
Minimum spouting velocity of dense particles in shallow spouted beds
The MFC was controlled by the National Instrument (NI) computer via analog output ports on the NI PXI 6052E data acquisition card driven by NI computer. One part of the air passed through a rotameter (used for controlling the flow split) and a humidifier before recom- bining with the remaining part of air and flowing on to the spouted bed inlet.
-
Measurement of dynamic gas disengagement profile by using an analog output level gauge
The analog output gauge is connected to a data acquisition board which in turn is calibrated to record the gas liquid dispersion height in feet units. … by filling the column up to a certain level (above 1 m height) with liquid and recording … Air was introduced through a rotameter , and a gas distributor into the column.
-
Dynamics of heat transfer to cold eggs in incubating bantam hens and a black grouse
Water flow trough the eggs was kept constant with a rotameter and measured with a measuring cylinder over three f-min periods. The thermocouple amplifiers, thermopile and electri- cal output from the O2 analyser were connected to an analog to digital converter (A/D) connected to a computer .
-
Air Quality Monitoring and On-Site Computer System for Livestock and Poultry Environment Studies
These include gas tubes, regular rotameters , handheld anemometers, psychrometers, and certain gas monitors (e.g., electrochemical gas … Type 1 and Type 2 devices are readily connectable to an on-site computer, as are Type 3 devices with analog outputs .
Indicates content that may require registration and/or purchase.