Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Metrohm USA, Inc.
Description: ECO semi-micro titration equipment
-
Supplier: Metrohm USA, Inc.
Description: Additional equipment for Robotic Sample Processors XL for direct titration in sample vessels of 75 mL and more.
-
Supplier: Metrohm USA, Inc.
Description: Complete accessory set for volumetric Karl Fischer titration.
- Titrant Adding Method: Volumetric
-
-
Supplier: Metrohm USA, Inc.
Description: Complete accessory set for volumetric Karl Fischer titration
- Titrant Adding Method: Volumetric
-
Supplier: ASTM International
Description: (typically 10 μg H2O). This test method requires the use of equipment specifically designed for coulometric titration. 1.2 This test method recommends the use of commercially available coulometric Karl Fischer titrators and reagents. 1.3 The values stated in SI units are to be regarded
-
Supplier: ASTM International
Description: with the exclusion of carbon dioxide. 1.1.1 Test Method A-Developed specifically for measurement of acidity by potentiometric titration. This is the referee method. 1.1.2 Test Method B-Developed specifically for measurement of acidity by color end point titration. 1.2 The ethanol and
-
Supplier: ASTM International
Description: This standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of whoever uses this standard to consult the established and appropriate safety and health practices
-
Supplier: ASTM International
Description: Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid procedures, and safety precautions and proper personal protective equipment. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This
-
Supplier: Hamilton Company
Description: The Liq-Glass Knick® is a robust electrode for daily laboratory use, ideally suited for titrations with strong acids as well as in strong bases. It is especially well suited for Knick Portamess® equipment.
- pH Range: 0 to 14 ph
- Operating Temperature: 14 to 212 F
- Electrode Configuration: Combination
- Body Material: Glass
-
Supplier: Hamilton Company
Description: The Liq-Glass Knick® is a robust electrode for daily laboratory use, ideally suited for titrations with strong acids as well as in strong bases. It is especially well suited for Knick Portamess® equipment.
- pH Range: 0 to 14 ph
- Operating Temperature: 14 to 212 F
- Electrode Configuration: Combination
- Body Material: Glass
-
Supplier: Hamilton Company
Description: The Liq-Glass Knick® is a robust electrode for daily laboratory use, ideally suited for titrations with strong acids as well as in strong bases. It is especially well suited for Knick Portamess® equipment.
- pH Range: 0 to 14 ph
- Operating Temperature: 14 to 212 F
- Electrode Configuration: Combination
- Body Material: Glass
-
Supplier: Hamilton Company
Description: The Liq-Glass Knick® is a robust electrode for daily laboratory use, ideally suited for titrations with strong acids as well as in strong bases. It is especially well suited for Knick Portamess® equipment.
- pH Range: 0 to 14 ph
- Operating Temperature: 14 to 212 F
- Electrode Configuration: Combination
- Body Material: Glass
-
Supplier: Chemetall
Description: enable the R&D and production of engineered fluids. Some of the equipment includes: Diamond Dispersion/Sonication Equipment - ultrasonic equipment for dispersion of sub-micron and nanometer sized diamond particles Flow Cells for Sonication - inline and continuous, large volume,
- Type: CMP / Wafer Planarization, Cleaning / Surface Preparation, Grinding, Lapping, Polishing
- Form: Slurry
-
Supplier: Parco Scientific Company
Description: A portable outfit with simplified testing of nine essential nutrients at an economical price. Colorimetric tests use Octet Comparators with permanent color standards for accurate visual color comparison. Simplified titration procedures use specially calibrated Direct Reading Titrators.
- Trainer Type: Training Kit / Modular Unit
-
Supplier: Dymax
Description: dispenser. The contaminate-free dispensing this pipette offers is ideal for lab applications or other work with sterile fluids. Some common uses include: Radioimmunoassay Tissue culture Histo-compatibilty Enzyme immunoassay Titration Pathogenic material Sterile procedure Precise inoculations
- Dispensing Equipment Type: Dispense Only
- Features: Other
-
Supplier: Environics, Inc.
Description: to 3 thermal mass flow controllers, an ozone generation module, photometer, glass output manifold, mixing chamber, a reaction chamber for gas phase titration, and control electronics. Commands are entered from the front panel and displayed on a backlit 4 line by 20 character liquid crystal
- Output Flow Rate: 0.1000111361652 to 1,000 SLM
- Generator Type: Ozone
- Features & Approvals: Portable
- Features: Specialty / Other
-
Supplier: Environics, Inc.
Description: circuit to dilute ammonia without risking the degradation of the ozone circuit. The Series 6100 consists of a single chassis supporting up to 3 thermal mass flow controllers, an ozone generation module, a mixing zone, a reaction chamber for gas phase titration, and control electronics. Units
- Output Flow Rate: 0.1000111361652 to 1,000 SLM
- Generator Type: Ozone
- Features & Approvals: Portable
- Features: Specialty / Other
-
Supplier: Environics, Inc.
Description: generation module, a mixing zone, a reaction chamber for gas phase titration, and control electronics. Commands are entered from the front panel and displayed on a backlit 25 line by 80 character liquid crystal display. The instrument may also be operated using contact closures or an RS-232
- Output Flow Rate: 0.1000111361652 to 1,000 SLM
- Generator Type: Ozone
- Features & Approvals: Portable
- Features: Specialty / Other
-
Supplier: TCI America
Description: Arsenazo III [Spectrophotometric reagent for U, Th, Zr and other metals, Indicator for the precipitation titration of SO4 with Ba] / 2,7-Bis(2-arsonophenylazo)-1,8-dihydroxynaphthalene-3,6-disulfonic Acid Photometric ReagentsWith the development of new analytical equipment and methods,
-
Supplier: Venable Instruments
Description: Supported Constant Charging and Discharging (current or voltage)Constant Power or Load Linear Sweep Voltammetry (LSV)Cyclic Voltammetry (CV)Step Voltammetry Pulse Voltammetry [e.g., square wave voltammetry (SWV)]Electrochemical Impedance Spectroscopy Potentiostatic Intermittent Titration
- Test / Technique: Charge / Condition, Impedance / AC Testing
- Features: Other, Specialty / Other
- Form: Test Station / System
-
Supplier: Gemu Valves
Description: industries, the chemical industry, electroplating, titration equipment, for the photo graphic industry and for laboratory, analytical and medical apparatus. Advantages Hermetic separation of medium and actuator Manual override allows the valve to be opened and closed during a power
- Valve Size: 0.2362206 to 0.393701 inch
- Pressure Rating: 21.755655 to 87.02262 psi
- Media Temperature: 140 to 212 F
- Number of Ports/Ways: 2
-
Supplier: Haida International Equipment Co., Ltd.
Description: Purpose: Trace Moisture Analyzer is the Coulomb and Karl - Philippine Hugh method has effectively combine applications Determination of water consumption of the new equipment. The instrument overcomes the card you - Philippine Hugh method is cumbersome on the shortcomings of using a large
- Operating Temperature: 32 to 104 F
- Form Factor: Instrument
- Variables Measured: Moisture Content
Find Suppliers by Category Top
Featured Products Top
-
The 2060 Raman Analyzer is a non-destructive inline process analyzer that implements Raman spectroscopy to deliver accurate and real-time process monitoring. Thanks to its self-monitoring capabilities, high-throughput spectrometer, and long-lasting laser stability, it provides immediate insights into chemical composition and enables timely adjustments for optimal process control,...
(read more)
Browse Raman Spectrometers Datasheets for Metrohm USA, Inc. -
Converting Validated Manual Titrations to Automated Titrations During this webinar, Dr. Ernest Parente, Principal Scientist at Cardinal Health Regulatory Sciences, gives recommendations for converting USP manual titration procedures into automated titration procedures. He discusses how to implement the USP compendial tools to demonstrate equivalence between compendial and alternative methods. (read more)
Browse Titration Instruments Datasheets for Metrohm USA, Inc. -
OMNIS titrators are high-end automatic titrators for potentiometric titration that allow you to consolidate all your titration applications on a single platform for efficient and safe analyses. Various customization and automation options are available and, thanks to the modular design, you can (read more)
Browse Titration Instruments Datasheets for Metrohm USA, Inc. -
to determine alkalinity, hardness and LSI in the field. This eliminates the need to collect and transport samples to another location for analysis. User intuitive display prompts guide you through titration procedures from start to finish. All required reagents and equipment are included in the 9P (read more)
Browse Oxidation Reduction Potential (ORP) Instruments Datasheets for Myron L Company -
generated from inline pH sensors, NIR spectrometers, and online wet chem analyzers performing titrations and photometric analyses. Watch the Webinar (read more)
Browse Infrared Spectrometers Datasheets for Metrohm USA, Inc. -
2060 Platform, it seamlessly integrates multiple analysis techniques into one unified platform. Experience the power of combining XRF with titration or photometry for comprehensive process insights like never before. (read more)
Browse X-Ray Fluorescence Spectrometers Datasheets for Metrohm USA, Inc. -
The Ultrameter III 9P is a cost-effective comprehensive water quality analysis kit with one-button electrometric functions and in-cell titrations. Ultrameter III 9P measures conductivity/resistivity/TDS, ORP/free chlorine, pH, temperature, alkalinity, and hardness. Its LSI calculator (read more)
Browse Water Quality Testing Instruments Datasheets for Myron L Company -
Features Include: FAST - one-touch measurements for Conductivity, Mineral/Salt Concentration, TDS, ORP (REDOX), Free Chlorine, pH and Temperature SIMPLE - user-intuitive prompts step you through Alkalinity, Hardness and LSI titrations (PS9 (read more)
Browse Water Quality Testing Instruments Datasheets for Myron L Company -
Hydraulic systems are used in industrial, mobile and aviation applications to transmit power to operate equipment. They are incredibly efficient, compact, and lightweight relative to a mechanical equivalent. Hydraulic fluids transmit force in the system, and as such are carefully chosen by the (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
, allowing severe wear to occur with resulting high frictional heat. Water contamination should not exceed 0.25 % for most equipment, though centrifugal pumps used in power plants specify much tighter limits such as 500 ppm for boiler feed pump bearings. A number of new technologies exist to detect (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific
Conduct Research Top
-
What's Titration and Why Should I Care?
When dealing with aqueous parts cleaning, it's important to control the concentration of your aqueous solution in order to achieve ideal cleaning status and extend your bath life.
-
The Simple Truth about Karl Fischer Moisture
The Karl Fischer method is a titration of Sulfur Dioxide, Iodine and Pyridine that uses up water. From its inception in 1925, Karl Fischer Titration has become an ever increasing solution to tough moisture measurement problems. Because it separates moisture from other components and only measures
-
Therapeutic Dose: Avoiding "Cool Hand Luke " Syndrome: Part II
chemistry within the broader framework of chemistry. For those people, it s "pharma versus everyone else. " For example, years ago, when I worked at a surfactant company, I remember that we had once had to run a simple two-layer titration method for sodium lauryl sulfate (SLS or sodium dodecyl
-
Concentration Measurement
by. more that one concentration test method. Each concentration method measures a specific chemical, group. of chemicals or fluid characteristic. Typical concentration measurements are: Total Alkalinity (TA). BCG Titration (BCG). Refractometer. CIMCHEK (R) Test Strips. Total alkalinity is a pH based
-
Avoiding Machinery Wear and Corrosion
. When moisture is present on a metal surface, an oxidative chemical reaction can take place. Like all chemical reactions, temperature increases expedite the process, causing premature wear. Water content of lubricating oils has typically been measured by performing a Karl Fischer titration. While
-
The Best of Pittcon 2007
Operational Excellence & Lean Six Sigma ), which introduced titration and materials characterization products, measurement instruments and microbalances. Of particular interest was the new LiQC (for liquid quality control) system for simultaneous determination of density, refractive index, pH
-
Determination of Water Hardness
Originally the hardness of water was defined as the capacity of water for destroying the lather of soap. The hardness was determined by a titration with a standard soap solution. Metal ions including have the ability to cause hardness. However, today water hardness means the total calcium
-
Pure Chlorite Standard Developed
chlorite was developed at our facilities between 1998 and 2001. The final product is a Certified Reference Material that is certified by Iodometric Titration and Ion Chromatography. Currently, we have one year of stability data on the first lot of 1K ClO2- and our study is ongoing.
-
Method for Computing Alkalinity Based On Total Inorganic Carbon (TIC) and Related Data (.pdf)
Standard Methods (Ref. 1) has a procedure using nomographs for estimating CO2 concentrations (Method 4500-CO2 B) based on total alkalinity titrations. The method presented here reverses that process by computing alkalinity based on TIC measurements using infrared technology. These two methods
-
Waterbased Metalworking Fluids: Proper Mixing Practices
concentration is correct. The concentration can be measured with a CIMCOOL Refractometer, CIMCHEK TM test strips or a chemical titration method. Concentration may be expressed as a percentage or as a ratio of the amount of metalworking fluid concentrate to the total volume of mix. Example: Adding 4
-
Real-Time Nitrite Detection for Hot Water Boiler and Cooling System
its concentration above a certain level to prevent localized corrosion from happening. Monitoring of nitrite is most commonly done by grab sample testing. The testing is typically done using kits that rely on drop count titration methods which may require a third-party service company to visit
More Information Top
-
Titration and therapy by means of positive-pressure breathing by schlafbezogenen breathing disorders (SBAS)
The selection of the optimal pressure for constant-CPAP therapy of the data of the automatic titration night must both the evaluation of the Polysomnographie, and the pressure profile stored in the titration apparatus and that pressure stages determined by the system …
-
UOP 212 - HYDROGEN SULFIDE, MERCAPTAN SULFUR, AND CARBONYL SULFIDE IN HYDROCARBON GASES BY POTENTIOMETRIC TITRATION
However, if only manual titration equipment is available, manual titration can be performed.
Indicates content that may require registration and/or purchase.