Fill out as many options as you want. Click "Run Search Filter" at any time.

Power Source:

Cooling Capacity:

Fluid Discharge Temperature:

Compressor Motor Horsepower:

Process Flow:

Process Pressure:

Pump Rating:

Reservoir Capacity:

Full Load Amperage:

Condenser Cooling:

Control Panel Features:

Other Features:

Operating Temperature:

Help with HVAC Chillers specifications:

Power Source
   Power Source      Specifications are Voltage / Frequency / Phase.  
   Your choices are...         
   115 / 60 / 1         
   230 / 50 / 1         
   208-230 / 60 / 1         
   208-230 / 60 / 3         
   380 / 50 / 3         
   460 / 60 / 3         
   575 / 60 / 3         
   Other Power       Other unlisted power source. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Cooling Specifications
   Cooling Capacity:       Total capacity of the chiller to remove heat from the process fluid. Typical units are kilowatts, tons of refrigeration, or BTU/hour. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Fluid Discharge Temperature:       Required temperature of fluid discharge. 
   Search Logic:      All matching products will have a value less than or equal to the specified value.
   Compressor Motor Horsepower:       This is a nominal value by which chillers can be approximately specified. True differentiating specifications are capacity and discharge temperature. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
Back to Top
Process Pump Specifications
   Process Flow:       Required flow capacity of pump. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Process Pressure:       Required developed pressure of pump. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Pump Rating:       Horsepower rating of pump. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
Back to Top
Other Specifications
   Reservoir Capacity:       Cooling medium reservoir size. 
   Search Logic:      User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria.
   Full Load Amperage:       Current draw of unit when operating at full cooling capacity. 
   Search Logic:      All matching products will have a value less than or equal to the specified value.
Back to Top
Condenser Cooling
   Condenser Cooling       
   Your choices are...         
   Air-Cooled       Forced air, usually via fan, passes over condenser coils for cooling. 
   Water-Cooled       Condenser coils are cooled with circulating water. 
   Remote Air / Split System       Split systems are configured with the main chiller system in the application area, and the condenser is remotely located, often outdoors.  The cooling air is supplied remotely to the chiller system. 
   Other       Other unlisted, specialized, or proprietary condenser configuration. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Control Panel Features
   Control Panel Features       
   Your choices are...         
   Local Control Panel       Setup / control panel on chiller enclosure. 
   Remote Control Panel       Controller located separately from chiller unit. 
   Temperature Indicators       Gauges or readouts for operating temperature. 
   Pressure Indicators       Gauges or readouts for operating pressure. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
   Other Features       
   Your choices are...         
   Microprocessor Control       Computerized controller available for more precise programming of chiller performance. 
   Outdoor / Weatherproof       Constructed and rated for installation on the outside of a building, rooftop mounting, etc. 
   Modular Configuration       System designed is separated into components for flexible mounting and placement configurations. 
   Integral Pump       Chiller contains integral pumping capacity 
   Emergency Alarms       Signals or alarms for emergency events such as overtemperature, low coolant, etc. 
   Hot Gas Bypass       Hot gas diverted to condenser to minimize inefficient compression. 
   Search Logic:      All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
Back to Top
Environment
   Operating Temperature:       This is the full required range of ambient operating temperature. 
   Search Logic:      User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria.
Back to Top