Help with Incubators specifications:
Configuration
Back to Top
|
|
| ||
| Jacket Type: | |||
| Your choices are... | |||
| Air Jacket | Air draft incubators are popular among larger-volume models designed to allow for quicker recovery times. Air draft (or forced draft) incubators circulate air throughout the interior of the incubator to maintain constant temperatures. | ||
| Direct Heat | Direct heat provides gentle convection circulation of chamber atmosphere to produce a uniform incubating environment. | ||
| Dry Wall | Dry wall incubators have the advantage that they can better adapt to ambient changes and require less maintenance. | ||
| Water Jacket | Water-jacketed incubators advantages include stable temperature control and increased security in the event of power failure (due to water's natural insulation abilities). | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
| Carbon Dioxide Sensor Type: | |||
| Your choices are... | |||
| Infrared Sensor | For applications requiring several door openings, IR sensors will provide accurate CO2 readings without having to wait for humidity to stabilize. Incubators with IR sensors will generally cost slightly more than the same incubator with a TC sensor. Currently, many sensors are constructed of platinum, which some manufacturers claim stands up to corrosion quite well. | ||
| Thermal Conductivity Sensor | Thermal conductivity sensors measure changes in temperature internally and have proven their effectiveness through time. These sensors, however, are sensitive to changes in humidity. Infrared CO2 sensors measure diffraction of CO2 internally and are purportedly impervious to relative humidity and less susceptible to drift over time because they have auto-zero calibration cycles every few hours. | ||
| Other | Other unlisted or proprietary sensor technology. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Performance Specifications
Back to Top
|
|
| ||
| Chamber Capacity: | The volume of the chamber that is available for testing the product. | ||
| Search Logic: | User may specify either, both, or neither of the "At Least" and "No More Than" values. Products returned as matches will meet all specified criteria. | ||
| Temperature Range: | The temperature range over which the test chamber will test. | ||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||
| Temperature Control Accuracy: | The closeness of an indication or reading of a measurement device to the actual value of the quantity being measured. Usually expressed as percent of full-scale output or reading. | ||
| Search Logic: | All matching products will have a value less than or equal to the specified value. | ||
| Relative Humidity: | The humidity range over which the test chamber will test. | ||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||
| Carbon Dioxide Range: | The range of atmosphere that the incubator can produce. | ||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||
| Carbon Dioxide Control: | The degree of control of carbon dioxide that the incubator can achieve. | ||
| Search Logic: | All matching products will have a value less than or equal to the specified value. | ||
User Interface Options
Back to Top
|
|
| ||
| Local Interface: | |||
| Your choices are... | |||
| Analog Front Panel | The panel has analog user inputs such as potentiometers, dials, switches, for adjustment of output, ranges, etc. | ||
| Digital Front Panel | The panel uses digital keypads or menus for programming. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
| Computer Interface? | Can be controlled or monitored remotely with a computer via interface. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
| Computer Interface Options: | |||
| Your choices are... | |||
| Serial Interface | A port, or interface, that can be used for serial communication, in which only one bit is transferred at a time. Examples include RS232, RS422, RS485, USB etc. | ||
| Parallel Interface | A channel capable of transferring more than one bit simultaneously. Examples include PC Printer Port, Centronics etc. | ||
| Other Computer Interface | Modem, transmitter, TTL, etc. | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
| Application Software Included? | For control or for monitoring the process. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
| Display Type: | |||
| Your choices are... | |||
| Analog Meter | The unit has an analog display such as a dial or indicator lights. | ||
| Digital Numerical Display | Has display for numerical values | ||
| Video Display | CRT, LCD or other multi-line display | ||
| Search Logic: | All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches. | ||
Features
Back to Top
|
|
| ||
| Built-in Alarms? | The incubator has audio or visual alarms to alert the user to specific conditions. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
| Adjustable Door Heater? | The incubator has an adjustable door heater. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
| Stackable? | The incubator is stackable to conserve floor or benchtop space. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
| Interior Lights? | The incubator has interior lights to allow viewing. | ||
| Search Logic: | "Required" and "Must Not Have" criteria limit returned matches as specified. Products with optional attributes will be returned for either choice. | ||
Environment
Back to Top
|
|
| ||
| Operating Temperature: | This is the full required range of ambient operating temperature. | ||
| Search Logic: | User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria. | ||