Products/Services for Inhibited Hydrochloric Acid
-
Inorganic Chemicals and Compounds - (900 companies)...sodium, potassium and magnesium. The top 20 inorganic chemicals manufactured in Canada, China, Europe, India, Japan, and the US (2005 data) are: aluminum sulfate ammonia ammonium nitrate ammonium sulfate carbon black chlorine hydrochloric acid hydrogen...Inorganic CompoundsAcidsBases
-
Lead Acid Batteries - (379 companies)Lead acid batteries are made up of plates, lead, and lead oxide with a 35% sulfuric acid and 65% water electrolyte solution. Lead acid batteries are rechargeable batteries consisting of lead plates with a sulfuric acid/water electrolyte solution...
-
Rust and Corrosion Inhibiting Fluids - (390 companies)Rust preventives and corrosion inhibitors are lubricants, greases, oils or fluid additives that form a protective film or barrier to prevent corrosion or rust formation.
-
Floor Scrubbers - (154 companies)Floor scrubbers are machines used to clean large surface areas such as walkways, roads, factory floors and parking areas.
-
Neutralization Equipment - (41 companies)...quantities of hydrochloric acid (HCl) and sodium hydroxide (NaOH) are mixed and then the change in temperature is measured with large read-out digital thermometers. A deionized water system removes all ions from a solution using neutralization...
-
Etchers and Etching Machines - (64 companies)...corrosive, such as hydrochloric acid, to etch the surface of the wafer. Photoresists are masks that become soluble or insoluble to the etchant based upon their exposure to light. These types of etchers and etching machines use wet etching processes...
-
Bricks - (118 companies)Bricks consist of fired ceramic or cement materials with a rectangular shape. Different bricks are available for specific applications such firebricks or refractory bricks, acid bricks for flooring and red bricks for masonry applications. Bricks...
-
Gel Electrophoresis Equipment - (64 companies)Gel electrophoresis equipment, instruments and supplies are used to separate macromolecules, either nucleic acids or proteins, on the basis of size, electric charge, and other physical properties. Gel electrophoresis equipment, instruments...
-
Paint Brushes and Applicators - (74 companies)Paint brushes and applicators are used to apply paints, adhesives, sealants, oils, cleaners, acids or etchants, mortar or cement treatments, and other coating products to surfaces. There are many different types of paint brushes and paint rollers...
-
Electrolytes - (31 companies)OSHA). Types. Other liquid electrolytes for batteries, fuel cells, and capacitors include: aqueous sodium chloride. hydrochloric acid. aqueous sodium hydroxide. There are two basic types of solid electrolytes: point defect and solid state. Along...
Product News
-
ExxonMobil Chemical Company - Polypropylene Products
Neo Acids ExxonMobil neo acids exhibit highly branched structures in which the carboxylic group is attached to a quaternary carbon atom where R1, R2 and R3 are alkyl groups. The high steric hindrance provided by the neo acid structure imparts excellent thermal and hydrolytic stability in derivatives and also helps make neo acids a superior building block for coatings derivatives. Benefits. Very high thermal and hydrolytic stability of derivatives. Easy transportation, storage and handling of neo-decanoic... (read more) -
High Performance Alloys, Inc.
Nickel resistance to corrosion in acids & alkalis Commercially pure wrought Nickel with good mechanical properties over a wide range of temperature and excellent resistance to many corrosives, in particular hydroxides. Good resistance to corrosion in acids and alkalis and is most useful under reducing conditions. Outstanding resistance to caustic alkalis up to and including the molten state. In acid, alkaline and neutral salt solutions the material shows good resistance, but in oxidizing salt solutions severe attack will occur. Resistant... (read more)Browse Nickel and Nickel Alloys Datasheets for High Performance Alloys, Inc. -
Branch Environmental Corp.
How to Remove Acid from Gas to compensate by closing the Venturi throat. An automatically adjustable design is included when necessary. Branch will make recommendations on the best design for your specific case. Branch Environmental supplies custom built pollution control equipment for industry. Our air pollution control equipment can clean up acids, organics, aerosols and mist to meet any emission control standards. Our equipment is also used for water treatment, including removal of volatile organics, ammonia and other gases. (read more)Browse Scrubbers Datasheets for Branch Environmental Corp. -
Asahi/America, Inc.
ECTFE (Halar®) Piping Sulfuric Acid Best Practices Based on Asahi/America 's decades-long experience supplying single and double contained pipe systems with sulfuric acid, we are pleased to make the following material compatibility recommendations. For the premier recommendation with the highest reliability, Ultra Proline (R) ECTFE by Asahi/America provides 25+ year service life with up to 98.3% sulfuric acid. View the guide. (read more) -
ExxonMobil Chemical Company - Polyethylene Products
Ethylene and acrylic acid (EAA) copolymer resins EAA copolymers. Ethylene and acrylic acid (EAA) copolymer resins offer excellent adhesion to polar substrates without the need for primers. Applications include liquid aseptic, dry-food and laminated tube container packaging, and cable shielding. Escor TM EAA copolymer resins. Offers excellent adhesion to polar substrates without the use of primers. Applications include liquid aseptic and dry-food packaging, laminate tubes and cable shielding. Benefits. Adhesion to a range of polar substrates... (read more)Browse Resins and Compounds Datasheets for ExxonMobil Chemical Company - Polyethylene Products -
Branch Environmental Corp.
Why Consider a Packaged System for VOC Control? Packaged Systems. For some applications on oxidizers, the destruction of the compound results in other chemicals which can still not be released to the atmosphere. For example, if you destroy a chlorinated organic, the final flue gas may contain HCl (Hydrochloric acid). If the quantity of HCl is significant, we can add a cooling system and a scrubber system to eliminate any acid emissions and convert the acid HCl to a neutral salt. Branch Environmental can provide the complete coordinated... (read more)Browse Thermal Oxidizers and Catalytic Oxidizers Datasheets for Branch Environmental Corp. -
Texel-Seikow USA, Inc.
TEXEL sealless mag drive pump MTA Series and manufacturing technology for resin pumps. All flange sizes comply with ANSI/ASME B16.5 pipe flanges and flanged fittings standards. MTA Pump specifications. Product Category: Centrifugal Pump. Total Head: 33 - 265 ft. Liquid Flow: 40 - 793 GPM (150 - 3000 l/min). Discharge Size: 1.0 - 4.0 inch (2.5 - 10 cm). Motor HP: 2 - 50 HP (1.5 - 37 kW). Pump Casing Material: PFA, ETFE. Power Source: DC. Pump Type: Magnetic Drive Pump, Sealless Pump, Chemical Pump. Media: Hydrochloric Acid, Caustic Soda, Sulfuric... (read more)Browse Magnetic Drive Pumps Datasheets for Texel-Seikow USA, Inc. -
High Performance Alloys, Inc.
Inconel ® 625 (N06625) at elevated temperatures up to 1050C. Good resistance to acids, such as nitric, phosphoric, sulfuric and hydrochloric, as well as to alkalis makes possible the construction of thin structural parts of high heat transfer. Applications. Components where exposure to sea water and high mechanical stresses are required. Oil and gas production where hydrogen sulfide and elementary sulfur exist at temperature in excess of 150C. Components exposed to flue gas or in flue gas desulfurization plants... (read more)Browse Superalloys Datasheets for High Performance Alloys, Inc. -
Plast-O-Matic Valves, Inc.
Chemical handling valves hydrochloric acid metering, sulfuric acid dosing, and anti-scalant addition. Plast-O-Matic Valves series RVDT by-pass/back pressure valves, calibration columns, injection quills, pulsation dampeners, gauge guards, check valves, sight glasses and ball valves with characterized ball profiles are designed to meet and exceed the most rigorous demands in virtually any water treatment or chemical metering system application. Our chemical handling valve designs offer extraordinarily high cycle life... (read more)Browse Pressure Relief Valves Datasheets for Plast-O-Matic Valves, Inc. -
Xiamen Innovacera Advanced Materials Co., Ltd.
Hot-Pressed Aluminum Nitride ceramic components features: Excellent thermal conductivity. High electrical insulation. High dielectric strength. Resist high temperature and corrosion. Thermal expansion coefficient similar to Si, GaN, and GaAs semiconductors. Suit for rigorous or abrasive environments. Can 't be eroded by all kinds of molten metals and molten hydrochloric acid. Hot- Pressed aluminum nitride ceramic part application: Semiconductor heaters. Magnetic resonance imaging equipment. Etching machine. Integrated... (read more)Browse Industrial Ceramic Materials Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd.
-
Industrial Chemical Cleaning
Engle, et alP) have shown that aus- tenitic stainless steels are not attacked by inhibited hydrochloric acid at 150°F.
-
Localised corrosion at welds during acid cleaning
In inhibited hydrochloric acid it has been shown that undesirably high weight losses are associated with pitting and a pitting potential below which pits will not initiate can be determined.
-
Electrochemical and thermodynamic studies to evaluate the inhibition effect of synthesized piperidine derivatives on the corrosion of mild steel in acidic medi...
Activation parameters such as the activation energy (Ea), activation enthalpy (ΔH*), Arrhenius pre-exponential factor (A) and activation entropy (ΔS*) for both uninhibited and inhibited hydrochloric acid solution for MS in 0.5 M HCl in the absence and presence of various…
-
Practical Boiler Water Treatment Handbook
If mill scales are known to be present, the alkaline boil out has to be followed by an acid cleaning using 5% inhibited hydrochloric acid .
-
Operation and Maintenance of Thermal Power Stations
If condensers are to be cleaned frequently (i.e., more than once per year-see Appendix 2E), it is necessary to use inhibited hydrochlo- ric acid or inhibited sulfuric acid .
-
Gas Well Stimulation Increases Production and Profits
Acidizing Techniques Acidizing treatments using inhibited hydrochloric acid to enlarge pores and flow channels have been used successfully for many years.
-
SDG and E - ERDA Geothermal Loop Experimental Facility. Bi-monthly report, May 1975-August 1976
soaking i n a 20% inhibited hydrochloric acid .
-
Corrosion Inhibition of Mild Steel in Hydrochloric
Acid by Tannins from Rhizophora Racemosa
Studies on the corrosion behaviour of mild steel electrodes in inhibited hydrochloric acid are described.
-
Corrosion and Materials Selection: A Guide for the Chemical and Petroleum Industries
The maximum temperature for inhibited hydrochloric acid used for cleaning cast iron in petroleum refinery equipment is 51∘ C (125 ∘ F), while other metals can be cleaned safely at 77 ∘ C (170 ∘ F).
-
Nalco Guide to Boiler Failure Analysis, Second Edition > Corrosion during Cleaning
Inhibited hydrochloric acid .