Analog Current Flame Detectors

13 Results
Flame Detector -- FL500 UV/IR
from MSA Safety

The General Monitors® FL500 UV/IR Flame Detector by MSA delivers fast, dependable flame detection with enhanced false alarm immunity-all in a compact, industrial-grade design. By monitoring both ultraviolet (UV) and infrared (IR) radiation, the FL500 provides rapid response to real flames while... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal; Sink or Source Analog
  • Max Response Time: 3.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 45 to 90
Flame Detector -- FL500-H2 UV/IR
from MSA Safety

The General Monitors® FL500-H2 UVIR Flame Detector by MSA delivers high speed flame detection with increased false alarm immunity in a compact design for hydrogen flame detection. The FL500-H2 UV/IR Flame Detector monitors for radiation emitted by a hydrogen flame in both the ultraviolet (UV) and... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal; Sink or Source Analog
  • Max Response Time: 3.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 60
Multi-spectrum Infrared Flame Detector -- FL5000 MSIR
from MSA Safety

The MSA General Monitors® FL5000 MSIR Flame Detector sets a high standard in industrial fire protection with advanced multi-spectrum IR sensing and AI-driven flame recognition. It detects fires up to 310 feet away while minimizing false alarms from sources like sunlight or lightning. The detector is... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal
  • Max Response Time: 10.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 70 to 310
Multi-spectrum Infrared Flame Detector -- FGD-PDS-975MR
from Emerson Automation Solutions – Rosemount

State-of-the-art multi-spectrum infrared technology detects hydrocarbon fuel and gas fires while delivering superior reliability and immunity to false alarms with enhanced overall coverage. Make the right decision when it counts — when safety is on the line. Enhance safety and minimize trips... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Relay
  • Max Response Time: 5.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 215
Continuous Flare Stack Mopnitoring System -- E²T Quasar 2 M8100-EXP
from LumaSense Technologies, Inc., An Advanced Energy Company

The E ²T Quasar 2 instrument provides continuous monitoring and detection of pilot flame and flared gases from flares. Safe flare operation and environmental protection require reliable and accurate flare pilot monitoring. Flare pilots are often monitored with thermocouples, but they often fail... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA)
  • Max Detector Range (Sensitivity): 1312
  • Device Classification: Sensor
  • Sensor Technology: IR Detector Only
Multi-Spectrum QuadBand Triple IR -- FS24X
from Sensidyne, LP

Detects hydrocarbon and non-hydrocarbon fuel fires, minimal maintenance [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal
  • Max Response Time: 5.00
  • Device Classification: Sensor System
  • Max Detector Range (Sensitivity): 200
Fire Sentry Fire & Flame Detector -- FS20X
from Honeywell Analytics, Inc.

The Fire Sentry FS20X is the latest generation high technology Multi-Spectrum (UV/Dual IR/VIS) Fire and Flame Detector, which is part of the FSX family of advanced technology Electro-Optical Flame detectors. Based on the foundation of the highly successful and reliable Fire Sentry SS4 detector, the... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal
  • Max Response Time: 3.00 to 10.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 200
IR Flame Detector -- X9800
from Det-Tronics

Approved to FM 3260 (2000), the X9800 meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with both automatic and manual optical integrity test capability. The... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal; EQP Addressable, Pulse
  • Max Response Time: 0.04 to 15.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 2 to 85
Multi-spectrum Infrared Hydrogen Flame Detector -- FGD-PDS-975HR
from Emerson Automation Solutions – Rosemount

Multi-spectrum infrared sensing technology detects ‘invisible ’ hydrogen fires at long distances with high false alarm immunity. Optimize Safety Coverage. Long range detection of hydrogen based fires. Operate at your full potential. Enhanced false alarm immunity helps you reduce downtime... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Relay
  • Max Response Time: 3.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 66
Infrared Thermometer -- E²T Quasar M8100FM
from LumaSense Technologies, Inc., An Advanced Energy Company

Non-Contact Infrared Pyrometer Flare Monitor (FM): Multi-wavelength infrared thermometer sensitive to all flames including Hydrogen. The QUASAR Model M8100FM-EXP Flare Stack Flare Monitor provides continuous monitoring of flared gases from remote locations up to ¼ mile (400 m) away in nearly... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA)
  • Max Response Time: 0.01
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 1312
Fire Sentry Fire & Flame Detector -- FS24X
from Honeywell Analytics, Inc.

Fire Sentry FS24X is a quantum leap in flame and fire detection with its sophisticated software and detection technology. The Fire Sentry FS24X is the latest generation high technology Multi-Spectrum Triple IR (IR/IR/IR/Visible) Fire and Flame Detector, which is part of our FSX family of advanced... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal
  • Max Response Time: 3.00 to 10.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 200
Multispectrum Infrared Hydrogen Flame Detector -- Model X3302
from Det-Tronics

The X3302 brings state-of-the-art flame detection to the difficult task of detecting invisible hydrogen flames. With a solid cone of vision for Hydrogen fire detection, coupled with superior false alarm rejection, the X3302 provides protection in applications such as refineries, chemical loading,... [See More]

  • Output Options: Outputs an analog current signal (i.e., 4-20 mA); Output is a switch or alarm signal; Pulse/ LON
  • Field of View (Vertical/Horizontal): 90° by 75°
  • Device Classification: Sensor
  • Sensor Technology: Multi-IR Detector; Hydrogen Detection
Ultra Fast Ultraviolet Infrared Flame Detector -- FGD-PDS-975UF
from Emerson Automation Solutions – Rosemount

Innovative technology integrates ultraviolet and infrared sensors to rapidly detect hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires. Protect Critical Assets. Provides high speed response to explosive fires (20 msec). Identify Abnormal... [See More]

  • Output Options: Outputs an analog voltage signal; Outputs an analog current signal (i.e., 4-20 mA); Relay
  • Max Response Time: 3.00
  • Device Classification: Sensor
  • Max Detector Range (Sensitivity): 66