Voltage Thermopiles

38 Results
High Temperature Gas & Liquid Measurement Module
from Electro Optical Components, Inc.

Electro Optical Components offers high performance pyroelectric and thermopile detectors as well as IR sources. Detectors that measure radiation by means of the change of temperature of an absorbing material are classified as thermal detectors, often referred to as temperature sensor modules or... [See More]

  • Electrical Output: Current; Voltage; Serial; Other
  • Response Time: 30000
  • Temperature Range: -13 to 374
  • Detectivity: 1.11
Array Based Thermopile Detector -- SLA32
from Dexter Research Center, Inc.

Features: A 2 x 16 staggered element silicon-based thermopile array. Each active area is 0.05mm x 0.65mm with a time constant of 7ms and a very low Temperature Coefficient of Responsivity of -0.01%/ °C. It is packaged in a 38-pin DIP. Applications: Spectral analysis and line temperature... [See More]

  • Electrical Output: Voltage
  • Detectivity: 4.2 to 12
  • Responsivity: 93.2 to 186
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- DR26
from Dexter Research Center, Inc.

Features: A two-channel thin-film thermopile that offers low noise in a TO-5 package. Each small active area is 2mm x 0.6mm. This is our lowest noise-voltage two-channel detector. Applications: Security, intrusion detection and human presence monitoring, including identifying direction of travel. [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.2 to 2
  • Responsivity: 4.5 to 7
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- S25 TO-18
from Dexter Research Center, Inc.

Features: A single-channel silicon-based thermopile that offers the smallest single element active area size at 0.25mm x 0.25mm in a small TO-18 package. Delivers a very fast 12ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms. Delivers a very low Temperature... [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.44
  • Responsivity: 112
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- S25 TO-5
from Dexter Research Center, Inc.

Features: A single-channel silicon-based thermopile that offers the smallest single element active area size at 0.25mm x 0.25mm in a TO-5 package. Delivers a very fast 12ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms. Delivers a very low Temperature Coefficient of... [See More]

  • Electrical Output: Voltage
  • Detectivity: 2 to 3.2
  • Responsivity: 170 to 218
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- ST120 Dual
from Dexter Research Center, Inc.

Features: A two-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a very short thermal shock response... [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.09
  • Responsivity: 34.7
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- ST120 TO-5
from Dexter Research Center, Inc.

Features: A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 1.2mm x 1.2mm in a TO-5 package. Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a... [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.18
  • Responsivity: 37.9
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- ST150
from Dexter Research Center, Inc.

Features: A single-channel silicon-based thermopile that delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C with a high output voltage and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package. This detector has a very short thermal shock response... [See More]

  • Electrical Output: Voltage
  • Detectivity: 0.9500 to 1.8
  • Responsivity: 24.2 to 37.7
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- ST60 LCC
from Dexter Research Center, Inc.

Features: A single-channel silicon-based thermopile in a LCC package for surface mount assembly in a small active area of 0.61mm x 0.61mm. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a very... [See More]

  • Electrical Output: Voltage
  • Detectivity: 0.6900 to 1.44
  • Responsivity: 40.7 to 60.3
  • Operating Temperature: -58 to 212
Silicon Based Thermopile Detector -- ST60 TO-5
from Dexter Research Center, Inc.

Features: A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a... [See More]

  • Electrical Output: Voltage
  • Detectivity: 0.6900 to 1.44
  • Responsivity: 40.7 to 60.3
  • Operating Temperature: -58 to 212
ST60 Diffractive Lens
from Dexter Research Center, Inc.

Features. A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas and a 9 ° FOV. Delivers a very low... [See More]

  • Electrical Output: Voltage
  • Detectivity: 3.3 to 6.8
  • Responsivity: 196 to 285
  • Operating Temperature: -58 to 212
ST60 High Temperature
from Dexter Research Center, Inc.

A specially constructed MEMS based thermopile that will withstand operating temperatures of 300 °C with Silicon window and 225 °C with coated windows*. The reduced height (.090 ” tall cover) helps minimize the thermal path and gradient potential of the package. [See More]

  • Electrical Output: Voltage
  • Detectivity: 0.7900
  • Responsivity: 40.8
  • Operating Temperature: 437
Thin Film Based Thermopile Detector -- 1M
from Dexter Research Center, Inc.

Features: A thin film-based thermopile with a 1.0mm diameter active area with good signal-to-noise ratio in a TO-5 package and a moderate time constant of 32ms with Argon encapsulation gas. Applications: Excellent for non-contact temperature measurement. Benefit: Small active area with good... [See More]

  • Electrical Output: Voltage
  • Detectivity: 2.1 to 4.8
  • Responsivity: 19.3 to 30.9
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- 1SC
from Dexter Research Center, Inc.

Features: A thin film-based single channel thermopile detector that offers thermal compensation to minimize effects of sudden ambient temperature change during the initial five seconds of change. The 1SC Compensated comes in a TO-5 package with a medium sized 1.0 x 1.0mm active area. Compensation is... [See More]

  • Electrical Output: Voltage
  • Detectivity: 0.8000 to 1.4
  • Responsivity: 12.1 to 16.7
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- 2M
from Dexter Research Center, Inc.

Features: A thin film-based single element thermopile detector that offers the world ™s highest sensitivity in a TO-5 package. Dare to compare. Low noise voltage of 12.8nV/ ˆ šHz. Applications: Excellent for gas analysis, fire detection and non-contact temperature measurement. [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.9 to 5
  • Responsivity: 15.2 to 22.7
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- DR34
from Dexter Research Center, Inc.

Features: A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity. Applications: Industrial and medical monitoring including... [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.2 to 3.1
  • Responsivity: 21.6 to 31.2
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- DR46
from Dexter Research Center, Inc.

Features: A two-channel or a one-channel compensated thin-film thermopile in a TO-8 package. Each active area is 4mm x 0.6mm. Offers high output with excellent signal-to-noise ratio. An internal aperture minimizes channel-to-channel crosstalk increasing sensitivity. Applications: Gas analysis,... [See More]

  • Electrical Output: Voltage
  • Detectivity: 2.1 to 4.6
  • Responsivity: 21.5 to 31.6
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- DR46 Compensated
from Dexter Research Center, Inc.

Features: A one-channel compensated thin-film thermopile in a TO-8 package. The active area and compensating element area are 4mm x 0.6mm each. Offers high output with very good signal-to-noise ratio. Internal aperture minimizes channel-to-channel crosstalk increasing sensitivity. Applications:... [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.5 to 3.2
  • Responsivity: 21.5 to 31.6
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- M14
from Dexter Research Center, Inc.

Features: A single-channel thin film-based thermopile offering very low noise in a compact TO-18 package with a small active area of 0.92mm x 0.4mm. This is one of the lowest noise thermopiles you can buy and provides a fast 14ms time constant with Argon encapsulation gas. Applications: Excellent... [See More]

  • Electrical Output: Voltage
  • Detectivity: 0.9300 to 2.5
  • Responsivity: 12.4 to 20.6
  • Operating Temperature: -58 to 212
Thin Film Based Thermopile Detector -- M34
from Dexter Research Center, Inc.

Features: A thin-film thermopile in a TO-5 package with an active area of 3.16mm x 0.4mm that offers low noise output. Applications: Non-contact temperature measurement for industrial and medical, including infant incubators. Benefit: Centered rectangular active area and low noise with moderate... [See More]

  • Electrical Output: Voltage
  • Detectivity: 1.7 to 4.3
  • Responsivity: 4 to 12
  • Operating Temperature: -58 to 212
Adjustable IRt/c -- IRt/c.100A-*-HiE
from Exergen Corp.

These models allow for the user to calibrate the IRt/c's to match a thermocouple in whatever temperature range they desire. The range adjustment screw is adjusted to calibrate for temperature range of interest and material properties (emissivity). Models for non-metals (HiE) and metals (LoE) are... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 2 to 20
  • Temperature Range: 1000 to 5000
  • Ratio: Distance / Spot Size: 100
Self-Calibrating Soil Heat Flux Plate -- HFP01SC-L
from Campbell Scientific, Inc.

The HFP01SC measures heat flux, typically as a component within energy balance or Bowen ratio flux systems. The HFP01SC is manufactured for Campbell Scientific by Hukseflux (Delft, The Netherlands). The sensor outputs a voltage signal that is proportional to the heat flux of the surrounding medium. [See More]

  • Electrical Output: Voltage
  • % of Reading: -3 to 3
  • Temperature Range: -22 to 158
  • Operating Temperature: -22 to 158
Adjustable IRt/c -- IRt/c.10A-*-HiE
from Exergen Corp.

These models allow for the user to calibrate the IRt/c's to match a thermocouple in whatever temperature range they desire. The range adjustment screw is adjusted to calibrate for temperature range of interest and material properties (emissivity). Models for non-metals (HiE) and metals (LoE) are... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 2 to 20
  • Temperature Range: -50 to 2500
  • Ratio: Distance / Spot Size: 10
Soil Heat Flux Plate -- HFP01-L
from Campbell Scientific, Inc.

The HFP01 provides soil heat flux measurements —typically for energy balance or Bowen ratio flux systems. It outputs a voltage signal that is proportional to the heat flux of the surrounding medium. At least, two sensors are required for each site to provide spatial averaging. Sites with... [See More]

  • Electrical Output: Voltage
  • % of Reading: -15 to 5
  • Temperature Range: -22 to 158
  • Operating Temperature: -22 to 158
Adjustable IRt/c -- IRt/c.12AMF-*-LoE
from Exergen Corp.

These models allow for the user to calibrate the IRt/c's to match a thermocouple in whatever temperature range they desire. The range adjustment screw is adjusted to calibrate for temperature range of interest and material properties (emissivity). Models for non-metals (HiE) and metals (LoE) are... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 0.1000 to 5
  • Temperature Range: 400 to 2500
Adjustable IRt/c -- IRt/c.2/15ACF-*-HiE
from Exergen Corp.

These models allow for the user to calibrate the IRt/c's to match a thermocouple in whatever temperature range they desire. The range adjustment screw is adjusted to calibrate for temperature range of interest and material properties (emissivity). Models for non-metals (HiE) and metals (LoE) are... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 2 to 20
  • Temperature Range: 0 to 2500
Adjustable IRt/c -- IRt/c.2/15ALF-*-HiE
from Exergen Corp.

These models allow for the user to calibrate the IRt/c's to match a thermocouple in whatever temperature range they desire. The range adjustment screw is adjusted to calibrate for temperature range of interest and material properties (emissivity). Models for non-metals (HiE) and metals (LoE) are... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 2 to 20
  • Temperature Range: 700 to 3000
Linearized Infrared Temperature Sensor -- SmartIRt/c.20
from Exergen Corp.

Plug and play, linearized, precise accuracy, with integral design which eliminates thermal drift. No leakage current, impedance, or cold junction compensation to worry about. [See More]

  • Electrical Output: Current; Voltage; Serial
  • % of Reading: 1.5
  • Temperature Range: 0 to 500
  • Spectral Range: 5.5 to 20
Pre-Calibrated IRt/c -- IRt/c
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 1200
  • Ratio: Distance / Spot Size: 1
Pre-Calibrated IRt/c -- IRt/c.01
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 550
  • Ratio: Distance / Spot Size: 1
Pre-Calibrated IRt/c -- IRt/c.03
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 550
  • Ratio: Distance / Spot Size: 3
Pre-Calibrated IRt/c -- IRt/c.1X
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 1200
  • Ratio: Distance / Spot Size: 1
Pre-Calibrated IRt/c -- IRt/c.2
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Temperature Range: -50 to 2000
Pre-Calibrated IRt/c -- IRt/c.3SV
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 1200
  • Ratio: Distance / Spot Size: 3
Pre-Calibrated IRt/c -- IRt/c.3X
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 1200
  • Ratio: Distance / Spot Size: 3
Pre-Calibrated IRt/c -- IRt/c.5
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 1200
  • Ratio: Distance / Spot Size: 5
Pre-Calibrated IRt/c -- IRt/c.SV
from Exergen Corp.

The most reliable non contact temperature sensors on earth. No active electronics, so these passive devices can not fail. Mean Time Between Failure reports have been documented with a rate of > 1,000 years between failures. The patented technology separates the IRt/c from all other non contact... [See More]

  • Electrical Output: Voltage
  • Spectral Range: 6.5 to 14
  • Temperature Range: -50 to 1200
  • Ratio: Distance / Spot Size: 1
Pre-Calibrated IRt/c -- micro IRt/c-K
from Exergen Corp.

The world's smallest IRt/c's are self powered, with K t/c output. For those special applications where mounting is impossible with standard sized sensors, the micro IRt/c can go places no other IR sensors have gone before, with the same high performance as all of the IRt/c products. [See More]

  • Electrical Output: Voltage
  • Spectral Range: 5.5 to 20
  • Temperature Range: 0 to 975
  • Response Time: 50