Supplier: Panel Components & Systems, Inc.
Description: AVR 5-120 Voltage Regulator is an electronic device which lets the alternator produce a fixed output voltage. The AVR 5-120 is a 120V,AC model. It has an open chassis, resin molded design and is intended to be mounted in the alternator’s terminal box. AVR 5-120 measures
-
Supplier: Panel Components & Systems, Inc.
Description: AVR 12-120 Voltage Regulator is an electronic device which lets the alternator produce a fixed output voltage. The AVR 12-120 is a 120V,AC model. It has an open chassis, resin molded design and is intended to be mounted in the alternator’s terminal box. AVR 12-120
-
Supplier: Panel Components & Systems, Inc.
Description: AVR 12-120 Voltage Regulator is an electronic device which lets the alternator produce a fixed output voltage. The AVR 12-120 is a 120V,AC model. It has an open chassis, resin molded design and is intended to be mounted in the alternator’s terminal box. AVR 12-120
-
-
Supplier: Infineon Technologies AG
Description: TLE8881TN regulates 12V automotive multi-phase alternators and is compliant to the HKMC LIN Alternator Regulator specification The alternator control IC TLE8881TN is a monolithic full featured regulator specifically designed for closed loop voltage control.
-
Supplier: Infineon Technologies AG
Description: TLE8881-2TN regulates 12V automotive multi-phase alternators The alternator control IC TLE8881-2TN is a monolithic full featured regulator specifically designed for closed loop voltage control. It can be used in 12V automotive multi-phase alternators with a
-
Supplier: Infineon Technologies AG
Description: TLE8886TN regulates 12V automotive multi-phase alternators with a rotating field winding The alternator control IC TLE8886TN is a monolithic full featured regulator specifically designed for closed loop voltage control. It can be used in 12V automotive multi-phase
-
Supplier: Infineon Technologies AG
Description: TLE8880TN2 regulates 12V automotive multi-phase alternators with a rotating field winding The alternator control IC TLE8880TN2 is a monolithic full featured regulator specifically designed for closed loop voltage control which can be used in 12V automotive
-
Supplier: Lingto Electronic Limited
Description: ALTERNATOR REGULATOR, 14V 12A, L
- Regulator Category: Other
-
Description: ALTERNATOR REGULATOR, 14V 12A, L
-
Supplier: Electric Generators Direct
Description: rack & cables Cast Iron Cylinder Liner w/ Low Oil Pressure Shutdown •Provides added protection Automatic Voltage Regulator •Prevents equipment damage & power related performance problems 18-Gallon Fuel Tank Provides Extended Run Time •11.5 hours
- Applications: Industrial, Power
- Frequency: 60 Hz
- Fuel Type: Gasoline
- Phase: AC Three Phase Power
-
Supplier: SAE International
Description: control systems in internal combustion engine road vehicles. This document is not intended to include nor exclude regulators used in higher voltage vehicle electrical systems. The term "generator" rather than "alternator" will be used even though these terms may be used interchangeably
-
Supplier: Central Marine Diesel
Description: alternators with THD less than 6%. The D4500E generator is equipped with an automatic voltage regulator for clean power, wheel kit, voltmeter, main line circuit breaker, frame mounted control panel, large metal fuel tank w/ chrome cap, battery rack and cables and is electric start.
- Fuel Type: Diesel
- Voltage: 120 V, 240 V
- Wattage: 3500 watts
-
Supplier: Central Marine Diesel
Description: features brushless HD alternators with THD less than 6%. The D4500E generator is equipped with a sound proof enclosure, automatic voltage regulator for clean power, wheel kit, voltmeter, main line circuit breaker, glow plugs for cold weather starting, frame mounted control panel, large
- Fuel Type: Diesel
- Voltage: 120 V, 240 V
- Wattage: 3500 watts
-
Supplier: Electric Generators Direct
Description: rack & cables Cast Iron Cylinder Liner w/ Low Oil Pressure Shutdown •Provides added protection Automatic Voltage Regulator •Prevents equipment damage & power related performance problems 18-Gallon Fuel Tank Provides Extended Run Time •11.5 hours
- Applications: Industrial, Power
- Frequency: 60 Hz
- Fuel Type: Gasoline
- Phase: AC Three Phase Power
-
Supplier: Electric Generators Direct
Description: Tri-Fuel Carburetor and Gas Regulator •Versitile generator runs on LP gas, natural gas or gasoline 20-HP Electric Start Honda GX Series V-Twin Engine •Premium-quality, fuel-efficient engine with low oil protection •Standard electric start w/ battery rack and
- Frequency: 60 Hz
- Fuel Type: Gasoline, Propane, Natural Gas
- Phase: AC Single Phase Power
- Voltage: 120/240 V
-
Supplier: Electric Generators Direct
Description: outage 1800 RPM Brushless Alternator w/ Automatic Voltage Regulator •Produces clean and safe electricity for sensitive electronics Frequency Meter & Circuit Breakers •Monitor and protect your generator and tools Standard 1-3/8” Six Spline w/ Helical Gears
- Applications: Power
- Frequency: 60 Hz
- Phase: AC Single Phase Power
- Voltage: 120/240 V
-
Supplier: Central Marine Diesel
Description: OHV engine w/ a cast-iron cylinder liner for longer life and brushless HD alternators with automatic voltage regulator to protect sensitive electronics. This genset is equipped with Smart Throttle™ that will vary engine speed with load demand, inverter system with Pulse Width
- Fuel Type: Gasoline, Natural Gas, Other
- Voltage: 120 V
- Wattage: 2000 watts
-
Supplier: Central Marine Diesel
Description: the box! No mechanical alterations necessary! Simply change your fuel source! This unit features a premium 357cc Yamaha OHV engine w/ a cast-iron cylinder liner for longer life and brushless HD alternators with automatic voltage regulator to protect sensitive electronics. This genset
- Fuel Type: Gasoline, Natural Gas, Other
- Voltage: 120 V
- Wattage: 4000 watts
-
Supplier: Littelfuse, Inc.
Description: alternator rating. Most alternators on new vehicles have an integral electronic voltage regulator that requires the use of the 4-stud battery isolator. The small 4th stud is for connection to a circuit switched by the ignition switch. The newer alternators were first
- Maximum Current: 250 amps
-
Supplier: Littelfuse, Inc.
Description: alternator rating. Most alternators on new vehicles have an integral electronic voltage regulator that requires the use of the 4-stud battery isolator. The small 4th stud is for connection to a circuit switched by the ignition switch. The newer alternators were first
- Maximum Current: 90 amps
-
Supplier: Littelfuse, Inc.
Description: alternator rating. Most alternators on new vehicles have an integral electronic voltage regulator that requires the use of the 4-stud battery isolator. The small 4th stud is for connection to a circuit switched by the ignition switch. The newer alternators were first
- Maximum Current: 140 amps
-
Supplier: Littelfuse, Inc.
Description: alternator rating. Most alternators on new vehicles have an integral electronic voltage regulator that requires the use of the 4-stud battery isolator. The small 4th stud is for connection to a circuit switched by the ignition switch. The newer alternators were first
- Maximum Current: 70 amps
-
Supplier: Caterpillar Oil & Gas
Description: sump Oil filler and dipstick Protection System The following parameters include alarm and shutdown G3306B Optional Equipment Charging Alternator 24V, 35A alternator 24V, 35A
- Application: Industrial
- Displacement: 10.45 liters
- Engine Type: Internal Combustion
- Fuel Type: CNG
-
Supplier: Caterpillar Oil & Gas
Description: and dipstick Protection System The following parameters include alarm and shutdown G3304B Optional Equipment Charging Alternator 24V, 35A alternator 24V, 35A CSA alternator
- Application: Industrial
- Displacement: 7 liters
- Engine Type: Internal Combustion
- Fuel Type: CNG
-
Supplier: Microchip Technology, Inc.
Description: control the output current with high accuracy. The IC includes a +/-1A gate driver that makes the AT9917 suitable for high power applications. An internal 40V linear regulator powers the IC eliminating the need for a separate power supply for the IC. The IC provides a FAULT output,
- Features: RoHS Compliant
- Form Factor: Integrated Circuit (IC)
- Input Voltage: 5.3 to 40 volts
- Type: Dimmable
-
Supplier: Caterpillar Oil & Gas
Description: pulleys Protection System Air shutoff Starting System Air starting motors Air pressure regulator Air silencer Start switch Electric starting motors — 12V, 24V
- Application: Industrial
- Displacement: 18.03 liters
- Engine Type: Internal Combustion
- Features: EPA Certified, EU Certified, EPA Tier 3/EU Stage IIIA
-
Supplier: Caterpillar Oil & Gas
Description: Cylinder block inspection covers CG137-8 Optional Equipment Charging Alternator 24V, 60A CSA alternator Exhaust System Exhaust flex fitting Exhaust elbow Exhaust
- Application: Industrial
- Displacement: 18.01 liters
- Engine Type: Internal Combustion
- Fuel Type: CNG
Find Suppliers by Category Top
More Information Top
-
Exercise bike powered electric generator for fitness club appliances
… with a channel, the generator pulley is at 5cm diameter; ii) generator: 750W and 12VDC auto- alternator with voltage regulator (limits amount of current … … 1, 5]; iii) 12 V and 120Ah lead-acid … … 24VDC loads and indirectly 48 VDC loads as well …
-
1979 Index IEEE Transactions on Industrial Electronics and Control Instrumentation Vol. IECI-26
… Charles K; T-IECI v26 n4 Nov 79 218-226 (1B02) Switching regulators ; cf. Power conversion, dc … … brushless excitation system for alternator using shaft-mounted thyristors … … fully controlled converters; Subbiah, V .; T-IECI v26 n] Feb 79 48 -50 (ID08) ON/OFF detection …
-
CR4 - Thread: 12V Alternator Conversion
Whatever you do you need to get a alternator that utilizes a external voltage regulator to be able to control the output. One possible wiring scheme would be to read the voltage from a single 12 volt battery in your 48 V battery pack, while still charging in series , probably some drawbacks to that but it just could work.
-
1979-1980 Conference Index
… frequency filters; Schwarz, Francisc C.; PESC 79 448-458 single-phase controlled rectifier bridges; improved power factor through modified gating; Dewan, S. B.; PESC 80 357-365 superconducting alternator with rectified output; parameter … … source inverters; Jones, D. V .; PESC 79 234-235 … … 80 Vol 2 1401-1405 multioutput Cuk converter; modeling and analysis; Bloom, G. E.; PESC 80 33-47 multioutput dc-dc converters; cross-noise; Ninomiya, Tamotsu; PESC 80 48 -56 multiple output converter … … 185 multiple output switching regulators using cross-regulation; steady …
-
Displays for future intermediate UAV
Each of the three phases would have a Transient Voltage Suppressor (TVS) to mitigate voltage spikes from the alternator , up to 48V . … intended to run even if the TVS burned out, as long as the regulators themselves did not.
-
http://dspace.mit.edu/bitstream/handle/1721.1/86733/49317016-MIT.pdf?sequence=2
48 Because the donated alternator is a 40 V alternator, it needed to be converted into a 42V alternator in order to be used in the 42V-14V dual-voltage automobile electrical system. In order to do this, the regulator from the Bosch alternator was removed and the voltage sensing …
-
Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1994--31 August 1995
During the first five months of 1995, this accelerator operated for 48 % of the available time. This singleended Vande GraafE operated at terminal potentials ranging from 0.99 M V to 3.51 … Repairs included three ion source changes, replacement of the charging belt, two replace- ments of the focus power supply, two replacements of the corona regulator needles,three drive motor and/or alternator bearing changes, installation of a new drivemotor (on indefi- nite loan …
-
Energy: Resources, technologies and the environment
Commonly used voltages are 12, 24 and 48 V , which require several cells to be connected in series. A PV system comprises a rigid structure to support the modules, cables, a battery and its charge regulator if electrical energy is being stored and an alternator when feeding equipment using alternating current.
-
A novel power generation system for ground vehicles
The new system consists of a permanent magnet (PM) alternator , a split winding and a novel electronic voltage regulator . Analysis show that a 48V system would be even more efficient with up to 5- percentile points improvement and could use power devices with reduced current rating, size and cost.
-
Panhard Defense M3 armoured personnel carrier
All new electrical components include more reliable electrical wire bundles, electric voltage regulator , 24 V 65 A generator, 24 V starter, new drivers panel and new instrumental panel. … 5.5 3.4 on 10 per cent gradient on 60 per cent gradient creep water 4 2.5 Acceleration from 0 to 32 km/h from 0 to 48 km/h from 0 to … … Batteries 2 × 12 Alternator × Generator × Firepower …
Indicates content that may require registration and/or purchase.