-
Supplier: ValueTronics International, Inc.
Description: ) Versatile analysis (temperature, cole-cole plot, relaxation time) Sweep parameters (frequency, AC level, DC bias, temperature) The Agilent 4291B RF impedance/material analyzer provides a total solution for high-accuracy and easy measurement of surface
-
Supplier: ValueTronics International, Inc.
Description: /2-digits Internal ±40 VDC bias HP-IB The Agilent HP 4191A RF Impedance Analyzer measure 14 parameters with a maximum resolution of 4.5 digits. The internal synthesizer provides variable frequencies from 1 MHz through 1000 MHz covering the UHF, VHF, and video bands
-
Supplier: ValueTronics International, Inc.
Description: -Phase measurements include amplitude, phase, and group delay Impedance measurements include |Z|, |Y|, phase, R, X, G, B, Cp, Cs, Lp, Ls, Rp, Rs, D, Q DC bias to ±35 V GPIB The HP 4291A RF impedance/material analyzer provides a total solution for high
-
-
Supplier: ValueTronics International, Inc.
Description: RF impedance/material analyzer offers ultimate impedance measurement performance and powerful built in analysis function. It will provide innovations in R&D of components and circuit designers who evaluate components in the range of 3 GHz. The Keysight Agilent HP E4991A
-
Supplier: Rohde & Schwarz USA, Inc.
Description: speed R&S®ZNB40 two-port model available in two versions Convenient characterization of active and passive RF components Fast embedding/de-embeddi ng for impedance matching using virtual networks Mixed-mode S-parameters for balanced DUT
- Display Options: Video Display
- Frequency Range: 9 to 4.00E7 kHz
- Instrument Type: Portable / Benchtop Instrument
-
Supplier: Fairview Microwave Inc.
Description: RF cable assembly part number FMCA1411-60 rugged portable phase stable RF analyzer cable N male to TNC female cable FM-FT430 coax in 60 and RoHS from Fairview Microwave is one of a huge selection of coaxial cables for radio, antenna and interconnect with RF components.
- Application: RF
- Cable Length: 5 ft
- Connector Type: Other
-
Supplier: Fairview Microwave Inc.
Description: RF cable assembly part number FMCA1408-60 rugged portable phase stable RF analyzer cable N male to SMA male cable FM-FT430 coax in 60 and RoHS from Fairview Microwave is one of a huge selection of coaxial cables for radio, antenna and interconnect with RF components.
- Application: RF
- Cable Length: 5 ft
- Connector Type: Other
-
Supplier: Fairview Microwave Inc.
Description: RF cable assembly part number FMCA1402-144 rugged portable phase stable RF analyzer cable N male to N male cable FM-FT430 coax in 144 and RoHS from Fairview Microwave is one of a huge selection of coaxial cables for radio, antenna and interconnect with RF components.
- Application: RF
- Cable Length: 12 ft
- Connector Type: Other
-
Supplier: Fairview Microwave Inc.
Description: RF cable assembly part number FMCA1405-100CM rugged portable phase stable RF analyzer cable N male to N male cable FM-FT430 coax in 39.37 and RoHS from Fairview Microwave is one of a huge selection of coaxial cables for radio, antenna and interconnect with RF components.
- Application: RF
- Cable Length: 3.28 ft
- Connector Type: Other
-
Supplier: Pasternack
Description: Radio frequency assembly handheld RF analyzer rugged phase stable cable N male to N female cable 144 inch length using PE-FF430 coax, RoHS from Pasternack is part of the largest selections of same-day ship coaxial cables for RF, microwave and millimeter wave interconnect
- Application: RF
- Cable Length: 12 ft
- Standards: RoHS
-
Supplier: Pasternack
Description: Radio frequency assembly handheld RF analyzer rugged phase stable cable N male to TNC male cable 60 inch length using PE-FF430 coax, RoHS from Pasternack is part of the largest selections of same-day ship coaxial cables for RF, microwave and millimeter wave interconnect
- Application: RF
- Cable Length: 5 ft
- Standards: RoHS
-
Supplier: Pasternack
Description: Radio frequency assembly handheld RF analyzer rugged phase stable cable N male to N female cable 60 inch length using PE-FF430 coax, RoHS from Pasternack is part of the largest selections of same-day ship coaxial cables for RF, microwave and millimeter wave interconnect
- Application: RF
- Cable Length: 5 ft
- Standards: RoHS
-
Supplier: Pasternack
Description: Radio frequency assembly handheld RF analyzer rugged phase stable cable N male to SMA female cable 60 inch length using PE-FF430 coax, RoHS from Pasternack is part of the largest selections of same-day ship coaxial cables for RF, microwave and millimeter wave interconnect
- Application: RF
- Cable Length: 5 ft
- Standards: RoHS
-
Supplier: Siglent Technologies NA, Inc.
Description: SSM5000A series switch matrix can expand the number of test ports of network analyzer, signal source, spectrum analyzer and other equipment. And the series are with up to 4 input ports and up to 24 output ports, supporting USB, LAN, Direct Control communication modes. The Direct
-
Supplier: QuinStar Technology, Inc.
Description: useful for power detection, monitoring, built-in-test and frequency measurement. The detectors can also be used in millimeter-wave test systems with a wide variety of high-impedance oscilloscopes and scalar analyzers. They can be used for both CW and pulsed power measurements. They are
- Input Frequency Range: 18000 to 170000 MHz
- Package Type: Connectorized
- Power Level: 16.99 to 20 dBm
- RF Connector: SMA
-
Supplier: Copper Mountain Technologies
Description: human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections
- Application Software Included: Yes
- Calibrator Style: Modular, Other Specific Calibration?
- Computer Interface: Yes
- DC Voltage: Yes
-
Supplier: RS Components, Ltd.
Description: . Custom plastic RF-optimized for precise measurements. RF coating for best possible paint absorption and durability. RF-optimized paint for the lowest possible damping. Device mount for stable attachment of a spectrum analyzer. SMA connector Accessory Type = Broadband
-
Supplier: A.H. Systems Inc.
Description: current probe is clamped around the center conductor. The fixture's output terminal is terminated in a 50 ohm receiver, spectrum analyzer or RF voltmeter. A measurement of the voltage developed by this RF voltmeter permits the calculation of current flowing in the center
- Current Type: AC Current
- Frequency Range: 20 to 5.00E8 Hz
- Mounting / Configuration: Clamp or Bolt On
-
Supplier: RS Components, Ltd.
Description: -5812 ) come with voltage-controlled crystal oscillator (VCXO). The TSG4100A instruments complement other leading mid-range RF test solutions from Tektronix such as the USB-based RSA306 spectrum analyzer ( 830-2852 ) and the Tektronix MDO4000B and MDO3000 mixed domain oscilloscopes.
- Generator Type: Function
- Minimum Frequency Range: 0.9500 to 2000 MHz
-
Supplier: Teledyne LeCroy
Description: rates of up to 10 MHz and uses the same open short load (OSL) calibration standards as vector network analyzers. Thanks to their small form factors, light weight, and optional internal batteries, the instruments go anywhere in test labs or in the field at a cost-effective price point. Key
- Form Factor: Portable / Hand Held / Mobile
Find Suppliers by Category Top
Featured Products Top
-
The ShockLine MS46524B series raises the bar for performance and value in 4-port vector network analyzers (VNAs). This series excels in testing multiport devices up to 43.5 GHz, making it perfect for applications like: Development and production of multiport equipment for 5G (28 GHz (read more)
Browse Vector Network Analyzers Datasheets for Anritsu Company -
Smart Use Of Preamps In RF Testing Any type of radio frequency (RF) testing requires antennas. Equipment under test may or may not have them - some devices aren't designed to broadcast but still might. But the analyzer will always require an antenna to receive whatever signal there might be (read more)
Browse RF Amplifiers Datasheets for A.H. Systems Inc. -
possible sources of error, and improve mechanical stability compared with using a cable plus multiple intermediate adapters. The SMS-200-48.0-NMS has a 50 ohm impedance, which is the standard impedance for many RF and microwave systems. Maintaining a 50 ohm signal path is important when (read more)
Browse Circuit Protection Components Datasheets for ERSAELECTRONICS PTE. LTD. -
instruments, microwave components, antennas, test fixtures, evaluation boards, signal generators, spectrum analyzers, network analyzers, amplifiers, attenuators, filters, switches, couplers, and other RF modules. Its SMA male straight plug connectors on both ends allow it to mate with many standard SMA (read more)
Browse Circuit Protection Components Datasheets for ERSAELECTRONICS PTE. LTD. -
can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on current probes. The BCP-615 Current Probe is designed to permit field intensity meters, spectrum analyzers, and other 50 ohm impedance instruments to measure quantitative magnitudes of (read more)
Browse Current Sensors Datasheets for A.H. Systems Inc. -
: Provides critical isolation in tactical radios, radar, and electronic warfare equipment. ·Public Safety Networks: Supports reliable operation in emergency communication systems. ·Test & Measurement: Safeguards signal sources and analyzers during RF testing (read more)
Browse RF Isolators and RF Circulators Datasheets for 5o.com -
polarization (polarity). 3)Connect the output of the receiving antenna to the input of the receiving system (spectrum analyzer used to measure field), using a low VSWR, low loss coaxial cable. The input impedance for the receiving system, and the receiving antenna should all be matched to 50W (read more)
Browse Antennas Datasheets for A.H. Systems Inc. -
some automotive and military testing commonly involve higher levels of RF fields that deliver a signal already above the noise floor. In such cases, you can connect the receiving antenna directly to the signal analyzer. Working with preamps in testing When using a preamp in (read more)
Browse RF Amplifiers Datasheets for A.H. Systems Inc. -
Connections in RF testing Almost every RF test setup requires connectors and cables. Connectors will influence test results in various and sometimes unpredictable ways. Test equipment can (read more)
Browse Coaxial Cables and Triaxial Cables Datasheets for A.H. Systems Inc.
More Information Top
-
Thermal Analysis of Polymers Fundamentals and Applications Complete Document
The network or radiofrequency ( RF ) impedance analyzers , with an operational frequency range from 1 MHz to ∼10 GHz and tan δ > 3 × 10−3, use the transmission/reflection technique and are convenient for dielectric materials with sufficient relaxation strength, as well as relatively …
-
Dielectric imaging and its frequency dependence of dielectric device using non-contact state microwave probe
The measured frequency dependence of dielectric permittivity and dielectric loss for multi - layer ceramics capacitor were accordance with the low frequency dielectric spectra measured by a RF impedance analyzer .
-
In-plane dielectric characterization of sol–gel derived PLZT (9/65/35) thin films using an interdigital electrode configuration
The dielectric properties as a function of frequency were measured using a HP 4292 A precision impedance analyzer (1 kHz–1 MHz), a HP4291B RF impedance analyzer (1–500 MHz .
-
Laboratory Measurement of Dielectric Constant Near 20 MHz
It consists of a sample cell, a cell holder, an RF impedance analyzer , and a computer with peripherals.
-
RF / Analyzers
TE1000/TE3000/TE3001 - VECTOR RF IMPEDANCE ANALYZERS .
-
RF / Vector
TE1000/TE3000/TE3001 - VECTOR RF IMPEDANCE ANALYZERS .
-
RF / Impedance / Impedance Analyzers
TE1000/TE3000/TE3001 - VECTOR RF IMPEDANCE ANALYZERS .
-
Impedance Analyzer
TE1000/TE3000/TE3001 - VECTOR RF IMPEDANCE ANALYZERS .
-
RF Analyzer
TE1000/TE3000/TE3001 - VECTOR RF IMPEDANCE ANALYZERS .
-
Radial Pulse Propagation And Impedance Characteristics Of Optically Shuttered Channel Intensifier Tubes
Cm, Rm = data measured with LCR meter CA, RA = data measured with automatic network analyzer CZ, RZ = data measured with rf impedance analyzer .
Indicates content that may require registration and/or purchase.