-
Supplier: Process Sensing Technologies USA
Description: A robust, linear and stable thermal conductivity analyzer for measurement of binary gas mixes such as air in hydrogen, nitrogen, argon, helium or carbon-dioxide. The sensor is housed in a rugged casing, making it suitable for a wide range of applications. The analyzer can
- Operating Temperature: 32 to 104 F
- Measurement Type: %Volume
- Instrument Type: Analyzer, Monitor
- Features: Self Calibration
-
Supplier: Process Sensing Technologies USA
Description: The XZR400 zirconium oxide gas purity analyzer from Michell Instruments is designed to measure oxygen as an impurity in inert gases such as nitrogen, carbon dioxide, helium and argon. A range of trace oxygen analyzers utilizing Michell's Metallic Sealed Reference Sensor
- Operating Temperature: 32 to 131 F
- Operating Humidity: 5 to 90 %
- Instrument Type: Analyzer
- Features: Self Calibration
-
Supplier: Process Sensing Technologies USA
Description: The LD8000 is an online analyzer to monitor trace N2 in Ar/He/Crude Argon. A plasma emission detector is used to selectively measure trace N2 in pure Argon or/and Helium bulk gases as well as Argon containing up to 5% O2. The analysis of trace N2 in Neon, Xenon and
- Operating Temperature: 50 to 113 F
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
-
Supplier: Process Sensing Technologies USA
Description: range: 0 to 25% O2 Compact ambient oxygen monitor Audio/ visual alarm indicator LCD + 4 button multifunction keypad Simple Installation (only power lead required)Applications: Gas generation (oxygen / nitrogen) Industrial Gas Users Laboratories with Gas Chromatographs
- Operating Humidity: 0 %
- Measurement Type: %Volume
- Instrument Type: Analyzer
- Application: Process Gas
-
Supplier: Quantachrome Instruments
Description: and reliable method for extremely rapid and accurate B.E.T. surface area measurements, doesn't require void volume measurements and ideal gas corrections. The high degree of sensitivity of the Monosorb allows the use of samples weighing less than 1g and provides the measurement of surface
- Display & Special Features: Digital Readout, Laboratory / Batch
- Features: Other
- Sample Type: Powder / Solid Particles
- Measurement Type: Size
-
Supplier: CO2Meter.com
Description: The TecPen Oxygen and Carbon Dioxide Weld Purge Monitor is designed to provide accurate measurements down to 0% oxygen and up to 100% carbon dioxide when back purging with argon and CO2 gas mix during welding. This portable O2 and CO2 analyzer will verify that
- Measurement Type: %Volume
- Gas Types: Carbon Dioxide (CO2), Oxygen (O2)
- Features: Other
- Number of Gases Monitored: Single Gas
-
Supplier: ASTM International
Description: 1.1 This test method covers procedures for the use of oxygen analyzers to measure the percentage of oxygen in an insulating glass unit where normal atmospheric air has been replaced with other gases such as argon, krypton, xenon, or sulfur hexafluoride (SF6). The procedure shows how to
-
Supplier: ASTM International
Description: This method is for determining the composition of refinery gas streams or vaporized liquefied petroleum gas (LPG) using a preconfigured, commercially available gas chromatograph. At a minimum, the following components are reported: non-condensable gases, individual C1 through C4
-
Supplier: ASTM International
Description: process unit sources as well as in the sample introduction into the analyzer in the laboratory. 1.5 Water vapor may interfere with the C6+ analysis if a TCD detector is used. 1.6 Helium and argon may interfere with the determination of hydrogen and oxygen respectively. Depending on the
-
Supplier: GasLab
Description: from factory Data logging with USB transfer Industry Applications Include: TIG welding of stainless steel or titanium Argon gas purging for pipe welding 3D Printing under oxygen exclusion Models TS-300 - TecPen Weld Purge Monitor & welding oxygen analyzer. Specifications
-
Supplier: ASTM International
Description: preferred diluent gas shall be the same as the carrier gas used in the RGA (typically helium or argon). Choice of diluent or carrier gas may affect the ability to detect some inert gases (especially O2 or H2) in some RGA configurations conforming to Test Method D7833. 1.5
Find Suppliers by Category Top
Featured Products Top
-
The Palm CO Analyzer is a compact, portable instrument designed to detect carbon monoxide contamination in breathing air and compressed gas systems. It provides fast, reliable CO measurement to help prevent exposure to dangerous carbon monoxide levels (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
industry expertise and relationships that have cemented CO2Meter as a true "go-to-source" for customers and partners. Their technologies encompass a wide range of product categories from fixed gas detectors, portable gas analyzers, and gas controllers that are installed and used widespread across the (read more)
Browse Gas Instruments Datasheets for CO2Meter.com -
CO2Meter Inc., a worldwide leader in gas detection and safety monitoring, released its new portable CO2 welding gas analyzer that verifies correct CO2 concentrations in welding gas mixes. The highly anticipated CM-1650 measures mixed cylinder gas or blended gas at a mixer to ensure the (read more)
Browse Data Loggers and Data Recorders Datasheets for CO2Meter.com -
ensures the proper handling and storage of flammable gases, vapor, and liquids to prevent ignition. With the GM32 in-situ gas analyzer now certified with this approval, this ensures the effective and safe measurement of SO2, NO, NO2, and (read more)
Browse Gas Instruments Datasheets for SICK -
The revolutionary analyzer for natural gas quality monitoring We are pleased to announce the launch of our new Sensi+, the single and compact analyzer that detects simultaneously multiple gas contaminants in natural gas stream. It provides continuous measurements of H2S (read more)
Browse Gas Instruments Datasheets for ABB Measurement & Analytics -
Semiconductor manufacturing is a complex and specialized process with numerous applications for precision gas and pressure control. Learn more about how Clippard's engineering team combined our DR-2 regulator and analytical valve with a special manifold to create a precision flow (read more)
Browse Gas Valves Datasheets for Clippard -
commissioning and maintenance as the set points and dead bands are field programmable, saving more than 70% in maintenance time compared to a mechanical switch. The 1XSWLL model operates on the same 2 wires as a mechanical switch enabling (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
minimal commissioning and maintenance as the set points and dead bands are field programmable, saving more than 70% in maintenance time compared to a mechanical switch. The 1XSWLL model operates on the same 2 wires as a mechanical switch enabling (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
AII’s portable O? analyzer range provides accurate oxygen measurement in a variety of portable and field-based applications. Designed for ease of use and dependable performance, these analyzers support oxygen verification wherever mobility is required (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
A Quick Guide to Calibrating CEM Gas Analyzers Calibrating Continuous Emissions Monitoring (read more)
Browse Manifolds and Manifold Systems Datasheets for Environics, Inc.
More Information Top
-
Exhaled breath condensate pH standardised for CO2 partial pressure.
Condensate pH and CO2 partial pressure were measured in parallel from 12 healthy volunteers and 12 asthmatics using a blood gas analyser in neat, argon de-aerated and CO2 -loaded samples.
-
Instrument Selection For the Characterization of Powders - Supplier Data By Quantachrome Instruments
Micropores require gas sorption technology: look for analyzers with advanced techniques like CO2 and argon adsorption combined with state-of-the-art DFT (Density Functional Theory) calculation models.
-
Summertime elemental mercury exchange of temperate grasslands
on an ecosystem-scale
Before each campaign the gas analyser was calibrated with argon as zero gas and pressurised air with 451 ppm CO2 as span gas.
-
Utilisation of post-consumer plastics in pre-reduction of higher manganese oxides in ferromanganese process
…Mn3O4) with high density polyethylene (HDPE) (at C/O molar ratios of 1?5, 2?0 and 3?0) were heated rapidly to 1150uC under pure argon and the off gas was measured continuously by an IR analyser for CO, CO2 and CH4.
-
Reduction of FeO in EAF steelmaking slag by blends of metallurgical coke and end-of-life polyethylene terephthalate
…of EAF slag (47?1%FeO) with coke, PET and blends of coke/PET (in four different proportions) were rapidly heated at 1550uC under high purity argon gas and the off gas … for CH4, CO and CO2 using an online infrared gas analyser (IR).
-
Thermal quenching effects on plasma synthesis of NO and plasma decomposition of CO2
NO and NOx are analyzed with a NOx analyzer (Shimazu, CLM-201) by the chemiluminescence method, while the gas chromatograph detects CO2 , CO, and 02, where the carrier gas was argon and two successive columns (silica gel and molecular sieve 13x) were…
-
An investigation of the effect of the electrolyte composition on the consumption of fired anodes during electrolytic aluminum production
…dc source, (3) ammeter, (4) control unit of gas flow controller, (5) El-Flow gas flow controller, (6) argon cylinder, (7) furnace, (8 … 12) thermometer, (13, 14) gas analyzer for CO Kedr-M … 15) gas analyzer for CO2 Kedr-M 30, (16…
-
Study of solid/gas phase photocatalytic reactions by electron ionization mass spectrometry
Abbreviations: λ, = wavelength; A, = ampere; Ar, = argon ; a.m.u., = atomic mass unit; a.u., = arbitrary unit; CO2 , = carbon dioxide; ecb - , = electron conduc- tion band; FT-IR … nitrogen dioxide; NOx, = nitrogen oxides; O2, = oxygen; RGA, = residual gas analyser ; TiO2, = titanium dioxide; UV…
-
Photoacoustic analysis of inorganic gases (review)
The radia- tion sources in laser PA gas analyzers are continuous and pulse lasers … and [IV spectral regions: a gas -discharge helium-neon laser … 5]; a gas- discharge CO2 laser with pulse or … 5 ~m [8] and argon lasing at 0.488…
-
Sterile neutrinos in cold climates
…nitrogen, alongside sub-percent levels of other gasses, including 5,700 ppm methane and 600 ppm argon . .... Locally at the CO2 well, an Ar- He-N2 mixture is extracted from the crude CO2 gas , with methane levels below the sensitivity on 1 the in situ gas analyzer [17].
Indicates content that may require registration and/or purchase.