Supplier: Polyguard Products, Inc.
Description: Zero-Perm® vapor barrier membrane from polyguard Products is an absolute “zero perm” barrier that provides maximum protection for all types of insulations used in below ambient, subfreezing and cryogenic applications on duct, pipe, or vessel systems. • Meets ASTM
- Applications: Ducting, Piping
- Form: Membrane/Sheeting
- Material: Aluminum, Other
- Thickness: 0.0787 inch
-
Supplier: KOSTER American Corporation
Description: ?Easy to apply ?VOC compliant. ?Little to no odor. ?Unaffected by a pH 14. (ASTM D-1308 test method) ?Up to 97% reduction in moisture vapor emissions (ASTM E-96-05) ?1056 psi (100%) cohesive failure of substrate. (ASTM D-7234) ?10 year, multi-million dollar
-
Supplier: KOSTER American Corporation
Description: method) ?Up to 97% reduction in moisture vapor emissions (ASTM E-96-05) ?1056 psi (100%) cohesive failure of substrate. (ASTM D-7234) ?10 year, multi-million dollar independently insured warranty.
-
-
Supplier: ASTM International
Description: 1.1 This document covers guidelines for specifying water vapor transmission (WVT) properties for above-grade water-resistive barriers and air barriers (WRB/AB), typically installed between building structural components and cladding that compose the exterior side of building
-
Supplier: ASTM International
Description: 1.1 This document provides guidelines for specifying water vapor transmission (WVT) properties for above-grade water-resistive barriers and air barriers (WRB/AB), typically installed between building structural components and cladding that compose the exterior side of building
-
Supplier: ASTM International
Description: 1.1 These test methods cover the determination of water vapor transmission rate (WVTR) of materials, such as, but not limited to, paper, plastic films, other sheet materials, coatings, foams, fiberboards, gypsum and plaster products, wood products, and plastics. Two basic methods, the
-
Supplier: ASTM International
Description: 1.1 These test methods cover the determination of water vapor transmission rate (WVTR) of materials, such as, but not limited to, paper, plastic films, other sheet materials, coatings, foams, fiberboards, gypsum and plaster products, wood products, and plastics. Two basic methods, the
-
Supplier: Mallard Creek Polymers, Inc.
Description: following performance advantages: moisture vapor barrier properties, enamel holdout at higher PVC's than conventional latexes, superior cold temperature coalescence, stability to alkaline substrates and ASTM E-96 perm ratings of ~0.5. Markets Utilized In Paper
- Material Type: Type: Styrenics
- Viscosity: 400 to 1000 cps
-
Supplier: CertainTeed Corporation
Description: C1104 < 5% • Water Vapor Permeance: – Permeance of Facing ASTM E96 Desiccant Method Unperforated facing: < 1.0 perm (57 ng/Pa•s•m2)
- Material Type: Glass / Fiberglass
- Overall Length: 1.33 to 2.67 yd
- Overall Thickness: 3.5 to 12 inch
- Overall Width / OD: 15 to 24 inch
-
Supplier: U.S. Plastic Corporation
Description: (both surfaces) (ASTM I-257 @ 12% RH): <10 12 Ohms. sq. in. *Static Decay (FTMS 101C, Method 4046.1 5000 to 0 Volts): <0.05 Seconds *Capacitive Probe Test (High Voltage Discharge) - (EIA-std 541/Appendix E-1 KV): <8 Volts *Charge Generation-nominal (Modified incline plane Avg. n
- Type: Bag / Sack
-
Supplier: Johns Manville Corp.
Description: 25/50 or less per ASTM E 84. The FSK-25 facing also serves as an excellent vapor retarder and may be left exposed where codes permit. The FSK-25 batts are a lightweight fire-resistant thermal and acoustical fiber glass insulation made of long, resilient glass fibers bonded with
- Applications: Fire Proofing / Thermal Protection, Architectural / Construction
- Overall Length: 1.33 to 2.67 yd
- Overall Width / OD: 15 to 24 inch
- Structural Features: Sound Proofing / Insulation, Thermal Insulation / Fireproofing, UL Approved / Listed
-
Description: A zero permeability, all-weather, multi-layered laminate coated with an aggressive cold weather acrylic adhesive, superior resistance to weathering, mold, UV and extreme environmental conditions. Designed for use as a vapor barrier for insulation cladding and jacketing applications.
- Adhesive: Acrylic
- Performance Features: Thermally Insulating / Insulative, UV / Weather Resistant
Find Suppliers by Category Top
Featured Products Top
-
barrier to protect against environmental factors that could lead to corrosion, extending the lifespan of the component. Unlike electropolishing — which also creates a passive layer but removes a precise amount of surface material through an (read more)
Browse Corrosion Protection Services Datasheets for Able Electropolishing Company, Inc. -
standard coated textiles can be manufactured in accordance with a variety of specifications including ASTM E84, ASTM E162, FAR 25.855, and MIL-PRF-20696F. Please visit “View By Specification” in our Technical Data Center for (read more)
Browse Textile Manufacturing Services Datasheets for Mid-Mountain Materials, Inc. -
fugitive emissions, protect personnel and warn of plant failures. These line-of-sight devices are typically located to provide a detection barrier around the perimeter of a plant, process or storage area; or positioned in close proximity to specific items of a plant that pose a real risk of gas escape: e.g. pump sets, pressure reducers, valves, and pipe flanges. (read more)
Browse Gas Instruments Datasheets for MSA Safety -
fugitive emissions, protect personnel and warn of plant failures. These devices are typically located to provide a detection barrier around the perimeter of a plant, process or storage area; or positioned in close proximity to specific items of plant, that pose a real risk of gas escape: e.g. pump (read more)
Browse Gas Instruments Datasheets for MSA Safety -
of the pump, the flow and head are easily controlled due to the steep nature of the performance curve. The ablity of the tubrine pump to handle entrained vapor makes it ideal for pumping volatile fluids near their boiling point to ensure there is no vapor lock. The hermetically sealed design (read more)
Browse Chemical Pumps Datasheets for Dickow Pump Company, Inc. -
channel is ideal for the tight space constraints of tanker trucks. Once the WPC pump is initially primed, the side channel pump will operate like a piston pulling vapor and liquid though the line ensuring no issues with vapor lock. Maximum flow of 55 m3/hr (242 gpm) and maximum differential (read more)
Browse Liquid Handling Pumps Datasheets for Dickow Pump Company, Inc. -
is ideal for the tight space constraints of tanker trucks. Once the WPC pump is initially primed, the side channel pump will operate like a piston pulling vapor and liquid though the line ensuring no issues with vapor lock. Maximum flow of 55 m3/hr (242 gpm) and maximum differential (read more)
Browse Liquid Handling Pumps Datasheets for Dickow Pump Company, Inc. -
additional cooling is required when the media has vapor pressure greater than atmospheric pressure at operating temperatures. Additionally, when handling fluids that crystallize in the atmosphere, an appropriate quench connection or barrier fluid must be provided. Various attempts have been (read more)
Browse Chemical Pumps Datasheets for Dickow Pump Company, Inc. -
safety, especially when handling toxic, explosive or other dangerous liquids which react on contact with the atmosphere. For all such services, the static shroud replaces double acting mechanical seals, along with external fluid reservoirs or barrier fluid circulating systems. Due to the fact that 90 (read more)
Browse Chemical Pumps Datasheets for Dickow Pump Company, Inc. -
, the static shroud replaces double acting mechanical seals, along with external fluid reservoirs or barrier fluid circulating systems. Due to the fact that 90% of pump failures and required service base on leaking mechanical seals, the sealless design will save maintenance and spare parts costs (read more)
Browse Chemical Pumps Datasheets for Dickow Pump Company, Inc.
More Information Top
-
Water Management of Noninsulating and Insulating Sheathings: Final Report
• Although all liquid applied barriers have vapor permeance data ( ASTM E96 ), a better understanding of how the installed thickness affects the expected vapor permeance of the coating is required.
-
Role of Vapor Barrier in Wood-Frame Stucco Wall in Various North American Climates: Observations from Hygrothermal Simulation
Water vapor per- meance for vapor barriers in these buildings, determined by ASTM Standard E96 /E96M-05, Test Methods for Water Vapor Transmission of Materials, desiccant method ͑dry cup͒, must not exceed 60 ng/͑Pa s m2 ͒.
-
Reducing Water Permeability while Maintaining Transparency of PET: A Plasma Immersion Ion Implantation Study
The gas barrier property against water vapor was measured using a weight gain method based on ASTM E96 -53T, as shown in the schematic diagram in Figure 2.
-
Presentation at ASTM C16 Symposium on Next-Generation Thermal Insulation Challenges and Opportunities
In the arena of vapor retarders (or vapor barriers ) and materials used to make vapor retarders, the question of how adequate and precise ASTM E96 is for testing extremely low WVTR has been raised in the producer, user, and testing commun- ities.
-
Characterization of polyhydroxyalkanoate blends incorporating unpurified biosustainably produced poly(3‐hydroxybutyrate‐ co ‐3‐hydroxyvalerate)
Water vapor permeability by weight loss or gain measurements ( ASTM E96 ) are common methods to determine the water barrier properties of materials, while D-Limonene is a commonly used standard compound to test mass transport of volatile compounds, such as aromas.
-
States > Minnesota > State > Register > 2009 > [2009 MN Register 302] 3/2/2009
In addition, an air barrier material and vapor retarder material with a minimum permeance of at least 1, in accordance with ASTM E96 procedure A, shall be installed on the warm-in-winter side of the foundation insulation meeting the following: a.
-
Generic Guide Specification for Geothermal Heat Pump Systems
Outer jacket/ vapor barrier to be as a minimum, fiberglass-reinforced, aluminized polyester film, with a maximum ASTM E96 permeance rating of 0.1 perm (grain/h/ft2 /in. Hg).
-
Countries > Canada > Province of Ontario > Regulations > Building Code Act > [CANADA Ont Reg 2012-332] Regulation 332/2012 - Building Code
(1) Vapour barriers shall have a permeance not greater than 60 ng/(Pa∙s∙m2), measured in accordance with ASTM E96 / E96M, "Water Vapor Transmission of Materials”, using the desiccant method (dry cup).