Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Description: standard applies to bolometric power meters as complete instruments and to their constituent parts: bolometric detectors, bolometer units, and bolometer elements. Bolometer power measurement instrumentation is generally used to measure, below 100 mW and above 10 MHz, the average
-
Supplier: Materion Corporation
Description: A Visi-Lid™ assembly is a filter/lid sub assembly, suitable for hermetically sealing detectors or bolometers. Each window assembly is spectrally and hermetically tested to assure compliance. This is a turnkey solution which avoids the having to perform the sub assembly and eliminates any
- Coating: None
- Materials: Germanium, Sapphire, Specialty / Other
- Window Shape: Circular, Square, Rectangular
-
Supplier: ValueTronics International, Inc.
Description: bolometer mounts (including HP Temperature Compensated Thermistor Mounts with cable P/N 138-652) Rack mountable Applications: RF Calibration Labs Used with System IIA to calibrate a wide variety of Tegam Gigatronics HP Other
-
-
Supplier: TEGAM, Inc.
Description: power measurements are important. These units are durable, highly accurate, and stable over time and temperature. They are ideal for use as standards for the transfer of calibration factors to Feedthrough power standards such as the 2510A or bolometer mount-coupler and bolometer
-
Supplier: TEGAM, Inc.
Description: the 1830A which is Direct Reading Thermistor Power Meter. The Model M1135A is a terminating thermistor Reference Standard. It is designed to be calibrated directly by a national standards agency such as NIST. The M1135A is used for the calibration of feedthrough devices such as bolometer
-
Supplier: OMEGA Engineering, Inc.
Description: OMEGA's THERMCOAT KIT is used for cementing fine-gage thermocouples in place on metal, plastic and ceramic surfaces and for assembling and installing thermopiles, temperature probes and thermocouple bolometers. THERMCOAT CO and THERMCOAT COL This is a fast-setting two
- Chemical / Polymer System Type: Ceramic / Inorganic Cement
- Cure Type / Technology: Air Setting / Film Drying, Thermosetting / Crosslinking, Single Component System
- Dielectric Constant (Relative Permittivity): 2.98 to 3.1
- Dielectric Strength: 2000 kV/in
-
Supplier: ValueTronics International, Inc.
Description: into lK); low and high current bolometer (4.5 and 8.7 ma ±3% into 200 ohms), positive bolometer protection. Input connector: BNC female. Input Frequency:1000 cps, adjustable 7%. Bandwidth: Variable, 15 to 130 cps. Typically, less than 0. 5 db change in gain from minimum to
-
Supplier: TEGAM, Inc.
Description: temperature. The Model 2505A is a feedthrough Thermistor standard used for the calibration of bolometer, thermo-couple, and diode terminating power sensors. The Model 2505A features a Type N female connector, and the 1510A features a compatible Type N male connector. These RF Power
-
Supplier: TEGAM, Inc.
Description: Metrology Institutes. The Model 1505A is a terminating thermistor Primary Transfer Standard. The 1505A is used for the calibration of feedthrough devices such as bolometermount-coupl er and bolometer mountsplitter RF Standards. It is also useful in other applications requiring direct
-
Supplier: OMEGA Engineering, Inc.
Description: . They are available in a variety of pixel resolutions and can meet the spatial resolution requirements of most applications. Eliminate the guesswork, see heat patterns with the thermal imagery and extract temperature values from live or recorded imagery. This instrument has uncooled micro
- Accuracy: 5 ±% Full Scale
- Ambient Temperature Range: 41 to 252 F
- Computer Host: PC
- Cooling: Uncooled
-
Supplier: ATV Technologie GmbH
Description: Common Applications SRO-714/716 IGBT/DBC Power Semiconductors Sensors/IR Bolometer Detector MEMS Devices DIE Attachment High Power LED Hybrid Assembly Flip Chip Package Sealing MMICs Transient liquid phase soldering/bonding Ag sintering Thermo compression bonding CPV, Laser bar
- Configuration: Bench / Cabinet
- Temperature Range: 450 F
-
Supplier: Larson Electronics LLC
Description: detecting range, has a field of view that measures 35° H x 27° V, and can rotate 360° x 135° tilt. It also comes in two speeds, fast and slow. The infrared camera has sensor type of 320 x 240 Uncooled micro bolometer. The LCD monitor is supported by a flexible neck and can be
Find Suppliers by Category Top
Featured Products Top
-
at first suppose, since it was a form of bolometer able to indicate the RMS value of the two voltage extremes on the line. Commonplace but pretty much gone in the RF industry by the 1990s, a bolometer fed with RF would be warmed by the RF resulting in a change in resistance in one arm of a (read more)
Browse Antennas Datasheets for A.H. Systems Inc.
Conduct Research Top
-
Using Agilent Temperature Compensated Thermistor Mounts with TEGAM Type IV Power Meters
Thermistor-based RF power sensors are known by many names including thermistor mounts, thermistor sensors and bolometers. Thermistor sensors such as the Agilent (HP) 478A and TEGAM F1109 are dual thermistor based. In dual thermistor sensors, a pair of thermistor beads is used to detect RF power
-
Applications of Infrared Imagery in the Monitoring and Diagnosis of Zoo Animals in Anchorage, Alaska
time zoo residents "Maggie" the elephant and "Borus" the Bactrian Camel. The digital thermograms gathered from a P-65 bolometer were edited, reviewed and reproduced. Through power point presentations and in-hand images, staff veterinarians and curators were able to recognize the areas of thermal
More Information Top
-
Physics and Applications of Terahertz Radiation
THz Bolometer Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
THE ROLE OF RADIATION ON THE POWER
…from the Alcator C tokamak plasma was measured with a 16 element, collimated, bolometer array and a…
-
Direct detectors for the Einstein inflation probe
The three detector types we will discuss are semiconductor-based bolometers , superconducting transition edge sensor (TES) bolometer…
-
Observing Photons in Space
29 Infrared imaging bolometers .
-
Terahertz Techniques
Semiconducting Bolometers .................................
-
Terahertz detectors and focal plane arrays
…detectors, focal plane arrays, Schottky barrier diodes, SIS detectors, SIN detectors, hot electron bolometers , transition edge sensors…
-
Uncooled Thermal Imaging Arrays, Systems, and Applications
1.2.2.1 Resistive bolometer / 4 .
-
Radio Frequency and Microwave Power Measurement
10 Bolometers 6.1 Barretters 6.2 Thermistors 6.3 Film bolometers 6.4 Determination of effective…
-
SCUBA-2: iterative map-making with the Sub-Millimetre User Reduction
Facility
The Submillimetre Common User Bolometer Array 2 (SCUBA-2) is an instrument operating on the 15-m…
-
Planck 2013 results X. Energetic particle effects: characterization,
removal, and simulation
These interactions fall into two categories, heating the 0.1 K bolometer plate and glitches in each…
Indicates content that may require registration and/or purchase.