Supplier: Process Sensing Technologies USA
Description: The LD8000-TCD analyzer offers direct and continuous measurements of a gas component in a binary gas mixture. It is a compact, rack-mountable unit for industrial & laboratory use. It uses a Thermal Conductivity Detector (TCD) enabling measurements in the ppm to % measurements
- Operating Temperature: 50 to 113 F
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
Supplier: Emerson Automation Solutions – Rosemount
Description: has dual-detector capabilities in one application. Benefits include shorter analysis time and improved sensitivity. This instrument also supports TCD (thermal conductivity detectors), FID (flame ionization detectors) and FPD (flame photometric detectors).
- Oven Temperature Range: 302 F
- Inlet Pressure Range: 15 to 100 psi
- Number of Injection Ports: 6
- Operating Temperature: 0 to 130 F
-
Supplier: Siemens Analytical Products
Description: permit and optimum solution for almost every application Wide range of detectors including FID, TCD, FPD, PDD (HID, PID, or ECD mode) Single or multi-detector configurations make this the most versatile Process Gas Chromatograph available Numerous types of valves for the optimum
- Oven Temperature Range: 140 to 536 F
- Inlet Pressure Range: 5.07628937750189 to 300.226257469398 psi
- Operating Temperature: 0.4 to 122 F
- Output Options: Analog Current, Analog Voltage
-
-
Supplier: Micromeritics
Description: volume assures high resolution, fast detector response, and reduces error when calculating gas volumes. Highly sensitive linear thermal conductivity detector (TCD) assures the calibration volume remains constant over the full range of peak amplitudes so the area under the
- Properties Analyzed: Adsorption / Desorption (Chemisorption/ Physisorption), Surface Area - Total
- Display & Special Features: Analog Meter
- Test Media: Chemicals, Metals
- Mounting / Loading Options: Laboratory / Batch
-
Supplier: Micromeritics
Description: released from the sample surface is monitored by a Thermal Conductivity Detector (TCD). Data obtained by the instruments can be used to calculate key parameters for catalyst characterization: metal dispersion, active surface area, BET surface area, average crystallite size, surface
- Specific Surface Area Range: 0.02
- Total Surface Area Range: 0.02 to 199.9 m²
- Properties Analyzed: Adsorption / Desorption (Chemisorption/ Physisorption), Contamination (Shives, Dirt, Bacteria), Surface Area - Specific, Surface Area - Total
- Test Media: Chemicals, Metals
Find Suppliers by Category Top
More Information Top
-
The Role of the Hydrogen Source on the Selective Production of γ‐Valerolactone and 2‐Methyltetrahydrofuran from Levulinic Acid
The samples were then heated to 450 8C by a 10 K minÀ1 ramp, and the release of NH3 was monitored using a calibrated TCD detector .
-
Control of the Basicity in Ni–MgO Systems: Influence in the Hydrogenation of Styrene Oxide
The basic properties of the solids were characterized by TPD of CO2 using a TPD/R/O 1100 (Thermo Finnigan) equipped with a programmable temperature furnace and a calibrated TCD detector .
-
Redox Kinetics of Ceria‐Based Mixed Oxides in Selective Hydrogen Combustion
[a] Data obtained by calibrating the TCD detector with a CuO standard.
-
Catalysts based on gold nanosized species incorporated into zeolites
The amount of H2 consumed for the reduction of oxidic species was measured by TCD and estimated from the integrated areas of the peak profiles obtained using absolute calibration of TCD detector .
-
Nanostructured Manganese Oxide Supported on Carbon Nanotubes for Electrocatalytic Water Splitting
The TCD detector was calibrated by reducing a known amount of CuO.
-
USING ANAEROBIC CO-DIGESTION WITH ADDITION OF
MUNICIPAL ORGANIC WASTES AND PRE-TREATMENT TO
ENHANCE BIOGAS PRODUCTION FROM WASTEWATER
TREATMENT PLANT SLUDGE
The contents of the gas samples (CH4 and CO2) were analyzed by gas chromatography (Agilent 3000 Micro GC with Plot U backflush module, TCD detector ) calibrated on a volume basis (V/V).
-
Kinetic and activity study of CO oxidation over CuO–MnOx –CeO2 catalysts
The amount of H2 consumption was determined by a gas chromatograph with a TCD detector , calibrated by the reduction of a known amount of CuO powder.
-
Supported Cu Catalysts with Yttria-Doped Ceria for Steam Reforming of Methanol
The TCD detector was calibrated using a standard CuO sample.
-
Fe-ZSM-5 Catalyst Prepared by Ion Exchange from Fe(acac)3 : Application into NH3 -SCR of NO
The calibration of the TCD detector was achieved by reducing a known amount of Cu(II) oxide.
-
Skeletal isomerization of unsaturated fatty acids: the role of mesopores in HBeta zeolites
Desorbed species were moni- tored with a calibrated thermoconductivity detector ( TCD ) as well as a mass spectrometer.
Indicates content that may require registration and/or purchase.