Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: ABB Measurement & Analytics
Description: Analyzers have an internal computer (Linux OS) that can store data practically indefinitely on a hard disk drive and send real time data to a data logger via the digital (RS232), analog or Ethernet outputs. In addition, LGR analyzers may be controlled remotely via the Internet. This
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
Supplier: ABB Measurement & Analytics
Description: N2O/CO Analyzer in a portable package (http://bit.ly/1SEwwRR). Similarly, for simultaneous, reliable and accurate measurements of ammonia, methane, carbon dioxide and water vapor, LGR now offers our Soil Gas Analyzer (http://bit.ly/1Yl30Ed). LGR’s patented technology, a
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
Supplier: Owlstone Inc.
Description: Lonestar is a portable gas analyzer that can detect a broad range of analytes at part per billion concentrations, with high selectivity in just a few seconds.
- Operating Temperature: 41 to 104 F
- Operating Humidity: 5 to 90 %
- Response Time: 1.000000000000002 seconds
- Measurement Type: %Volume, Signature or Spectra, Trace
-
-
Supplier: ABB Measurement & Analytics
Description: LGR's Greenhouse Gas Analyzer (model GGA-24EP) is the world's most advanced instrument for simultaneous measurements of methane (CH4), carbon dioxide (CO2) and water vapor (H2O). Quite simply, no other analyzer provides higher performance. (For details, please see:
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
Supplier: ABB Measurement & Analytics
Description: analyzers to make true measurements at data rates of 20 Hz makes them excellent choices for eddy covariance flux measurements and for mobile leak (e.g., natural gas, coal seam gas, coal bed methane) detection. The analyzer uses ABB’s patented Off-axis ICOS technology, the
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Instrument Type: Analyzer
- Gas Types: Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
- Number of Gases Monitored: Multi Gas
-
Supplier: Environment One Corporation
Description: Environment One's standard Generator Gas Analyzer (GGA) can also be supplied in a portable configuration. The PGA incorporates the same hydrogen gas sensor/analyzer and system electronics found in our other hydrogen gas purity systems. The PGA is specifically
- Number of Channels: 1
- Operating Temperature: 32 to 125 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Leakage
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Other
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Process Sensing Technologies USA
Description: The LD8000 MultiGas is an online gas analyzer to monitor trace N2, O2, H2O, CnHm in Helium. The compact 4U unit has been designed to meet the requirements of the Helium cryogenic installations for online measurement. Features: Compact rackmount enclosure (3U or 4U) to cover up to four
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
Supplier: Siemens Process Instrumentation
Description: measurement of complex gas mixtures is also possible in many cases. This ensures measurements of low concentrations as well as low detection limits. Appropriate materials in the gas channel allow the analytical devices to be used even for measurements of gas mixtures with
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrocarbons, Methane (CH4) / Natural Gas, Nitric Oxide (NO), Sulfur Dioxide (SO2), Toxic Gas
- Application: Continuous Emissions Monitoring, Process Gas
-
Supplier: Fuji Electric Corp. of America
Description: Insertion type offers high-speed measurement. Long-term stability and low maintenance. ZSS Laser Gas Analysers for : waste incinerators, district heating and industrial boilers, chemical plant. NH3 – HCI – CO – O2 – CO2 – CH4
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrogen Chloride (HCl), Methane (CH4) / Natural Gas, Oxygen (O2)
- Application: Confined Space Monitoring
- Mounting Type: Fixed
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Laser raman gas analyze?r LRGA-6000 is an advanced equipment that can online measure all the gas composition of most fuel gases, including biogas, syngas, natural gas, producer gas and so on. And with the unique advantages of no consumables, higher accuracy, long
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrocarbons, Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Oxygen (O2), Water Vapor
-
Supplier: Taylor Dynamometer, Inc.
Description: Taylor Dynamometer is proud to offer a cost-effective emissions analyzer for use with Taylor’s DynPro data acquisition and control system. The system offers superior functionality and an elegantly simple design for a seamless integration with the DynPro system. The Emissions Gas
-
Supplier: Siemens Process Instrumentation
Description: an innovative multi-component gas analyzer which can be equipped with the following sensors: IR detector for IR-active gases, UV photometer for UV-active gases, H2S sensor (electrochemical), O2 sensor (electrochemical or paramagnetic), and used accordingly in numerous applications and
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Oxygen (O2), Sulfur Dioxide (SO2), Sulfur Hexafluoride (SF6), Toxic Gas
-
Supplier: Siemens Analytical Products
Description: The "Combi-Analyzer" ULTRAMAT/OXYMAT 6 combines the features of the ULTRAMAT 6 and OXYMAT 6 in one analyzer in a 19" rack design. Most frequently used for demanding applications, the ULTRAMAT 6 must meet high standards with regard to reliability and measuring quality. This is
- Operating Temperature: 41 to 113 F
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Sulfur Dioxide (SO2)
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Portable natural gas analyzer Gasboard-3110P is a portable type analyzer and the best alternative of GC and MS that can be used for online measurement for natural gas composition and heating value second by second. It is widely used in various applications such as natural
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Siemens Process Instrumentation
Description: and optimization of flue gas cleaning systems by measuring the waste gas concentrations before and after gas cleaning steps. Internal combustion engines: Measuring the ammonia slip behind DeNOx catalysts in the waste gas system of engine test beds Explosion safety:
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Oxygen (O2), Toxic Gas, Water Vapor
- Instrument Type: Analyzer
- Display: Digital
- Number of Gases Monitored: Multi Gas
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O
- Response Time: 15 seconds
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online syngas analyzer Gasboard-3100 is a stationary analyzer with standard 19'' 3U rack enclosure, easy to be integrated inside industrial system. It is able to online continuously measure volume concentration of CO, CO2, CH4, H2 , O2 , CnHm, C2H2 , C2H4 simultaneously, and
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
-
Supplier: Fuji Electric Corp. of America
Description: Multigas analyser compact and light high performance multigas analyser. The ZSVS up to 4 gas components concentration measurement. Suited for gas monitoring in heat treatment furnaces, plant cultivation, and research-purpose chemical analysis. CO2 – CO – CH4 – O2
- Response Time: 50 seconds
- Operating Temperature: 32 to 104 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online biogas analyzer Gasboard-3200 is a rack type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S with high accuracy, stable performance, can be easily integrated with biogas analysis system, widely used in anaerobic digestion biogas, waste water
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Emerson Automation Solutions – Rosemount
Description: measurement capability Robust all solid state See the Features & Benefits tab below for more details. Cascade’s CT4000 system monitors in real time NO, NO2, SO2, CH4, H2O, CO and CO2 levels in ambient environments of up to 70°C (158°F) and gas temperatures of 190°C (374°F).
- Operating Temperature: -4 to 158 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 5000 Series Portable Flue Gas analyzer has been designed for accuracy, reliability, ease of use and ease of service, providing a detailed analysis of flue gas composition. The 5000 uses customer replaceable sensors which respond quickly to the O2, CO2, SO2, CO, and NOx
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Nova Analytical Systems Inc.
Description: integral to the main analyzer cabinet, and the gas analysis sensors which are mounted in a separate but integral rack mount drawer, which eases service and maintenance.Other gases can be included as part of this platform, including CH4, SO2, NO, and NO2 in % or PPM ranges.
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
Supplier: Panametrics
Description: The new XMTCpro is a compact, rugged, online thermal conductivity transmitter that measures the concentration of binary gas mixtures including hydrogen, carbon dioxide, methane, helium and many others. Featuring real-time error detection and enhanced signal measurement for fastest response,
- Response Time: 20 seconds
- Operating Temperature: -4 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
Supplier: BlueSens Gas Sensor GmbH
Description: minimum gas volumes produced during the running experiment. As the experiment is started, the CH4 concentrations and the gas volumes are recorded automatically. With the integrated temperature measurement the software BACVis immediately converts the measured gas into the
- Gas Types: Methane (CH4) / Natural Gas
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Continuous gas analysis for process and emission monitoring applications, combining TDL and QCL technologies to measure up to twelve components simultaneously down to low ppm. Improve Measurement Control with Fast, Reliable, Real-time Data Quantum Cascade Laser (QCL) multi-component
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Measurement Type: %Volume, Trace
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxides (NxOx), Oxygen (O2), Sulfur Dioxide (SO2)
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 320 Series of Portable Flue Gas Oxygen Analyzers utilize a reliable, stable oxygen sensor which responds quickly to the oxygen present in the flue gas sample. Its life expectancy is between 3 and 4 years. The sensor is very easy for the customer to replace.A
- Response Time: 8 seconds
- Operating Temperature: 32 to 105 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Siemens Analytical Products
Description: and the gas temperature in furnaces and boilers. Surveillance and optimisation of flue gas cleaning systems by measuring the waste gas concentrations before and after gas cleaning steps. Internal combustion engines: Measuring the ammonia slip behind DeNOx catalysts in the
- Operating Temperature: 41 to 113 F
- Measurement Type: %Volume, Trace
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Oxygen (O2), Toxic Gas
- Electrical Outputs: Analog Current
-
Supplier: BlueSens Gas Sensor GmbH
Description: Therefore the BlueInOne Ferm gas analyzer is neither affected by the gas flow nor by humidity in the process. This state-of-the-art combined gas analyzer stands for highest precision and reliability. Advantages: parallel measurement of O2 and CO2 Modbus OPC server
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 310 Series Portable Flue Gas CO Analyzer utilizes a reliable, customer-replaceable electrochemical sensor which responds quickly to the CO present in the flue gas sample. Its life expectancy is between 2 and 3 years. The flue gas sample drawn into the
- Response Time: 20 seconds
- Operating Temperature: 32 to 105 F
- Measurement Type: %Volume, Trace
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
-
Supplier: Process Sensing Technologies USA
Description: The MoGas Medical gas analyzer range is a wall or surface mounting instrument designed for use on Medical Oxygen Generation systems for checking the purity of the Oxygen produced. The MO2GA93 range is specifically designed for Medical Oxygen Generation systems producing Oxygen at 93%
- Operating Humidity: 15 to 95 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
- Gas Types: Oxygen (O2)
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Derived from the X-STREAM process gas analyzer, the X-STREAM Enhanced analyzer leads the industry in analytical capabilities and takes process gas analysis to the next level. Offering enhanced performance, extended communication capabilities, and maximum ease of use, the
- Number of Channels: 5
- Response Time: 30 seconds
- Operating Temperature: -40 to 140 F
- Operating Humidity: 0 to 100 %
-
Supplier: Process Sensing Technologies USA
Description: H2, N2, He, CO2, or Ne Welding gas control Steel Mills: CO2 in off-gas from gas generators Petroleum Refineries: H2 purity in C1 - C6 hydrocarbons Speciality gas laboratories Heat Treating: H2 in N2 and other annealing gases Process control Power Generation Plants: H2
- Operating Temperature: 50 to 113 F
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
Supplier: Pem-Tech, Inc.
Description: Model PT605 on stream monitor / analyzer has been designed for the detection of Hydrogen Sulfide in process streams and in Natural Gas Pipeline. The system is cost effective yet highly accurate and reliable. An industry standard 4-20mA output and three programmable alarm relay contacts
- Number of Channels: 1
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Data Logger, Hazardous Environments, Self Calibration
Find Suppliers by Category Top
Featured Products Top
-
To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly (read more)
Browse Oil Sensors and Analyzers Datasheets for BARTEC -
To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties (read more)
Browse Oil Sensors and Analyzers Datasheets for BARTEC -
replacement of the mechanical switch without rewiring or reprogram the PLC. The multi-function 1XTXSW loop powered hybrid transmitter with 2 solid state relays enabled the user to extract the 4-20 mA signal to monitor the temperature trending in the host system and simultaneously use the (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
replacement of the mechanical switch without rewiring or reprogram the PLC. The multi-function 1XTXSW loop powered hybrid transmitter with 2 solid state relays enabled the user to extract the 4-20 mA signal to monitor the temperature trending in the host system and simultaneously use the relay (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
A Quick Guide to Calibrating CEM Gas Analyzers Calibrating Continuous Emissions Monitoring (read more)
Browse Manifolds and Manifold Systems Datasheets for Environics, Inc. -
combustion efficiency of the stack. The CalorVal BTU analyzer was the analyzer of choice for a number of reasons. It has the ability to accurately and continuously measure the direct BTU content of the varying waste gas stream. It is real time measurement and will quickly respond (< 4 sec) to the (read more)
Browse Combustion Analyzers Datasheets for Control Instruments Corp. -
PrevEx Flammability Analyzers, fomerly the 670 Series, work where other analyzers fail. PrevEx Flammability Analyzers solve all of the sampling, measuring, and reporting problems found in industrial process applications for LFL(lower flammable limit/ LEL monitoring. Prev (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp. -
The new moisture analyzer packaged solution simplifies the selection and installation of your moisture analyzer. Only a few simple steps; install the moisture transmitter, and connect your loop power and sample gas or liquid to the inlet fitting and you are ready to measure. Other (read more)
Browse Moisture Meters Datasheets for Panametrics -
ensures users that the Vanguard WirelessHART gas detector’s design and operability, which were tested by Technical Inspection Association (TUV), will perform as indicated and detect any possible leak of combustible gases, such as methane (CH4) or propane (C3H8). “This (read more)
Browse Gas Instruments Datasheets for United Electric Controls Company -
Flare XGF1100 Flare Transmitter —designed to deliver reliable flare gas measurements in demanding operating environments. Why the XGF1100 High accuracy where it matters most First ultrasonic flare transmitter with up to 4 paths Real time emissions (read more)
Browse Flow Controllers Datasheets for Panametrics
Conduct Research Top
-
Process Gas Monitoring in Petroleum Refineries
Emerson provides Rosemount Analytical gas analyzer technology for on-line analysis of ammonia plant streams. Strategically placed gas analyzers improve the process efficiency and the purity of the end product. Ammonia is used in the production of a variety of products including fertilizer, nitric
More Information Top
-
Measurement of methane flux over an evergreen coniferous forest canopy using a relaxed eddy accumulation system with tuneable diode laser spectroscopy detect...
…diaphragm pumps (CV-201, Enomoto Co., Tokyo, Japan), four reservoirs (CCK-20; GL 161 Science, Tokyo, Japan) to accumulate sampled gas, a CO2/H2O gas analyzer (LI-840; Li-Cor Inc., Lincoln, 162 NE, USA), a CH4 gas analyzer (Baer et al. 2002…
-
Environmental and vegetation controls on the spatial variability of CH4 emission from wet-sedge and tussock tundra ecosystems in the Arctic
Methods CH4 fluxes were measured in four sites across a variety of wet-sedge and tussock tundra ecosystems in Alaska using chambers and a Los Gatos CO2 and CH4 gas analyser .
-
Climatic variability, hydrologic anomaly, and methane emission can turn productive freshwater marshes into net carbon sources
The system comprises of a sonic anemometer (CSAT3, CSI), an open-path CO2/H2O infrared gas analyzer (LI7500, LI-COR, Inc. (LI-COR), Lincoln, NE, USA), and an open-path CH4 gas analyzer (LI7700, LI-COR).
-
Carbothermal Solid State Reduction of Stable Metal Oxides
The off gas was analysed using infra-red CO/CO2/ CH4 gas analyser .
-
Comparison of greenhouse gas fluxes and nitrogen budgets from an ombotrophic bog in Scotland and a minerotrophic sedge fen in Finland
The lengths of the heated inlet lines for the CO2 and CH4 gas analyzers were 8.1 and 16.6 m, respectively (Aurela et al., 2009).
-
Catalyzed Ceramic Burner Material
CH4 Gas Analyzer Horiba Instruments Incorporated VIA-510 Configured for CH4 measurement, 0- 50/100/500/1000ppm ranges.
-
Automated modular complex MPPA-SSi12 – a breakthrough technology for “liquid” cementation
The composition of the furnace atmosphere was determined using three-component (CO, CO2, CH4 ) gas analyzer PGA3500 made by SSi (U.S.) and hydrogen gas analyzer IVA-1V made by the company Khimavtomatika (Moscow).
-
Measurement Techniques and Instrumentation
CO, CO2, SF6, N2O, C2H6, CH4 Residual gas analyzer ͑mass spectrometer͒ .
-
Atmospheric observations at the Amundsen-Nobile Climate Change Tower in Ny-Ålesund, Svalbard
Furthermore, the gas inlet for a Picarro Cavity Ring-Down Spectroscopy (CRDS) gas analyzer for CH4 and CO2 concentration measure- ments was also positioned in the same place, fixing acquisition system was at the ground close to the CCT basement.
-
Examining the Cu–Mn–O Spinel System as an Oxygen Carrier in Chemical Looping Combustion
Equations (13) and (14) were employed to calculate w as a function of time during the reduction period from the measured concentrations of vari- ous gaseous species in the gas analyzer for CH4 and syngas cycles, respectively: .
Indicates content that may require registration and/or purchase.