Supplier: ASTM International
Description: cooling experiments, within this temperature range, may be used to provide temperature calibration on cooling at other temperature ranges. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 Test
-
Supplier: CSA Group
Description: ISO 11357-1:2016 specifies several differential scanning calorimetry (DSC) methods for the thermal analysis of polymers and polymer blends, such as - thermoplastics (polymers, moulding compounds and other moulding materials, with or without fillers, fibres or reinforcements), - thermosets
-
Description: ISO 11357 specifies several differential scanning calorimetry (DSC) methods for the thermal analysis of polymers and polymer blends, such as thermoplastics (polymers, moulding compounds and other moulding materials, with or without fillers, fibres or reinforcements); thermosets (uncured or
-
-
Supplier: ASTM International
Description: dynamic mechanical analyzers (DMAs). 1.3 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It
-
Supplier: ASTM International
Description: units of measurement are included in this standard. 1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and
-
Supplier: NETZSCH-Gerätebau GmbH
Description: DSC 204 F1 Phoenix®, DSC 200 F3 Maia®, DSC 404 F1 Pegasus®, STA 449 F1 Jupiter® with unique FRC correction. BeFlat® Correction of temperature and heating rates dependent base line deviations with the DSC 204 F1 Phoenix®, DSC 200 F3 Maia®, DSC 204 HP
-
Supplier: Piezo-Metrics
Description: Strain gauge to RS485 or CAN digital load cell converter Low profile, small 20 mm diameter for mounting inside sensor Auto calibration or direct entry of mV/V with linearisation Ultra high performance, resolution of 1 part in 200,000 (18bit) Option of an in-line enclosure ATEX component
- Operating Temperature: -40 to 185 F
-
Supplier: Microstar Laboratories, Inc.
Description: to 70 mA quarter-, half-, and full-bridge resistor networks 120 and 350 ohm resistors as standard options any value resistor networks, sensor by sensor 10 full-scale options: +/-10 mV, +/-20 mV, +/-50 mV, +/-100 mV, +/-200 mV, +/-500 mV, and +/-1, +/-2, +/-5, and +/-10 Volts programmable gain
Find Suppliers by Category Top
More Information Top
-
Thermodynamic investigations of nitroxoline sublimation by simultaneous DSC‐FTIR method and isothermal TG analysis
… mined data of indium in this DSC system were 156.58C and 3.293 KJ/mol, which were very close to that of the literature transition temperature at 156.68C and enthalpy value of 3.296 KJ/mol for indium DSC calibration standard , respectively.
-
A new approach to DSC calibration in wax/polymer blending
Other DSC calibration standards .
-
Is Universal, Simple Melting Point Prediction Possible?
point.[70–74] However, in a strict sense, the above recommenda- tion is only applicable to materials of high purity (e.g. 99.999% indium, a DSC calibration standard ).
-
Mathematical modeling for the pultrusion of polymethyl methacrylate based composites
The temperature and power calibration of the DSC were optimized within the temperature range of 30–300 C using indium as the DSC calibration standard .
-
Evaluation the effect of cyclodextrin complexation on aqueous solubility of fluorometholone to achieve ophthalmic solution
Empty 40 lL crucibles were used as reference and the apparatus was calibrated with DSC calibration standard .
-
Chemorheology of unfilled and filled epoxy resins
The temperature and power calibra- tion of the DSC were optimized for the temperature range of 20 to 300°C by using indium as the DSC calibration standard .
-
The effect of free radical initiators and fillers on the cure of unsaturated polyester resins
The temperature and power calibration of the DSC were optimized for the temperature range of 20 to 200°C by using Indium as the DSC calibration standard .
-
A nonisothermal differential scanning calorimetry study of the curing kinetics of an unsaturated polyester system
The tem- perature and power calibration of the DSC were op- timized for the temperature range of 20-300°C by using indium as the DSC calibration standard .
-
Kinetic studies of a composite thermoset cure reaction—application in pultrusion simulations
The temperature and power calibration of the DSC was optimized for the temperature range of 20-300°C by using indium as the DSC calibration standard .
-
Three‐dimensional simulations of the curing step in the resin transfer molding process
The temperature and power calibration of the DSC were optimized for the temperature range 30-300°C by using Indium as DSC calibration standard .