Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Description: other products and equipment. ISO 11137-1:2006 covers radiation processes employing irradiators using the radionuclide 60Co or 137Cs, a beam from an electron generator or a beam from an X-ray generator. ISO 11137-1:2006 does not: specify requirements
-
Supplier: ASTM International
Description: 1.1 This practice covers dosimetric procedures to be followed in facility characterization, process qualification, and routine processing using electron beam radiation to ensure that the entire product has been treated with an acceptable range of absorbed doses. Other procedures
-
Supplier: CSA Group
Description: other products and equipment. ISO 11137-1:2006 covers radiation processes employing irradiators using the radionuclide 60Co or 137Cs, a beam from an electron generator or a beam from an X-ray generator. ISO 11137-1:2006 does not: specify requirements
-
-
Supplier: ASTM International
Description: 1.1 This practice covers dosimetric procedures to be followed in facility characterization, process qualification, and routine processing using electron beam radiation to ensure that the entire product has been treated with an acceptable range of absorbed doses. Other procedures
-
Supplier: CSA Group
Description: beam from an electron generator or c) a beam from an X-ray generator. 1.2 This part of ISO 11137 does not specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie,
-
Supplier: SAE International
Description: used to cure pre-pregs made with a specialty matrix material using the same molds, but doing so without adding any heat for curing. High energy X-ray equipment, generated from a 7 MeV, 700 kW electron beam, is in commercial use for medical device sterilization. This same
-
Supplier: Arnold Magnetic Technologies
Description: quality. These applications include fabrication of electron beam equipment for food sterilization, vulcanizing, and a variety of industrial uses; design and building of flight and aerospace vehicles; energy-related applications such as solar panels; speaker components;
- Applications: Aerospace / Aircraft (AQ), Alternative / Renewable Energy, Biocompatible / Biomaterial
- Features: Corrosion Resistant
- Metal / Alloy Types: Refractory / Reactive (UNS R), Titanium / Titanium Alloy
- Overall Thickness: 8.00E-5 to 0.0250 inch
-
Supplier: Sugatsune America, Inc.
Description: attributes, which meet FDA standards. It can hold up against ethylene oxide, gamma radiation, steam autoclaving, electron beams, and dry heat without altering its properties. Resistant to Organic Chemicals Food processing uses organic acids such as lactate and lactic acid, citric acid
- Inside Diameter: 0.4375 inch
- Overall Thickness: 0.3750 inch
- Shape: Round
Find Suppliers by Category Top
Featured Products Top
-
quality. These applications include fabrication of electron beam equipment for food sterilization, vulcanizing, and a variety of industrial uses; design and building of flight and aerospace vehicles; energy-related applications such as solar panels; speaker components; and medical device enclosures (read more)
Browse Industrial Magnets Datasheets for Arnold Magnetic Technologies -
-uses. See available options Customers rely on us as a thin-rolled titanium foil supplier. Ti is used in applications that demand high performance and consistent quality. These applications include fabrication of electron beam equipment for food sterilization, vulcanizing, and a (read more)
Browse Metal Strip Datasheets for Arnold Magnetic Technologies -
renowned Professor of Chemical Engineering and has served as a consultant for various U.S. Government agencies. He holds numerous patents and is credited with being the first person to develop electron beam radiation curing. How is Master Bond different from its competitors? (read more)
Browse Industrial Adhesives Datasheets for Master Bond, Inc.
Conduct Research Top
-
Low-Energy Electrons Have Pharma Beaming
By Paul Thomas, Senior Editor Do you consider this to be a "breakthrough " technology, or is there another term you would use? The commercial availability of small, low-energy electron beam systems for sterilization is relatively recent ( <10 years). I consider it an "enabling technology
-
Low-Energy Electrons Have Pharma Beaming
of pharmaceutical aseptic processing has been the popularization of low-energy electron beam technology for sterilization --the topic generated quite a bit of buzz at 2008 's ISPE annual meeting in Boca Raton, as well as at Pack Expo in Chicago. While high-energy electron beams have been used in a variety
-
Amgen: Do Electron Beams Impact Large Molecules?
This quick, one-time registration gives you access to members-only site benefits. As low-energy electron beams have gained acceptance in pharmaceutical aseptic processing and packaging, companies have done due diligence to research whether or not the technology could have any impact to the drug
More Information Top
-
Electron beam sterilization system.
Equipment for sterilization of food containers by electron beam irradiation includes: a conveyor; an electron beam irradiation unit; a unit for storage of process contol data (values for beam current, acceleration voltage, scan frequency and scan width); a unit for checking that …
-
System and method for inspecting electron beam sterilization of food container.
Equipment for sterilization of food containers by electron beam irradiation includes: a conveyor; an electron beam irradiation unit; a unit for measurement of a physical parameter of the container material which is altered by irradiation; and a unit for assement whether values …
-
Effect of microwave radiation on Bacillus subtilis spores
increasingly stringent anti-air-pollution standards; electron beams require extremely expensive machinery, and steril- ization equipment using c-ray sources is strictly regulated for safety and control restraints.
-
Electron beam sterilization system.
Equipment for sterilization of food in containers through electron beam irradiation is described.
-
Electron beam sterilization system.
An electron beam sterilization system is described which includes electron bean irradiating equipment for irradiating a food conatiner conveyed on a conveyor, equipment for controlling the electron beam and the conveyor and equipment for ensuring that sterilization of the food has taken …
-
Sterilization of Mail by Means of an Electron Beam Accelerator
Industrial electron beam accelerators are widely used for sterilization of medical equipment , drugs, food, and packing materials.
-
Uses of electron‐beam irradiation to prepare pH‐ and temperature‐sensitive hydrogels from reactive poly(vinyl alcohol) grafts
High-energy electron beam has found numerous applications ranged from sterilization of medical equipment to curing of coating or composites.21 The use of electron beam to initiate polymerization reac- tions is one area to which much interest has been focused.
-
Synthesis of charged linear and crosslinked maleic diester polymers with electron‐beam irradiation
High-energy electron beams have found numerous applications ranged from sterilization of medical equipment to curing of coating or composites.15 The .
Indicates content that may require registration and/or purchase.