Supplier: Sentinel
Description: The Model 959M portable gamma radiographic exposure device is specifically designed as a Small Controlled Area Radiography (SCAR) system. The SCAR projector is used primarily for the radiography of standard or difficult joint geometries without disruption and the need for
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Flaw Detection
- Technology: Radiographic / X-ray
-
Supplier: Sentinel
Description: The Model 979 crawler head is exclusively designed for use with gamma radiography crawlers containing a Selenium-75 source. It is compatible with (gamma crawler specific) mechanical and electromechanical actuators. Self propelled pipeline crawlers are inserted into pipelines
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Flaw Detection
- Technology: Radiographic / X-ray
-
Supplier: Sentinel
Description: The SENTINELTM Model 865 source projector is a Type B(U) package and consists of a stainless steel housing sealed against tampering or the entrance of dirt or water. It is ideal for underwater radiography. The projector has been proven in sea water at depths up to 2000 ft (609 m
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Flaw Detection
- Technology: Radiographic / X-ray
-
-
Description: relevant national transport regulations). The operational use of apparatus for industrial gamma radiography is not covered by ISO 3999:2004. Users of this equipment shall comply with national regulations and codes of practice.
-
Supplier: Sentinel
Description: Model 880 series source projectors are used for industrial applications of gamma radiography to inspect materials and structures in the density range of approximately 2.71 g/cm3 through 8.53 g/cm3. SENTINELTM Model 880 Delta, 880 Elite and 880 Omega source
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Flaw Detection
- Technology: Radiographic / X-ray
-
Supplier: Accuris
Description: For Gamma Radiography - Specifications for the Design, Testing, and Performance Requirements for Industrial Gamma Radiography System Equipment Using Radiation Emitted by a Sealed Radioactive Source
-
Supplier: CSA Group
Description: relevant national transport regulations). The operational use of apparatus for industrial gamma radiography is not covered by ISO 3999:2004. Users of this equipment shall comply with national regulations and codes of practice.
-
Description: radiation exposure, controlling radiation exposure, detection and measurement of radiation, gamma radiography equipment, and operation, emergency, and transportation procedures. Pertinent USNRC information (forms, publications, regional offices, agreement states, etc.) is also
-
Supplier: ASTM International
Description: 1.1 This practice establishes the minimum requirements for computed radiographic (CR) examination for metallic and nonmetallic materials using X-ray or gamma radiation. 1.2 Applicability-The requirements in this practice are intended to control the quality of computed
-
Supplier: Carestream NDT
Description: industry. The new HPX-1 Plus CR system builds on this solid foundation, and raises the bar even higher, to make NDT radiography easier, more productive, more accurate, and more affordable. The HPX-1 Plus offers many improvements. Improved optics for better imaging, up to 30
- Form Factor: Portable / Hand Held / Mobile
- Instrument Type: Other
- Technology: Radiographic / X-ray
-
Supplier: Carestream NDT
Description: industry. The new HPX-1 Plus CR system builds on this solid foundation, and raises the bar even higher, to make NDT radiography easier, more productive, more accurate, and more affordable. The HPX-1 Plus offers many improvements. Improved optics for better imaging, up to 30
- Form Factor: Bench / Rack / Cabinet, Portable / Hand Held / Mobile
- Instrument Type: Flaw Detection, Corrosion, Material Condition, Other
- Technology: Radiographic / X-ray
-
Supplier: MarShield
Description: , rods, and pellets. This borated polyethylene material has been used around research and test reactors to shield personnel and equipment for neutron radiography and other specialized experiments. It has also been used for shielding of large neutron beam line applications. It has also
- Compound Type: Pellets
- Industry: Other
-
Supplier: ASTM International
Description: specifically for use with X-ray and gamma-ray systems. Other radioscopic systems, such as those employing neutrons, will involve equipment and application details unique to such systems. 1.7 The user of this practice shall note that X-ray energies higher than 320?keV may require
-
Supplier: ASTM International
Description: 1.1 This practice covers test and measurement details for measuring the performance of X-ray and gamma ray radioscopic systems. Radioscopy is a radiographic technique that can be used in (1) dynamic mode radioscopy to track motion or optimize radiographic parameters in real-time
-
Supplier: ASTM International
Description: this practice apply broadly to penetrating radiation radioscopic systems. However, this document is written specifically for use with X-ray and gamma-ray systems. Other radioscopic systems, such as those employing neutrons, will involve equipment and application details unique to such
Find Suppliers by Category Top
Featured Products Top
-
-section for thermal neutrons (~3,840 barns), making it extremely effective at absorbing them. Reaction Mechanism: When boron captures a neutron, it undergoes the reaction: ?^10?B+n→^7 Li+a+(gamma) This converts the neutron into charged (read more)
Browse Polyethylene Resins Datasheets for MarShield
More Information Top
-
http://www-pub.iaea.org/MTCD/publications/PDF/Pub1389_web.pdf
192 Ir fell out of gamma radiography equipment unnoticed, and was later found and handled by three scaffolding workers.
-
http://www-pub.iaea.org/MTCD/publications/PDF/Pub1466_web.pdf
Gamma radiography equipment utilizes a high activity sealed source housed in a shielded exposure device.
-
Durability of Concrete. Second Edition
Gamma radiography equipment can be used in the field to determine the location of reinforcement, density, and perhaps honeycombing in structural concrete units.
-
World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany
2- Specific Authorization for Replacement Sources Authorization should be obtained for each and every replacement source for gamma radiography equip- ments .
-
EXPERIMENTAL‐MECHANICS EQUIPMENT
Gamma Radiography Equipment .
-
Chapter 12—Quality Requirements for Supplies
… Fluores- cent and Dye Penetrant Meth- ods Marine Engineering Regulations and Material Specifications, Subchapter F, Nondestrucitve Examination related to Environmental Testing—Aero- nautical and Associated Equip- ment Testing, Environmental Airbone Electronic and Associated Equipment Military Specification: Gamma Radiography Equipment Manual, Technical, Overhaul Electronic …
-
Calibration of Radiation Sources for Radiography
Four subcommittees concerned specifically with the design and use of X- and gamma radiography equipment exist in American National Standards Committee N43, some of which are just getting started in their activities.
-
Markets for reactor-produced non-fission radioisotopes
In contrast, the lower energy gamma rays and very high specific activity of Ir-192 have allowed much more portable gamma radiography equipment to become widespread.
-
Working safely in gamma radiography. A training manual for industrial radiographers
You will also get more out of the man- ual and the training course if you have worked as a radiographer's assistant using basic gamma ra- diography equipment , especially radiography cameras and survey meters, for at least a month.
-
Emergency preparedness source term development for the Office of Nuclear Material Safety and Safeguards-Licensed Facilities
Autornation I n d u s t r i e s , Inc., manufactures a l i n e o f gamma radiography equipment through i t s instrument d i v i s i o n .