Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Linde North America, Inc.
Description: The Linde Environmental Division is recognized as the worldwide leader in manufacturing calibration gas standards for the environmental monitoring community. The diligent work of Linde's research and development professionals allow us to routinely provide you with the leading
- Applications: Calibration Gas / Gas Standard
-
Supplier: Accuris
Description: Standard Test Method for Analysis of Benzene by Gas Chromatography with External Calibration
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR ANALYSIS OF BENZENE BY GAS CHROMATOGRAPHY WITH EXTERNAL CALIBRATION - INCLUDES STANDARD + REDLINE (PDF)
-
-
Supplier: Accuris
Description: Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration
-
Supplier: Accuris
Description: Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration - INCLUDES STANDARD + REDLINE (PDF)
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of the total nonaromatic hydrocarbons and trace monocyclic aromatic hydrocarbons in toluene, mixed xylenes, and p-xylene by gas chromatography. The purity of toluene, mixed xylenes, or p-xylene can also be calculated. Calibration of
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of the total nonaromatic hydrocarbons and trace monocyclic aromatic hydrocarbons in toluene, mixed xylenes, and p-xylenes by gas chromatography. The purity of toluene, mixed xylenes, or p-xylenes can also be calculated. Calibration
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of the total nonaromatic hydrocarbons and trace monocyclic aromatic hydrocarbons in toluene, mixed xylenes, and p-xylene by gas chromatography. The purity of toluene, mixed xylenes, or p-xylene can also be calculated. Calibration of
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of normally occurring trace impurities in, and the purity of, finished benzene by gas chromatography with external calibration. A similar test method, using the internal standard technique of calibration is Test Method
-
Supplier: Linde North America, Inc.
Description: Whether you are performing Compendium Method TO-15; “Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially Prepared Canisters and Analyzed by Gas Chromatography/Mass Spectrometry (GC/MS)” or Compendium Method TO-17; “Determination of Volatile Organic
- Applications: Calibration Gas / Gas Standard
-
Supplier: Restek
Description: Reference mixtures for ISO/DIS 9377 (German H-53), a gas chromatography/flame ionization detection (GC/FID) method. For GC analysis of total petroleum hydrocarbons (TPH) in water. Environmentally safer than previous methods. Calibration standard available as Diesel
- Applications: Other
- Form: Liquid / Solution
-
Description: degas samples of oil prepared in the laboratory and containing known concentrations of gases ("gas-in-oil standards") and quantitatively analyse the gases extracted. Two methods of preparing gas-in-oil standards are described. For daily calibration
Find Suppliers by Category Top
Featured Products Top
-
When Does a GC Machine Need Calibration Standards with PPB Concentrations? Accurate calibration in gas chromatography transforms good (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
typically achieved through gas chromatography or other analytical techniques. Blending for Precision Following verification, the pure hydrocarbon gases are blended in exact proportions to create the desired hydrocarbon gas calibration mixture. Specialized equipment, which (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
. According to ASTM member Dan Wispinski, laboratory manager at InnoTech Alberta, the new standard is the first to describe the use of the new vacuum ultraviolet (VUV) detector in gas chromatography analysis. Specifically, the standard will soon be published as D8071: Test Method (read more)
Browse Standards and Technical Documents Datasheets for ASTM International -
experiment. The guidance deviates even more when discussing calibration standards, and whether premixed cylinders can match the performance of a purpose-built gas mixer. Regardless of the methodology, all users know accurate calibration standards are essential for optimal gas chromatography (GC (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
time. Such calibration becomes essential in situations where the slightest measurement error could compromise safety, quality, or compliance. Typical use cases include: Detecting trace atmospheric gases such as ozone, carbon monoxide, or volatile organic (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
chromatography, where it is used for air and water quality analysis. What Role Does Calibration Play? Gas chromatography detectors must be calibrated to ensure accurate and precise results. Calibration involves creating a standard solution that contains known (read more)
Browse Datasheets for Environics, Inc. -
Affordable Gas Mixing Solution For over two decades, Environics has been supplying gas mixers to laboratories worldwide, helping users with gas chromatography calibration. Our mixers can generate precise gas calibration standards for research applications requiring specific mixtures. The (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc. -
How to Construct a Calibration Curve for Your GC Machine Calibration curves are essential for ensuring accurate and reliable results in gas chromatography (GC) analyses (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc. -
How On-Site Blending Enhances Gas Chromatography Machine Calibration Gas chromatography (GC) systems are widely used for analyzing chemical compounds (read more)
Browse Mixing and Blending Controllers Datasheets for Environics, Inc. -
gas standards for calibration applications. It is a state-of-the-art system that can be used to generate a range of gas standards and gaseous atmospheres. Follow us on: (read more)
Browse Manifolds and Manifold Systems Datasheets for Environics, Inc.
Conduct Research Top
-
Texas Instruments: Novel Separation Technique for the Analysis of Trace Levels of Atmospheric Contaminants in Inert Semiconductor Process Gases
are separated in a single run via a unique valve switching scheme. A computer-controlled gas blending unit provides multiple levels of dilution of standard gases allowing for the generation of comprehensive calibration curves with a high degree of precision and accuracy. Reproducible detection limits
More Information Top
-
Technological feasibility of biodiesel production from bioaugmented hydrolysate of waste sludge in a municipal wastewater treatment plant
A mixture of 37 reference FAMEs within the range of C15 to C19, includ- ing saturated, mono-unsaturated and polyunsaturated FAMEs, were purchased from Supelco (Bellefonte, PA, USA) and used for the preparation of gas chromatogra- phy (GC) calibration standards .
-
Quadricyclane hydration kinetics in natural waters
Gas chromatography (GC) cal- ibration standard solutions of reactant and product compounds were prepared in CH2Cl2.
-
Determination of dieldrin binding to dissolved organic material in sediment pore water using a reverse‐phase separation technique
An aliquot of the hexane extract was removed and diluted or concentrated asnecessaryto bewithinthelinear range of the gas chromatography (GC) calibration standards .
-
Aerobic biological treatment of waste‐ waters containing dichloromethane
Concentration of DCM present in the liquid phase was determined by gas chromatography via standard calibration curves.
-
Prediction of in vivo metabolic clearance of 25 different petroleum hydrocarbons by a rat liver head-space technique
Gas chromatography and calibration standards All hydrocarbons were analysed on a Shimadzu GC-9A gas chro- matograph (Shimadzu Corporation, Tokyo, Japan) using ¯ame ionization detection after a 0.5-ml sample injection from each vial using a gas-tight syringe.
-
Certification of contents of aromatic hydrocarbons in charcoal tubes – CRM 562
Aliquots of the solutions were analysed twice by gas chromatogra- phy against calibration standards with concentrations close to that from the desorbed material of the tubes.
-
Argon (99.995%) cylinder of 14 L, analytical standard | Sigma-Aldrich
Additional Standards, Analytical Standards, Analytical/ Chromatography , Gas Calibration Standards , Pure Gases, .
-
Carbon Monoxide, Carbon Dioxide, Hydrogen, Methane and Oxygen | Sigma-Aldrich
Additional Standards, Analytical Standards, Analytical/ Chromatography , Gas Calibration Standards , Mixtures, .
-
Carbon dioxide in nitrogen | Sigma-Aldrich
Additional Standards, Analytical Standards, Analytical/ Chromatography , Gas Calibration Standards , Mixtures, .
-
Methane oxidation and pathways of production in a Texas paddy field deduced from measurements of flux, δ l3 C, and δD of CH 4
Further description of. the chromatography and calibrated gas standards used at .:Rice University are given by Sasset al. { 1990, 1991a].
Indicates content that may require registration and/or purchase.