-
Supplier: Pem-Tech, Inc.
Description: Model PT605 on stream monitor / analyzer has been designed for the detection of Hydrogen Sulfide in process streams and in Natural Gas Pipeline. The system is cost effective yet highly accurate and reliable. An industry standard 4-20mA output and three programmable alarm relay contacts
- Number of Channels: 1
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Data Logger, Hazardous Environments, Self Calibration
-
Supplier: Environment One Corporation
Description: Environment One's standard Generator Gas Analyzer (GGA) can also be supplied in a portable configuration. The PGA incorporates the same hydrogen gas sensor/analyzer and system electronics found in our other hydrogen gas purity systems. The PGA is specifically
- Number of Channels: 1
- Operating Temperature: 32 to 125 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Leakage
-
Supplier: Environment One Corporation
Description: E/One's Generator Gas Analyzer (GGA) for hydrogen-cooled generators is a triple-range sensor/analyzer that provides continuous monitoring of gas purity during all phases of generator operation. We've taken a proven monitoring principle — thermal conductivity — and
- Number of Channels: 1
- Operating Temperature: 32 to 158 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Leakage
-
-
Supplier: Siemens Process Instrumentation
Description: integrated interference gas correction The measuring principle of the CALOMAT 62 is based on the measurement of thermal conductivity, a physical quantity that is different for each gas. The signal is determined by a measuring bridge which consists of two electrical resistances in the
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Gas Types: Chlorine (Cl2), Combustible Gas, Hydrogen (H2), Hydrogen Chloride (HCl), Toxic Gas
- Application: Continuous Emissions Monitoring, Process Gas
-
Supplier: ABB Measurement & Analytics
Description: dryer to automatically remove and eliminate effects due to changing moisture in the sample gas flow and a metal oxide scrubber to automatically provide a chemical zero periodically to eliminate the need for “zero gas”. As with all LGR analyzers, the Nitrogen Dioxide
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Nitrogen Dioxide (NO2)
-
Supplier: ABB Measurement & Analytics
Description: LGR’s Hydrogen Sulfide Analyzer (H2S Analyzer) measures H2S in ambient air and in industrial processes with extremely high precision, sensitivity and accuracy. No longer do you have to wait a long time to measure hydrogen sulfide gas with high reliability – LGR’s
- Application: Ambient Air Monitoring, Process Gas
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Hydrogen Sulfide (H2S)
-
Supplier: ABB Measurement & Analytics
Description: LGR's Greenhouse Gas Analyzer (model GGA-24EP) is the world's most advanced instrument for simultaneous measurements of methane (CH4), carbon dioxide (CO2) and water vapor (H2O). Quite simply, no other analyzer provides higher performance. (For details, please see: advantages).
- Application: Ambient Air Monitoring
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrocarbons, Methane (CH4) / Natural Gas, Water Vapor
-
Supplier: Siemens Process Instrumentation
Description: an innovative multi-component gas analyzer which can be equipped with the following sensors: IR detector for IR-active gases, UV photometer for UV-active gases, H2S sensor (electrochemical), O2 sensor (electrochemical or paramagnetic), and used accordingly in numerous
- Measurement Type: %Volume, Trace
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Nitric Oxide (NO), Oxygen (O2), Sulfur Dioxide (SO2), Sulfur Hexafluoride (SF6), Toxic Gas
-
Supplier: RKI Instruments, Inc.
Description: No Description Provided
- Operating Temperature: -40 to 104 F
- Measurement Type: %LEL, %Volume
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Process Sensing Technologies USA
Description: The LD8000 MultiGas is an online gas analyzer to monitor trace N2, O2, H2O, CnHm in Helium. The compact 4U unit has been designed to meet the requirements of the Helium cryogenic installations for online measurement. Features: Compact rackmount enclosure (3U or 4U) to cover up to four
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
Supplier: Siemens Analytical Products
Description: CALOMAT 62 is a thermal conductivity analyzer especially designed for applications in corrosive gases. This allows the concentration of gas components such as Cl2, HCl and NH3 to be measured directly as well as, for example, H2 and N2 in aggressive atmospheres. By this way it
- Operating Temperature: 41 to 113 F
- Measurement Type: %Volume
- Gas Types: Ammonia (NH3), Chlorine (Cl2), Hydrogen (H2), Hydrogen Chloride (HCl)
- Electrical Outputs: Analog Current, Switch
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Laser raman gas analyze?r LRGA-6000 is an advanced equipment that can online measure all the gas composition of most fuel gases, including biogas, syngas, natural gas, producer gas and so on. And with the unique advantages of no consumables, higher accuracy, long
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Combustible Gas, Hydrocarbons, Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4) / Natural Gas, Oxygen (O2), Water Vapor
-
Supplier: Siemens Process Instrumentation
Description: level of economic efficiency. SITRANS SL – easy to handle with contact-free measurement The in-situ SITRANS SL gas analyzer features high operational availability, unique analytical selectivity, and a wide range of possible applications. SITRANS SL permits measurement of a gas
- Response Time: 2 seconds
- Measurement Type: %Volume
- Electrical Outputs: Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Automobile emission gas analyzer Gasboard-5020 is a portable type exhaust gas analyzer, mainly used for measuring exhaust gases of CO, CO2, HC, O2, NO from petro, gasoline, CNG engines, with built-in printer, high accuracy, stable performance and easy operation.
- Response Time: 10.00000000000002 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: ABB Measurement & Analytics
Description: performance validation. The Analyzer has an internal computer (Linux OS) that can store data practically indefinitely on its hard disk drive and send real time data to a data logger via the digital (RS232) or Ethernet outputs. Furthermore, as with all LGR analyzers, this
- Application: Ambient Air Monitoring
- Gas Types: Ammonia (NH3)
- Instrument Type: Analyzer
- Mounting Type: Portable
-
Supplier: CO2Meter.com
Description: concentration range Gain UNLIMITED data logging to a Micro SD Card Included quality Li-ion rechargeable batteries Models CM-1650 - CO2 Welding Gas Analyzer CM-1652 - CO2 + O2 Welding Gas Analyzer Warranty 1-year warranty - see CO2Meter Terms & Conditions
- Gas Types: Carbon Dioxide (CO2)
- Features: Other
- Number of Gases Monitored: Single Gas
-
Supplier: TOC Systems, Inc.
Description: Specific Interference-Free Gas Detection Dual-Wavelength Ratioing Compensates for Drift No Moving Parts Onboard Computer for Accuracy Sapphire Protected Optics Non-Corrosive, Non-ReflectiveHeated Sample Cell Prevents Condensation Detection Technique The NDIR CO 2 detector uses a solid-state,
- Gas Types: Carbon Dioxide (CO2)
- Instrument Type: Detector
- Mounting Type: Fixed
- Application: Process Gas
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 380 Series Tri-Gas Analyzer is designed for monitoring H2 purity in the hydrogen feed to a power generator and to monitor the purging procedure during a generator shut down or start up. The analyzer contains a temperature compensated thermal conductivity (T/C)
- Response Time: 10 seconds
- Operating Temperature: 32 to 120 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Handheld biogas analyzer Gasboard-3200Plus is handheld type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S and optional H2, CO gases, with high accuracy, stable performance and easy carrying features, widely used in anaerobic digestion
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Taylor Dynamometer, Inc.
Description: Taylor Dynamometer is proud to offer a cost-effective emissions analyzer for use with Taylor’s DynPro data acquisition and control system. The system offers superior functionality and an elegantly simple design for a seamless integration with the DynPro system. The Emissions Gas
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova Model 7200-1-F1 flue gas analyzer is specifically designed for use on the flue gases from combustion processes burning gaseous fuels.Sample Gas is drawn into the analyzer from the sampling probe, then pumped through a condensate removal system. Any condensate
- Response Time: 20 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 5 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O by
- Operating Temperature: 23 to 113 F
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Self Calibration
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online biogas analyzer Gasboard-3200 is a rack type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S with high accuracy, stable performance, can be easily integrated with biogas analysis system, widely used in anaerobic digestion biogas, waste water
- Response Time: 15 seconds
- Operating Temperature: 32 to 122 F
- Operating Humidity: 0 to 95 %
- Measurement Type: %Volume, Trace
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 8000 series has been designed for the continuous monitoring of pre-cleaned gases from a blast furnace or other high intensity, continuous industrial processes. The analyzer measures up to four gases simultaneously - O2, CO, CO2, and H2, the ranges of which are shown below.
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
-
Supplier: Siemens Process Instrumentation
Description: The SIPROCESS UV600 is an extractive UV gas analyzer that can measure up to three components simultaneously. SIPROCESS UV600 with state of-the-art electronics and software, has the interfaces required for remote monitoring from a network as well as connecting to a process control
- Operating Temperature: 41 to 113 F
- Instrument Type: Analyzer
- Gas Types: Combustible Gas, Hydrogen Sulfide (H2S), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Sulfur Dioxide (SO2), Toxic Gas
- Application: Continuous Emissions Monitoring, Process Gas
-
Supplier: Fuji Electric Corp. of America
Description: Insertion type offers high-speed measurement. Long-term stability and low maintenance. ZSS Laser Gas Analysers for : waste incinerators, district heating and industrial boilers, chemical plant. NH3 – HCI – CO – O2 – CO2 – CH4
- Instrument Type: Analyzer
- Gas Types: Carbon Dioxide (CO2), Hydrogen Chloride (HCl), Methane (CH4) / Natural Gas, Oxygen (O2)
- Application: Confined Space Monitoring
- Mounting Type: Fixed
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 5000 Series Portable Flue Gas analyzer has been designed for accuracy, reliability, ease of use and ease of service, providing a detailed analysis of flue gas composition. The 5000 uses customer replaceable sensors which respond quickly to the O2, CO2, SO2, CO, and NOx
- Response Time: 30 seconds
- Operating Temperature: 32 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Owlstone Inc.
Description: Lonestar is a portable gas analyzer that can detect a broad range of analytes at part per billion concentrations, with high selectivity in just a few seconds.
- Operating Temperature: 41 to 104 F
- User Controls: Computer Interface
- Water Quality Parameters: Conductivity / Dissolved Solids, pH
- Instrument Specific Features: Controller Functionality
-
Supplier: Fuji Electric Corp. of America
Description: NO2 to NO converter for NOx measurements. NOx Converters are utilized in combustion plants, incineration, steel plants, furnace control, CEMS, research labs, and more.
- Application: Confined Space Monitoring
- Mounting Type: Fixed
- Gas Types: Nitric Oxide (NO), Nitrogen Dioxide (NO2)
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This hybrid system is the most cost effective solution to meet the measurement needs in marine applications. Key Features/Benefits: Measure up to 10 gases simultaneously Ambient environments of up to 70°C (158°F) and gas temperatures of 190°C (374°F) Single and dual path options give ppb to %
- Operating Temperature: -4 to 158 F
- Operating Humidity: 10 to 95 %
- Number of Channels: 6
- Measurement Type: %Volume, Trace
-
Supplier: Process Sensing Technologies USA
Description: The MoGas Medical gas analyzer range is a wall or surface mounting instrument designed for use on Medical Oxygen Generation systems for checking the purity of the Oxygen produced. The MO2GA93 range is specifically designed for Medical Oxygen Generation systems producing Oxygen at 93%
- Operating Humidity: 15 to 95 %
- Measurement Type: %Volume, Trace
- Instrument Type: Analyzer
- Gas Types: Oxygen (O2)
-
Supplier: LAND
Description: Developed based on AMETEK Land’s decades of experience in carbon monoxide monitoring solutions, the Model 9100 provides the direct, continuous, cross-stack CO measurement and fast-response coverage essential to efficient combustion control in boilers.
- Response Time: 90 seconds
- Operating Temperature: 32 to 95 F
- Measurement Type: %LEL, Trace
- Electrical Outputs: Analog Current
-
Supplier: COSA Xentaur Corporation
Description: probe remains in place, thus no disruption of the process is required. The sample gas diffuser protects the sensor from exposure to sample gas contaminants and a built in verification port exposes the sensor to calibration gas. Calibrations can be performed manually or
- Operating Temperature: -4 to 140 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
-
Supplier: Panametrics
Description: The new XMTCpro is a compact, rugged, online thermal conductivity transmitter that measures the concentration of binary gas mixtures including hydrogen, carbon dioxide, methane, helium and many others. Featuring real-time error detection and enhanced signal measurement for fastest response,
- Response Time: 20 seconds
- Operating Temperature: -4 to 122 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current
Find Suppliers by Category Top
Featured Products Top
-
CO2Meter Inc., a worldwide leader in gas detection and safety monitoring, released its new portable CO2 welding gas analyzer that verifies correct CO2 concentrations in welding gas mixes. The highly anticipated CM-1650 measures mixed cylinder gas or blended gas at a mixer to ensure the (read more)
Browse Data Loggers and Data Recorders Datasheets for CO2Meter.com -
ensures the proper handling and storage of flammable gases, vapor, and liquids to prevent ignition. With the GM32 in-situ gas analyzer now certified with this approval, this ensures the effective and safe measurement of SO2, NO, NO2, and (read more)
Browse Gas Instruments Datasheets for SICK -
The revolutionary analyzer for natural gas quality monitoring We are pleased to announce the launch of our new Sensi+, the single and compact analyzer that detects simultaneously multiple gas contaminants in natural gas stream. It provides continuous measurements of H2S (read more)
Browse Gas Instruments Datasheets for ABB Measurement & Analytics -
Semiconductor manufacturing is a complex and specialized process with numerous applications for precision gas and pressure control. Learn more about how Clippard's engineering team combined our DR-2 regulator and analytical valve with a special manifold to create a precision flow (read more)
Browse Gas Valves Datasheets for Clippard -
Pressure sensors are used in many applications. But sometimes the standard version does not offer an ideal solution. The following example shows how E+H Sensors&Components can help to tailor sensors exactly to the customers application. The J22 TDLAS is a gas analyzer that (read more)
Browse Pressure Sensors Datasheets for Endress + Hauser – Sensors & Components -
commissioning and maintenance as the set points and dead bands are field programmable, saving more than 70% in maintenance time compared to a mechanical switch. The 1XSWLL model operates on the same 2 wires as a mechanical switch enabling (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
minimal commissioning and maintenance as the set points and dead bands are field programmable, saving more than 70% in maintenance time compared to a mechanical switch. The 1XSWLL model operates on the same 2 wires as a mechanical switch enabling (read more)
Browse Thermal Switches and Thermal Protectors Datasheets for United Electric Controls Company -
AII’s portable O? analyzer range provides accurate oxygen measurement in a variety of portable and field-based applications. Designed for ease of use and dependable performance, these analyzers support oxygen verification wherever mobility is required (read more)
Browse Gas Instruments Datasheets for Analytical Industries Inc. -
A Quick Guide to Calibrating CEM Gas Analyzers Calibrating Continuous Emissions Monitoring (read more)
Browse Manifolds and Manifold Systems Datasheets for Environics, Inc. -
The Palm O? RD Analyzer is a handheld oxygen analyzer designed to provide accurate and repeatable oxygen measurement across a range of gas applications. Its portable design makes it suitable for field use, maintenance checks, and quality verification (read more)
Browse Gas Transmitters Datasheets for Analytical Industries Inc.
More Information Top
-
Federal Register > Monday, April 21, 2008 > [73 FR 21418] Federal Implementation Plan for the Billings/Laurel, MT, Sulfur Dioxide Area
(E) For all periods that the range of the flare or any pilot or purge gas volumetric flow rate monitor(s), any flare total sulfur analyzer(s), or any pilot or purge gas H2S analyzer (s) is exceeded, the written report shall…
-
Code of Federal Regulations > Title 40 - Protection of Environment > Clean Air Act / Air Programs (CAA) > [40 CFR Part 52] Approval and Promulgation of Impleme...
(E) For all periods that the range of the flare or any pilot or purge gas volumetric flow rate monitor(s), any flare total sulfur analyzer(s), or any pilot or purge gas H2S analyzer (s) is exceeded, the written report shall…
-
JZUS - Journal of Zhejiang University SCIENCE
A SO2 and H2S gas analyzer (MOT400, Shenzhen Keernuo Technology Co. Ltd., China) connected to the reactor outlet qualitatively detected the by-products of the side reactions.
-
Occurrence of the Bunsen side reaction in the sulfur-iodine thermochemical cycle for hydrogen production
A SO2 and H2S gas analyzer (MOT400, Shenzhen Keernuo Technology Co. Ltd., China) connected to the reactor outlet qualitatively detected the by-products of the side reactions.
-
Procedure for Measuring Low Concentrations of H2 and H2 S Above a Water Surface
This procedure became possible due to devel- opment of highly sensitive H2 and H2S gas analyzers [1, 2].
-
Federal Register > Wednesday, September 12, 2012 > [77 FR 56422] Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum Refi...
Comment: One commenter supported the proposed amendment revising the span value for fuel gas H2S analyzers to match the span requirements in 40 CFR part 60, subpart J, stating this will save time and money.
-
A New Lab for Testing Biofiltration for Advanced Life Support
Filters were installed prior to the NH3 and H2S gas analyzers to protect the analyzers from particulate matter.
-
Soil CO 2 emissions as a proxy for heat and mass flow assessment, T aupō V olcanic Z one, N ew Z ealand
…SystemsVR accumulation chamber and LICOR LI-820 infrared gas analyzer for CO2 (maximum concentration 20,000 ppm) following the recommendations of Welles et al. [2001]. uH2S was measured using the same chamber and a TOX05 H2S gas analyzer (maximum concentra- tion 20…
-
Correlation between levels of exhaled hydrogen sulfide and airway inflammatory phenotype in patients with chronic persistent asthma
The exhaled air was collected in fluoropolymer gas sampling bags (Hyde Technology Co., Ltd., Dalian, China), and H2S levels were evalu- ated using a 4170 portable H2S gas analyzer (INTERSCAN, Simi Valley, CA, USA) following the manufacturer’s instructions.
-
Distribution of Hydrogen Sulphide in the Buzzard Field
In the short term a number of H2S gas analysers have been added to the 2nd stage and test .
Indicates content that may require registration and/or purchase.