Supplier: Kikusui America, Inc.
Description: The 149-10A is a digital voltmeter that can measure high voltages up to a ±10kV AC and DC at high accuracy. Its high input impedance (1000M ohm) make it suitable for measurement of high impedance voltage circuits. Since it has a high
- DC Voltage Range: 0.5 to 10,000 volts
- AC Voltage Range: 0.5 to 10,000 volts
- Display Digits: 4 Digits, Plus 1/2 Digit
- Measurement Type: AC / DC
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: The DMS-30PC Series is a broad line of self-contained, fully operational, 3½ digit voltmeters with large, easy-to-read LED displays. The 0.56"(14.2mm) high LED's are available in a wide variety of colors including red, orange, amber, yellow, green, aqua, blue-green, and super-blue. A
- Number of Digits: 3.5
- Width: 64.77 mm
- Height: 32.258 mm
- Operating Temperature: 32 to 140 F
-
Supplier: ValueTronics International, Inc.
Description: The 6263B is a 200 Watt DC Power Supply from AHP. Supplies DC Voltage and Current to test, design, and troubleshoot electric and electronic circuits. Applications include Burn In, QA, ATE, Research, Design, and Education to name a few. Additional Features: Voltage: 20V Current: 10A
- DC Output Power: 200 watts
- Type: DC Power Supply
-
-
Supplier: ValueTronics International, Inc.
Description: and compact design For output voltage calibration of withstanding voltage testers and insulation testers The Kikusui 149-10A is a digital voltmeter that can measure high voltages up to a ±10kV AC and DC at high accuracy. Its high input impedance (1000M ohm)
-
Supplier: Krohn-Hite Corporation
Description: Our DC Source/Calibrators are designed for a typical applications such as the design, check and calibration of high speed, high resolution A/D converters; design and certification of high speed data logging and process control systems; calibration of digital
- DC Voltage Range: 0.000000001 to 1 volts
- Operating Temperature: 32 to 122 F
- User Interface: Analog Front Panel
- Calibration Signal: DC Voltage
-
Supplier: Panel Components & Systems, Inc.
Description: Laureate™ DC voltage and current panel meters with a DC signal conditioner board combine high accuracy with high read rate and a wide range of isolated output options for computer interface and control. Accuracy is 99.99% of full scale ±1 count. Used as a direct-reading
- Display Colors: Green, Yellow
- Display Technology: LED
- Display Type: Numeric Display
-
Supplier: ValueTronics International, Inc.
Description: The 80K-15 is a probe from Fluke. Probes can use pulse waveforms to test components without removing them from circuits with in-circuit capabilities. Additional Features: The 80K-15 is a high voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter
-
Supplier: L-com, Inc.
Description: up to 8000V. The Model 5233 is ideal for electrical installers, electricians and heating or air-conditioning specialists. Features Ohmmeter, Continuity test with buzzer, Diode test and Capacitance functions 6000-count backlit display + 61 segment bargraph AC/DC voltmeter with
-
Supplier: ValueTronics International, Inc.
Description: extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts peak AC or DC Overvoltage Category I. This means the probe can only be used to make measurements on energy limited circuits within equipment. Examples include high voltage within televisions or
- Voltage Rating: 40,000 volts
- Probe Type: Current, Voltage
-
Supplier: Laurel Electronics LLC
Description: panel meters with a DC signal conditioner board. They combine high accuracy with high read rate and a wide range of (isolated) Plug-and-Play output option boards for computer interface and control. DC meter Accuracy of 0.01% of reading ± 2 counts. DC
- Number of Digits: 5
- Width: 118.872 mm
- Height: 62.23 mm
- Depth: 143.256 mm
-
Supplier: Rohde & Schwarz USA, Inc.
Description: TheR&S®NGMO analyzer/power supply is more than just a simple power supply for test and measurement applications. This is shown by its advanced features: Accurate high-speed voltage source Programmable DC load Precise digital voltmeter Transient recorder Simple squarewave
- DC Output Voltage: -5 to 25 volts
- Type: DC Power Supply
-
Supplier: Laurel Electronics LLC
Description: transmitter for DC voltage and current inputs: DC voltmeter operation (selected by jumpers) provides and six full-scale DC voltage ranges from ±200.00 mV with 10 mV resolution to ±600.0V with 100 mV resolution. The 200.00 mV and 2.0000V ranges provide a high input
- Operating Temperature: -40 to 158 F
- Outputs: Current Loop (e.g., 4-20 mA), Ethernet, Voltage
- Features: DC Current, DC Voltage
- Form Factor: DIN Rail
-
Supplier: Laurel Electronics LLC
Description: and RS232/RS485 output transmitter for DC voltage and current inputs: DC voltmeter operation (selected by jumpers) provides and six full-scale DC voltage ranges from ±200.00 mV with 10 mV resolution to ±600.0V with 100 mV resolution. The 200.00 mV and 2.0000V ranges
- Operating Temperature: -40 to 158 F
- Outputs: Current Loop (e.g., 4-20 mA), Voltage
- Features: DC Current, DC Voltage
- Form Factor: DIN Rail
-
Description: This standard may apply, with suitable exceptions, to instruments constructed for special requirements - for example, ultrasensitive dc microammeters, high-resistance voltmeters, thermomilliammeters, thermovoltmeters of the vacuum-couple type, and instruments with special and
-
Supplier: Mile-X Equipment, Inc.
Description: apart. 6043 AC/DC Current Sensing Inductive pickup INCLUDED Unique curved carbon discs assure maximum contact, fewer hot spots, smoother operation and longer life. 10-meg ohm input impedance for today’s high tech systems Convenient heavy-duty tilt back cart with 8 inch wheels
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: ±200mV, ±2V ±20V or ±200V. Input impedance is a minimum 800k. CMRR is typically 86dB (dc to 60Hz), and CMV is ±2V. Input overvoltage protection (on the non-inverting input) is ±250V. Devices are fully calibrated at the factory to an accuracy of ±1 count (±0.05% of full scale range) and
- Number of Digits: 3.5
- Analog Input Channels: 1
- Width: 46.3804 mm
- Height: 32.512 mm
Find Suppliers by Category Top
Featured Products Top
-
a dual N-channel enhancement mode with matched transistor pairs, which reduces offset voltage and ensures differential thermal response. Key attributes of the device include high input impedance of 1014?, low input capacitance, and a negative current temperature coefficient. It (read more)
Browse Metal-Oxide Semiconductor FET (MOSFET) Datasheets for Advanced Linear Devices, Inc. -
High performance DC to 8GHz 10W RF coaxial dummy load termination adopts premium internal resistance material, features ultra low VSWR, good heat dissipation and stable 50 ohm impedance. It can effectively absorb excess radio frequency power, widely used in RF signal testing, wireless (read more)
Browse RF Terminations Datasheets for 5o.com -
Model NO.: UIYCA100AN18A40 Type: RF Coaxial Attenuator Brand Name: UIY Freq. Range (GHz): DC-18GHz Attenuation Value(dB): 60dB Attenuation Tolerance (read more)
Browse RF Attenuators Datasheets for UIY Inc. -
Consumption – 150mA current rating with minimal DC resistance (1.88Ω max) reduces energy loss. High Durability – Designed for long-term reliability in telecommunication (read more)
Browse Uncategorized Products Datasheets for Win Source Electronics -
High-Performance Dual-Channel RF Rotary Joint (read more)
Browse RF Rotary Joints Datasheets for JiuJiang Ingiant Technology Co., Ltd. -
one 12 V power supply fit in a single 2U 19” rack mountable enclosure. The controls of the power modules are on the front panel. The back panel contains SHV-type plugs for the high voltage output and 4 mm banana jacks to easy monitor the control voltage with external voltmeter. Low-RPM 60 (read more)
Browse Power Supplies Datasheets for Daitron Co., Ltd. -
, Function/Arbitrary Waveform Generator, Spectrum Analyzer, Digital Voltmeter, High-Precision Frequency Counter, Protocol Analyzer, Jitter/Eye Analyzer and Power Analyzer. This oscilloscope offers a cost-effective solution for advanced users. Main Features of the MSO7000X Series (read more)
Browse Oscilloscopes Datasheets for Uni-Trend US -
0.4 nV/√Hz Switchable AC/DC-Coupling Local and Remote Control Input Impedance up to 1 TΩ FEMTO's new DLPVA-101 Voltage Amplifiers join a long line of (read more)
Browse Instrumentation Amplifiers Datasheets for Electro Optical Components, Inc. -
500Ω impedance at 100MHz attenuates common-mode noise in high-speed signal and power circuits. High Current Capability: Rated for continuous 4A current with low (read more)
Browse Inductors, Coils, and Chokes Datasheets for Win Source Electronics -
for testing, signal routing, and multi-device communication. The adapter has precision-machined connections and a 50 Ω impedance for low signal loss and consistent RF performance. Built with high-quality metal, it provides durability, great electrical (read more)
Browse RF Adapters Datasheets for Eteily Technologies India Pvt. Ltd.
More Information Top
-
Recent Advances in AC-DC Transfer Measurements Using Thin-Film Thermal Converters
Existing measurement systems for ac-dc comparison employing high impedance dc voltmeters are filly capable of performing calibrations with the new thermoelements.
-
Random sampling of an AC source: A tool to teach probabilistic
observations
This volt- age can be measured by a high impedance DC voltmeter .
-
An integrating system for measuring the energy delivered by a flashlamp-driven dye laser ultraviolet radiation source
We also use a high impedance DC voltmeter so that we may continuously monitor theamplitude of the signal beingfedinto . theintegrator.Thevoltmeter . is not an essential component, but we find it very useful in monitoring and operating our laser since the DC amplifier …
-
Field generator for a monopole mass spectrometer
5 With a high impedance dc voltmeter connected to the output RV2 is adjusted until the desired level of superimposed dc is obtained. .
-
Calibration of antenna factor of a tuned dipole using two antenna method, NIST method and a proposed reference antenna
using a high impedance dc voltmeter after filtering it using a low pass RC filter.
Indicates content that may require registration and/or purchase.