-
Supplier: Fairview Microwave Inc.
Description: Fairview Microwave waveguide to coaxial adapter (also known as a waveguide coaxial transition) SMW51AC is manufactured with a right angle design. Right angle waveguide to coaxial adapter / transition has a waveguide size of WR-51 and UBR180 flange. This
- Adapter Type: Coaxial / Waveguide
- Frequency Range: 15000 to 22000 MHz
- VSWR: 1.25 :1
-
Supplier: Fairview Microwave Inc.
Description: Fairview Microwave waveguide to coaxial adapter (also known as a waveguide coaxial transition) SMW75ACC is manufactured with a right angle design. Right angle waveguide to coaxial adapter / transition has a waveguide size of WR-75 and square cover flange.
- Adapter Type: Coaxial / Waveguide
- Frequency Range: 10000 to 15000 MHz
- VSWR: 1.25 :1
-
Supplier: Fairview Microwave Inc.
Description: Fairview Microwave waveguide to coaxial adapter (also known as a waveguide coaxial transition) FMWCA1071 is manufactured with a end launch design. End launch waveguide to coaxial adapter / transition has a waveguide size of WR-62 and square cover flange.
- Adapter Type: Coaxial / Waveguide
- Frequency Range: 12400 to 18000 MHz
-
-
Supplier: Fairview Microwave Inc.
Description: Fairview Microwave waveguide to coaxial adapter (also known as a waveguide coaxial transition) FMWCA1028 is manufactured with a right angle design. Right angle waveguide to coaxial adapter / transition has a waveguide size of WR-62 and square cover flange.
- Adapter Type: Coaxial / Waveguide
- Frequency Range: 12400 to 18000 MHz
-
Supplier: QuinStar Technology, Inc.
Description: QuinStar Technology’s QWA series waveguide to coax adapters allow an efficient method of transition from rectangular waveguide to a coaxial connector. Full waveguide band adapters are available from 12.4 to 110 GHz in Ku through W bands.
- Component Type: Transition Adapters
- Operating Frequency Range: 12.4 to 110 GHz
-
Supplier: Molex Signal Tech Industrial Ltd.
Description: The SpaceNXT™ Ku-Band High Power family of passive waveguide components are part of Smiths Interconnect’s overarching initiative to create a broad range of readily accessible space qualified waveguide Isolators, Circulators, Terminations, transitions, Hybrids and couplers
- Waveguide Material: Aluminum
Find Suppliers by Category Top
Featured Products Top
-
Professional 11.9-18GHz Ku Band WR62 BJ140 Waveguide to Coaxial Adapter, a high-reliability transition component designed to facilitate seamless signal transfer between WR62 waveguide systems and coaxial cables (read more)
Browse RF Waveguide Components Datasheets for 5o.com -
, covering both X Band and Ku Band applications. This precision-engineered adapter features a robust construction with a square flange design, ensuring secure and stable connections between waveguide systems and coaxial cables. Designed for radar (read more)
Browse RF Waveguide Components Datasheets for 5o.com -
The UIYWTCWR90A82T125SF Waveguide to Coaxial Adapter is a high-performance microwave device, designed specifically for the 8.2-12.5GHz frequency band to efficiently convert waveguide signals to coaxial signals. With its exceptional electrical performance and reliability, it is widely used (read more)
Browse Waveguide-to-Coaxial Adapters Datasheets for UIY Inc. -
WR90 (BJ100) X Band Waveguide to Coaxial Adapter operating 8.2-12.4GHz with industry-leading 0.2dB maximum insertion loss, low VSWR <1.15, 50Ω impedance, SMA/N female connector options. Precision machined, rugged, -55? to +85? for radar, satellite communications, 5G millimeter-wave, and (read more)
Browse RF Waveguide Components Datasheets for 5o.com -
Maury offers a full range of in-series and between-series metrology-grade RF coaxial and waveguide adapters in most popular connector types, including 1.85mm, 2.4mm (Q), 2.92mm (K), 3.5mm, 7mm, 14mm, type N, (50 and 75 ohm), BNC (50 and 75 ohm) TNC, AFTNC, TNCA, LPC/OSP, and (read more)
Browse RF Adapters Datasheets for Maury Microwave -
loads and shorts in 1.85mm, 2.4mm, 3.5mm and type N 50 ohm. In-Series and Between-Series coax-to-coax adapters for these connector types are also available, and waveguide-to-coax adapters in the most common waveguide bands will be available soon. Look for the Maury (read more)
Browse Datasheets for Maury Microwave -
, 2.4mm, 3.5mm and type N. In-Series and Between-Series coax-to-coax adapters for these connector types are also available, and waveguide-to-coax adapters in the most common waveguide bands will be available soon. Look for the Maury TactiCal™ label when you (read more)
Browse Calibration Instruments Datasheets for Maury Microwave -
interface is precision-machined to meet industry standards, ensuring a tight, secure connection with standard WR284/G waveguide components—eliminating the need for custom adapters or modifications. The compact, robust design allows for easy integration into existing RF systems, even in space (read more)
Browse RF Rotary Joints Datasheets for JiuJiang Ingiant Technology Co., Ltd.
More Information Top
-
Ku-band EMI shielding effectiveness and dielectric properties of Polyaniline-Y2 O3 composites
Thus, the processed polyaniline composite samples are fixed in between the Ku band waveguide adapter and con nected to vector network analyzer (Agilent technolo gies, model E8362B 10 MHz to 20 GHz; USA).
-
Analysis of a coaxial-to-waveguide adaptor including a discended probe and a tuning post
One of the task was to design a Ku - band coaxial-to- waveguide adaptor .
-
Reflection ellipsometry for in-situ measurements of complex permittivity and thickness of a single-layer material at microwave frequencies : theory and experim...
The antennas are mounted on their own column by a rectangular mechanical adapter which allows to consider different waveguides (X and Ku - bands at present) ; this adapter fills the rotating system to allow the rotation of the antenna around its horizontal axis.
-
Reflection ellipsometry for in‐situ determination of complex permittivity and thickness of a single‐layer material at several angles of incidence and frequenci...
The antennas are mounted on their own columns by a rectangular mechanical adapter which allows us to consider dif- ferent waveguides (X and Ku - bands in this case); this adapter fills the rotating system in order to allow rotation of the antenna …
-
Negative Group Velocity and Spin-Flip in Microwave Adaptors
… dimen- sions are 15.8 mm · 7.9 mm the corresponding circular waveguide has an inside … For com- parison we have investigated the same quantities with Ku - band adaptors and L = 0.2 m.
-
Analysis and modeling of a high-temperature superconducting floating resonant strip in waveguide
The adhesive tape exhibited low loss (less than 0.5 dB) at both room and LN2 temperatures across the bandwidth of X and Ku - band waveguide . … the test fixture via coax, the waveguide actually consisted of waveguide to coax adapters for the respective …
-
Giant negative group time delay by microwave adaptors
… dimensions are 15.8 mm · 7.9 mm, the corre- sponding circular waveguide has an inside … For comparison we have investigated the same quantities with Ku - band adaptors and L = 0.2 m.
-
Effects of extreme surface roughness on 3D printed horn antenna
Device and manufacturing: Two horn antennas were designed in SolidWorks to work in the Ku - band (12–15 GHz) region and saved as industry standard STL files. Only the horn was printed; the coax-to- waveguide adaptor was not.
-
Using Microwave Measurements to Detect Moisture in Asphaltic Concrete
The focused antenna isconnected to one port of the S-parameter test- set using a circular-to-rectangular waveguide transition. rectan- gular waveguide to coaxial adapter . and coaxial cables. … diffraction effects can be ne- glected if the diameter of the specimen is greater than three times the size of the spot-focusing horn lens antenna 1191.There- forethe measurements were dooe in t k Ku frequency band ( 12.4 to 18GHz).
-
A calibration technique for measurements of reflection from an open-ended waveguide
The accuracy ofthis calibration can be improved by using a waveguide isolator or attenuator between the adapter and the directional coupler. The admittance of the open-ended waveguide has been measured using this calibration technique at the X band and Ku band .
Indicates content that may require registration and/or purchase.